The limit load calculations for pipelines with axial complex-shaped defects
Source abstract
Abstract
Based on the analytical model for the plastic limit state, a numerical procedure for estimating the remaining strength of a complex-shaped defect has been developed. Comparison of the calculation results obtained by the proposed procedure with the experimental data and the calculation results obtained by other methods showed its efficiency.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Material Properties and Failure Mechanisms · Engineering Diagnostics and Reliability · Engineering Structural Analysis Methods
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (4)
Show source-provided references
1. DNV Recommended Practice-DNV-RP-F101-Corroded Pipelines, Det Norske Veritas, Norway (2004).
2. I. V. Orynyak, “Leak and break models of ductile fracture of pressurized pipe with axial defects,” in: Proc. IPC2006 6th Int. Pipeline Conf. (Sept. 25–29), Calgary, Canada (2006).10.1115/IPC2006-10066 ↗
3. J. F. Kiefner and P. H. Vieth, “PC program speeds new criterion for evaluating corroded pipe,” Oil & Gas J., 88, No. 34, 91–93 (1990).
4. R. D. Souza, A. C. Benjamin, R. D. Vieira, et al., “Part 4: Rupture tests of pipeline segments containing real long corrosion defects,” Exp. Tech., 31, No. 1, 46–51 (2007).10.1111/j.1747-1567.2006.00134.x ↗