The effects of age and moisture regime on the response of briquetted acoustic gauges
Source abstract
Abstract
In‐situ measurement of concrete strains with acoustic gauges often requires that the gauges are encapsulated or ‘briquetted’ for protection. The effects of age and moisture regime on the response of the briquetted gauge are, however, unknown. Studies extending up to 700 days on these two effects are presented and gauge response is compared to that of the unbriquetted gauge. It is shown that both age and the moisture condition of the briquetted gauge influence its response. By choosing a datum, relevant to their environment and related to some time after the peak of hydration temperature is reached, the response of the briquetted gauge can be made to be close to that of the unbriquetted gauge. Tests show that if this is done the stability and dependability of the briquetted acoustic gauge can be relied upon.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geophysical Methods and Applications · Structural Health Monitoring Techniques · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (6)
Show source-provided references
1. ‘An Interpretation of the Results from Vibrating Wire Strain Gauges in Fresh Concrete’
2. Stevens R. F. · 1966 · 13
3. Lindsay J. A. · 1966 · 67
4. 10.1111/j.1475-1305.1968.tb01340.x10.1111/j.1475-1305.1968.tb01340.x ↗
5. Potter M. M. A. · 1975 · 437
6. Gage Technique Ltd. ‘Technical Specification of T/E/A and T/E/S Gauges’ Bulletin Ref. ASG 1/71.