Evaluation of Regeneration Processes for Filtering Facepiece Respirators in Terms of the Bacteria Inactivation Efficiency and Influences on Filtration Performance
Source abstract
Abstract
The regeneration of filtering facepiece respirators (FFRs) is of critical importance because of the severe shortage of FFRs during large-scale outbreaks of respiratory epidemics, such as COVID-19. Comprehensive experiments regarding FFR regeneration were performed in this study with model bacteria to illustrate the decontamination performance of the regeneration processes. The results showed that it is dangerous to use a contaminated FFR without any microbe inactivation treatment because the bacteria can live for more than 8 h. The filtration efficiency and surface electrostatic potential of 75% ethanol-treated FFRs were significantly reduced, and a most penetrating particle size of 200 nm was observed. Steam and microwave irradiation (MWI) showed promising decontamination performances, achieving 100% inactivation in 90 and 30 min, respectively. The filtration efficiencies of steam-treated FFRs for 50 and 100 nm particles decreased from 98.86% and 99.51% to 97.58% and 98.79%, respectively. Ultraviolet irradiation (UVI) effectively inactivated the surface bacteria with a short treatment of 5 min and did not affect the filtration performance. However, the UV dose reaching different layers of the FFP2 mask sample gradually decreased from the outermost layer to the innermost layer, while the model bacteria on the second and third layers could not be killed completely. UVI+MWI and steam were recommended to effectively decontaminate the used respirators and still maintain the respirators' filtration efficiency. The present work provides a comprehensive evaluation for FFR regeneration in terms of the filtration efficiencies for 50-500 nm particles, the electrostatic properties, mechanical properties, and decontamination effects.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Infection Control and Ventilation · Burn Injury Management and Outcomes · Aerosol Filtration and Electrostatic Precipitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Filter Test Center, Northeastern University, Shenyang, Liaoning CN-110819, China
Institute of Environmental Engineering, ETH Zürich, Zürich, CH-8093, Switzerland
Lab of Advanced Analytical Technologies, Empa, Dübendorf, CH-8600, Switzerland
Funding
Ministry of Science and Technology of the People's Republic of China · China Scholarship Council · Innosuisse - Schweizerische Agentur f?r Innovationsf?rderung · Center for Filtration Research, University of Minnesota · Liaoning province
References (77)
Show source-provided references
1. 10.1021/acsnano.0c0282310.1021/acsnano.0c02823 ↗
2. 10.1021/acsnano.0c0243910.1021/acsnano.0c02439 ↗
3. 10.1021/acsnano.0c0340210.1021/acsnano.0c03402 ↗
4. 10.14744/ejmo.2020.1222010.14744/ejmo.2020.12220 ↗
5. 10.1056/NEJMra01267010.1056/NEJMra012670 ↗
6. 10.1111/j.1600-0668.2009.00603.x10.1111/j.1600-0668.2009.00603.x ↗
7. Zhou, Y. R. The Global Effort to Tackle the Coronavirus Face Mask Shortage. https://theconversation.com/the-global-effort-to-tackle-the-coronavirus-face-mask-shortage-133656 (accessed 2020-03-14).
8. 10.1021/acsnano.0c0359710.1021/acsnano.0c03597 ↗
9. 10.1021/acsnano.0c0325210.1021/acsnano.0c03252 ↗
10. 10.1080/15459624.2014.90295410.1080/15459624.2014.902954 ↗
11. National Institute for Occupational Safety and Health (NOISH). Recommended Guidance for Extended Use and Limited Reuse of N95 Filtering Facepiece Respirators in Healthcare Settings. Centers for Disease Control and Prevention (CDC); 2020; https://www.cdc.gov/niosh/topics/hcwcontrols/recommendedguidanceextuse.html (accessed 2020-09-16).
12. National Center for Immunization and Respiratory Diseases (NCIRD), Division of Viral Diseases. Implementing Filtering Facepiece Respirator (FFR) Reuse, Including Reuse after Decontamination, When There Are Known Shortages of N95 Respirators. N95 Respirators: Decontamination & Reuse. Centers for Disease Control and Prevention (CDC); 2020. https://www.cdc.gov/coronavirus/2019-ncov/hcp/ppe-strategy/decontamination-reuse-respirators.html (accessed 2020-09-16).
13. 10.21037/jtd.2018.03.10310.21037/jtd.2018.03.103 ↗
14. 10.1016/j.ajic.2006.10.01410.1016/j.ajic.2006.10.014 ↗
15. FDA ‘OKs’ Healthcare Workers to Reuse N95 Face Masks; Here’s How They’re Being Cleaned. https://wwmt.com/news/local/fda-oks-healthcare-workers-to-reuse-n95-face-masks-heres-how-theyre-being-cleaned (accessed 2020-03-31).
16. 10.4265/bio.11.14710.4265/bio.11.147 ↗
17. 10.1046/j.1365-2672.2002.01540.x10.1046/j.1365-2672.2002.01540.x ↗
18. 10.1016/j.jes.2017.07.00610.1016/j.jes.2017.07.006 ↗
19. Rogers W. J. · 2012 · 2010.1533/9780857096265.20 ↗
20. 10.1128/AEM.01790-0810.1128/AEM.01790-08 ↗
21. Viscusi D. J. · Ann. Occup. Hyg. · 2009 · 53 · 815
22. Viscusi D. J. · J. Int. Soc. Respir. Prot. · 2007 · 24 · 93
23. Martella, M. S.; Ross, A.; Le, C. Research to Mitigate a Shortage of Respiratory Protection Devices During Public Health Emergencies (Report to the FDA No. HHSF223201400158C). Applied Research Associate, Inc. https://www.ara.com/sites/default/files/MitigateShortageofRespiratoryProtectionDevices_2.pdf (accessed 2020-04-30).
24. Lore M. B. · Ann. Occup. Hyg. · 2012 · 56 · 92
25. Lowe, J. J.; Paladino, K. D.; Farke, J. D.; Boulter, K.; Cawcutt, K.; Emodi, M.; Gibbs, S.; Hankins, R.; Hinkle, L.; Micheels, T.; Schwedhelm, S.; Vasa, A.; Wadman, M.; Watson, S.; Rupp, M. E. N95 Filtering Facepiece Respirator Ultraviolet Germicidal Irradiation (UVGI) Process for Decontamination and Reuse. https://www.nebraskamed.com/sites/default/files/documents/covid-19/n-95-decon-process.pdf (accessed 2020-04-10).
26. 10.1016/j.ajic.2018.02.01810.1016/j.ajic.2018.02.018 ↗
27. 10.1177/153567602091993210.1177/1535676020919932 ↗
28. EU CDC. Cloth Masks and Mask Sterilisation as Options in Case of Shortage of Surgical Masks and Respirators. https://www.ecdc.europa.eu/sites/default/files/documents/Cloth-face-masks-in-case-shortage-surgical-masks-respirators2020-03-26.pdf (accessed 2020-03-26).
29. Schweitzer P. A. · 2006 · 1
30. 10.1016/j.polymer.2018.05.02310.1016/j.polymer.2018.05.023 ↗
31. 10.1016/j.msea.2010.01.01410.1016/j.msea.2010.01.014 ↗
32. Motyl E. · Fibers Text. East. Eur. · 2006 · 14 · 59
33. 3M Steri-Vac Sterilizer/Aerator GS Series. [http://multimedia.3m.com/mws/media/1057877O/3m-steri-vac-ethylene-oxide-sterilization-systems.pdf?fn=70-2011-5626-5%20Steri-Vac%20Sterili]. 3M Health Care Infection Prevention Division, St. Paul, MN, USA, 2020.
34. 10.1007/s11051-014-2417-z10.1007/s11051-014-2417-z ↗
35. 10.1080/1047322005007561710.1080/10473220050075617 ↗
36. 10.1093/annhyg/men01910.1093/annhyg/men019 ↗
37. 10.1080/15459624.2010.51391010.1080/15459624.2010.513910 ↗
38. Battelle. Final Report for the Bioquell Hydrogen Peroxide Vapor (HPV) Decontamination for Reuse of N95 Respirators; U.S. Food and Drug Administration, 2016.
39. 10.1017/ice.2020.210.1017/ice.2020.2 ↗
40. 10.1016/j.jaerosci.2007.12.00510.1016/j.jaerosci.2007.12.005 ↗
41. 10.4315/0362-028X-68.11.236210.4315/0362-028X-68.11.2362 ↗
42. 10.1163/156856195X0021110.1163/156856195X00211 ↗
43. 10.1002/polb.1994.09032070910.1002/polb.1994.090320709 ↗
44. 10.1002/pol.1979.18017010910.1002/pol.1979.180170109 ↗
45. 10.1109/66.33028110.1109/66.330281 ↗
46. 10.1016/j.elstat.2014.05.00610.1016/j.elstat.2014.05.006 ↗
47. Kilic A. · 2017 · 9510.1016/B978-0-08-100573-6.00025-3 ↗
48. 10.1016/j.seppur.2019.11600310.1016/j.seppur.2019.116003 ↗
49. CDC. Steam Sterilization. https://www.cdc.gov/infectioncontrol/guidelines/disinfection/sterilization/steam.html (accessed 2020-04-26).
50. 10.1080/10962247.2013.85865210.1080/10962247.2013.858652 ↗
51. Bionumbers. How Big are Viruses? http://book.bionumbers.org/how-big-are-viruses/ (accessed 2020-04-29).
52. Encyclopaedia Britannica. Coronavirus. https://www.britannica.com/science/coronavirus-virus-group (accessed 2020-04-20).
53. 10.1038/s41586-020-2271-310.1038/s41586-020-2271-3 ↗
54. WHO. Transmission of SARS-CoV-2: Implications for Infection Prevention Precautions (WHO Scientific Brief, July 9, 2020), WHO/2019-nCoV/Sci_Brief/Transmission_modes/2020.3. WHO, 2020.
55. Hinds W. C. · 1999 · 394
56. 10.1002/bit.2161110.1002/bit.21611 ↗
57. 10.1128/AEM.45.3.872-877.198310.1128/AEM.45.3.872-877.1983 ↗
58. 10.1086/52250310.1086/522503 ↗
59. 10.1016/j.jaerosci.2010.06.00110.1016/j.jaerosci.2010.06.001 ↗
60. 10.1016/j.foodres.2013.02.03310.1016/j.foodres.2013.02.033 ↗
61. 10.1111/j.1365-2672.2012.05267.x10.1111/j.1365-2672.2012.05267.x ↗
62. 10.1128/AEM.15.6.1371-1375.196710.1128/AEM.15.6.1371-1375.1967 ↗
63. 10.1016/j.jaerosci.2010.04.00410.1016/j.jaerosci.2010.04.004 ↗
64. 10.1136/jcp.19.1.8310.1136/jcp.19.1.83 ↗
65. 10.3390/ijerph903085510.3390/ijerph9030855 ↗
66. 10.1016/j.foodcont.2013.12.01710.1016/j.foodcont.2013.12.017 ↗
67. 10.1016/j.jhin.2017.08.02510.1016/j.jhin.2017.08.025 ↗
68. 10.1186/2047-2994-2-1910.1186/2047-2994-2-19 ↗
69. CDC. Hand Hygiene Recommendations. https://www.cdc.gov/coronavirus/2019-ncov/hcp/hand-hygiene.html (accessed 2020-05-17).
70. 10.1177/15589250100050040510.1177/155892501000500405 ↗
71. 10.1128/AEM.02674-0910.1128/AEM.02674-09 ↗
72. 10.1038/srep3861010.1038/srep38610 ↗
73. 10.3390/v1207073510.3390/v12070735 ↗
74. 10.1021/acsnano.9b0745210.1021/acsnano.9b07452 ↗
75. 10.1080/02786826.2016.125472010.1080/02786826.2016.1254720 ↗
76. International Organization for Standardization (ISO), ISO 21083-1: Test Method to Measure the Efficiency of Air Filtration Media Against Spherical Nanomaterials–Part 1: Size Range from 20 to 500 nm; Switzerland, 2018.
77. American Society for Testing and Materials (ASTM), ASTM F2100-19e1: Standard Specification for Performance of Materials Used in Medical Face Masks; ASTM International: West Conshohocken, 2019.