journal article·2024-05

Simulation Analysis of Mechanical Properties of DC Transmission Lines Under Mountain Fire Condition

G. Q. Li, Z. B. Han, H. Zhu, W. Cui, H. D. Zhao, Y. Zheng, L. T. Fan

Strength of Materials· Volume 56· Issue 3
Publisher page

Abstract

No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.

Source: Not provided · Quality: missing

Research context

OpenAlex topics: Icing and De-icing Technologies · High-Voltage Power Transmission Systems · Thermal Analysis in Power Transmission

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. L. Zhang, J. Li, X. Xu, et al., “High spatial granularity residential heating load forecast based on dendrite net model,” Energy, 269, 126787 (2023).10.1016/j.energy.2023.126787 ↗
2. L. Zhang, T. Hu, L. Zhang, et al., “A novel dynamic opposite learning enhanced Jaya optimization method for high efficiency plate–fin heat exchanger design optimization,” Eng Appl Artif Intel, 119, 105778 (2023).10.1016/j.engappai.2022.105778 ↗
3. Z. Wang, F. You, Y. Zhang, et al., “Damage and mechanism analysis of typical high voltage transmission lines under strong hot flame,” Fire Science and Technology, 34, No. 6, 714–718 (2015).
4. H. Zhu, Z. Han, C. Liu, et al., “Simulation analysis of synthetic electric field of UHV transmission line under mountain fire condition,” Electr Pow Syst Res, 222, 109490 (2023).10.1016/j.epsr.2023.109490 ↗
5. F. Ding, Z. Yu, and H. Wen, “Experimental study on mechanical properties of Q235 steel after high temperature,” J Build Mater, 9, No. 2, 245–249 (2006).
6. J. Yang, X. Ren, X. Wang, et al., “Experimental study on the influence of mountain fire on the safe operation of 10 ~ 35 kV transmission lines,” Sichuan Electric Power Technology, 45, No. 1, 1–5 (2022).
7. N. Yang, B. Yang, C. Yang, et al., “Experimental study on the influence of mountain fire smoke on the insulation of 10 ~ 35 kV transmission lines,” Sichuan Electric Power Technology, 45, No .1, 6–9 + 20 (2022).
8. S. D. Kim and M. M. Morcos, “Mechanical deterioration of ACSR conductors due to forest fires,” IEEE Power Eng Review, 22, No.7, 63–63 (2007).10.1109/MPER.2002.4312435 ↗
9. A. K. Khosrovaneh and N. E. Dowling, “Fatigue loading history reconstruction based on the rainflow technique,” Int J Fatigue, 12, No. 2, 99–106 (1990).10.1016/0142-1123(90)90679-9 ↗
10. C. Amzallag, J. P. Gerey, J. L. Robert, et al., “Standardization of the rain flow counting method for fatigue analysis,” Int J Fatigue 16, No. 4, 287–293 (1994).10.1016/0142-1123(94)90343-3 ↗
11. D. D. Lee, J. M. Shim, Y. D. Kim, et al., “Mechanical and electrical characteristics analysis of the ACSR affected by high temperature,” Rare Metals, 30, No. 1, 311–315 (2011).10.1007/s12598-011-0291-8 ↗
12. D. D. Lee, J. M. Shim, K. S. Park, et al., “Deterioration inference according to mechanical characteristics analysis of ACSR due to an artificial flame and a forest fire,” Rare Metals, 30, No. 1, 305–310 (2011).10.1007/s12598-011-0290-9 ↗
13. J. Q. Liu, Study on the Mechanical and Electrical Properties of Transmission Lines after Wildfires, Taiyuan University of Technology (2017).
14. D. S. Zhang, Design Manual for High Voltage Transmission Lines in Power Engineering, China Electric Power Press, Beijing (2003).
15. J. Liu, Z. Tang, Q. Zheng, et al., “Calculation and analysis of temperature and mechanical parameters of transmission lines when large wildfires take place,” J Taiyuan University of Technology, 48, No. 5, 854–860 (2017).