journal article·2001-03-25

Buckling of aboveground oil storage tanks under internal pressure

Shoichi Yoshida

Steel and Composite Structures· Volume 1· Issue 1
Publisher page

Abstract

Overpressurization can occur due to the ignition of flammable vapors existing inside aboveground oil storage tanks. Such accidents could happen more frequently than other types of accident. In the tank design, when the internal pressure increases, the sidewall-to-roof joint is expected to fail before failure occurs in the sidewall-to-bottom joint. This design concept is the socalled "frangible roof joint" introduced in API Standard 650. The major failure mode is bifurcation buckling in this case. This paper presents the bifurcation buckling pressures in both joints under internal pressure. Elastic and elastic-plastic axisymmetric shell finite element analysis was performed involving large deformation in the prebuckling state. Results show that API Standard 650 does not evaluate the frangible roof joint design conservatively in small diameter tanks.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fluid Dynamics Simulations and Interactions · Spacecraft and Cryogenic Technologies · Structural Integrity and Reliability Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (7)

Show source-provided references
1. International Journal for Numerical Methods in Engineering · 1975 · 9 · 35310.1002/nme.1620090207 ↗
2. Computer & Structures · 1976 · 6 · 22110.1016/0045-7949(76)90034-1 ↗
3. Journal of Pressure Vessel Technology · 1996 · 118 · 32610.1115/1.2842195 ↗
4. International Journal of Mechanical Sciences · 1967 · 9 · 14310.1016/0020-7403(67)90004-5 ↗
5. Transactions of the Japan Society of Mechanical Engineers, Series A · 1988 · 54 · 79410.1299/kikaia.54.794 ↗
6. Journal of Pressure Vessel Technology · 1979 · 101 · 22610.1115/1.3454627 ↗
7. AIAA Journal · 1968 · 6 · 230610.2514/3.4987 ↗