How Useful are Conventional I–Vs for Performance Calibration of Single‐ and Two‐Junction Perovskite Solar Cells? A Statistical Analysis of Performance Data on ≈200 Cells from 30 Global Sources
Source abstract
Abstract
As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well‐documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady‐state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady‐state measurement methods take tens of minutes to complete, as opposed to conventional “fast” current–voltage (I–V) measurements usually lasting a few seconds. Fast I–Vs arise from a snapshot, almost always not a steady‐state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I–V and with a steady‐state method? Results compiled from approximately 200 perovskite PV cells, including single junction, and two‐terminal perovskite–perovskite and perovskite–Si tandems, show that fast I–Vs can provide a useful measure of the open‐circuit voltage of the devices, while the short‐circuit current and the overall efficiency can be widely misestimated. The implications of these findings on performance testing protocols are discussed and possible options for fast and accurate testing of perovskite PV are proposed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Perovskite Materials and Applications · Chalcogenide Semiconductor Thin Films · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
PV Cell and Module Performance Group National Renewable Energy Laboratory (NREL) 15313 Denver West Parkway Golden CO 80401 USA
Funding
Solar Energy Technologies Office
References (20)
Show source-provided references
1. NREL Best Research-Cell Efficiency chart https://www.nrel.gov/pv/cell-efficiency.html(accessed: October 2021).
2. 10.1002/pip.344410.1002/pip.3444 ↗
3. 10.1126/science.aat823510.1126/science.aat8235 ↗
4. 10.1021/jz500113x10.1021/jz500113x ↗
5. 10.1039/C4EE02465F10.1039/C4EE02465F ↗
6. 10.1039/C4EE03664F10.1039/C4EE03664F ↗
7. 10.1039/C7TA05609E10.1039/C7TA05609E ↗
8. 10.1002/aenm.20210072810.1002/aenm.202100728 ↗
9. 10.1088/2515-7655/abd67810.1088/2515-7655/abd678 ↗
10. 10.1063/1.496075910.1063/1.4960759 ↗
11. 10.1002/pip.289410.1002/pip.2894 ↗
12. IEC 60904-1: 2020 Photovoltaic devices – Part 1: Measurement of photovoltaic current-voltage characteristics 2020 https://webstore.iec.ch/publication/32004(accessed: October 2021).
13. ASTM E948-16 Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight 2020 https://compass.astm.org/Standards/HISTORICAL/E948-15.htm(accessed: October 2021).
14. ASTM G173-03 Standard Tables for Reference Solar Spectral Irradiances: Direct Normal and Hemispherical on 37° Tilted Surface ASTM Philadelphia PA2006.https://compass.astm.org/EDIT/html_annot.cgi?G173+03(2020)(accessed October 2021).
15. IEC 60904-3 Photovoltaic devices – Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data 2019 https://webstore.iec.ch/publication/61084(accessed: April 2021).
16. Moriarty T. · 2017 · 48310.1109/PVSC.2017.8366424 ↗
17. Song T. · 2019 · 1
18. The linear regression analysis https://www.originlab.com/doc/Origin-Help/LR-Algorithm#Simple_Linear_Regression_Model(accessed: October 2021).
19. Friedman D. J. · 2011
20. Song T. · 2021 · 036710.1109/PVSC43889.2021.9518841 ↗