journal article·2024-10-01

Reproducible, Accurate, and Sensitive Food Toxin On-Site Detection with Carbon Nanotube Transistor Biosensors

Tingxian Li, Zhongyu Li, Li Wang, Bolun Yu, Mengmeng Xiao, Zhiyong Zhang

ACS Nano· Volume 18· Issue 39
Publisher page

Abstract

Field-effect transistor (FET) biosensors based on nanomaterials are promising in the areas of food safety and early disease diagnosis due to their ultrahigh sensitivity and rapid response. However, most academically developed FET biosensors lack real-world reproducibility and comprehensive methodological validation to meet the standards of regulatory bodies. Here, highly uniform and well-packaged semiconducting carbon nanotube (CNT) FET biosensor chips were developed and assessed for the plug-and-play sensing for the rapid and highly sensitive detection of aflatoxin B1 (AFB1) in real food samples to meet international standards. In order to meet the requirements for reproducibility and stability, a scalable residual-free passivation and packaging process was developed for CNT FET biosensors. Portable detection systems were then constructed for on-site detection. The resulting packaged chips were functionalized with nucleic aptamers to enable highly selective detection of AFB1 in food samples with a detection limit (LOD) of 0.55 fg/mL (standard) for AFB1 and cross-reactivity coefficients to interferences as low as 1.8 × 10 –7 in simulated solutions. Utilizing the portable detection system, on-site real food detection was achieved with a rapid response time less than 60 s, and LOD of 0.25 pg/kg (standard) in complex corn sample matrices. Single-blind tests demonstrated the ability of the chips to detect AFB1-positive food with 100% accuracy, using a set of 30 peanut samples. Validation experiments confirmed that the detection range, stability, and repeatability met international standards. This study showcased the accuracy, reliability, and potential practical applications of CNT FET biosensor chips in areas such as food safety and rapid biomedical testing.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced Chemical Sensor Technologies · Biosensors and Analytical Detection · Electrochemical sensors and biosensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-based Electronics School of Electronics, Peking University, Beijing 100871, China

Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan 411105, Hunan, China

College of Food Science, South China Agricultural University, Guangzhou 510642, China

Oil Crops Research Institute of Chinese Academy of Agricultural Sciences, Wuhan 430062, China

Funding

National Key Research and Development Program of China · National Natural Science Foundation of China · Peking Nanofab Laboratory

References (40)

Show source-provided references
1. 10.1016/j.bios.2017.09.02410.1016/j.bios.2017.09.024 ↗
2. 10.1038/s41467-020-15330-910.1038/s41467-020-15330-9 ↗
3. 10.1002/smll.20220414210.1002/smll.202204142 ↗
4. 10.1111/1541-4337.1202910.1111/1541-4337.12029 ↗
5. 10.1016/j.tifs.2021.01.09310.1016/j.tifs.2021.01.093 ↗
6. 10.3390/antiox1110203110.3390/antiox11102031 ↗
7. 10.1016/j.bios.2017.06.00210.1016/j.bios.2017.06.002 ↗
8. 10.1080/10408398.2022.212191010.1080/10408398.2022.2121910 ↗
9. 10.1016/j.foodchem.2019.12542910.1016/j.foodchem.2019.125429 ↗
10. 10.1016/S0140-6736(98)09261-710.1016/S0140-6736(98)09261-7 ↗
11. 10.1016/j.bios.2023.11572510.1016/j.bios.2023.115725 ↗
12. 10.1016/j.foodchem.2023.13664510.1016/j.foodchem.2023.136645 ↗
13. 10.1016/j.foodchem.2022.13418310.1016/j.foodchem.2022.134183 ↗
14. 10.1016/j.foodres.2023.11277810.1016/j.foodres.2023.112778 ↗
15. 10.1016/j.cej.2023.14749210.1016/j.cej.2023.147492 ↗
16. 10.1021/acssensors.3c0172810.1021/acssensors.3c01728 ↗
17. 10.1149/1945-7111/ac4f2410.1149/1945-7111/ac4f24 ↗
18. 10.1016/j.trac.2023.11722310.1016/j.trac.2023.117223 ↗
19. 10.1016/j.oor.2024.10036310.1016/j.oor.2024.100363 ↗
20. 10.1016/j.colsurfb.2024.11403210.1016/j.colsurfb.2024.114032 ↗
21. 10.1016/j.envres.2023.11719310.1016/j.envres.2023.117193 ↗
22. 10.1039/c9tc07043e10.1039/c9tc07043e ↗
23. 10.1021/ja312282g10.1021/ja312282g ↗
24. 10.1021/acsomega.0c0460710.1021/acsomega.0c04607 ↗
25. 10.1039/C9NJ02993A10.1039/C9NJ02993A ↗
26. 10.1149/2.0781613jes10.1149/2.0781613jes ↗
27. 10.1021/acsnano.7b0086110.1021/acsnano.7b00861 ↗
28. 10.1002/inf2.1242010.1002/inf2.12420 ↗
29. 10.1002/smll.20220819810.1002/smll.202208198 ↗
30. 10.1016/j.jhazmat.2023.13103310.1016/j.jhazmat.2023.131033 ↗
31. 10.1186/1471-2288-5-310.1186/1471-2288-5-3 ↗
32. 10.1109/memb.2007.28912710.1109/memb.2007.289127 ↗
33. 10.1093/jaoac/85.5.118710.1093/jaoac/85.5.1187 ↗
34. Gossler, C.; Schwenzer, F. Method for manufacturing optical waveguide used in medical implant e.g. cochlear implant, involves forming PMMA layer on surfaces of SU8 layer and protective layer that are exposed after photolithographic patterning. DE 102021003426 A1, June 21, 2021.
35. Somnath, V. M.; Swapnil, P. Electrically stable conductive filler-epoxy-based negative photoresist SU8-glycidol polymer nanocomposite element, useful in e.g. sensor, comprises SU8-polymer back encapsulation layer on substrate, and piezoresistive nanocomposite layer. IN331340-B, February 07, 2020.
36. Welch, D.; Christen, J. B. CMOS biosensor system for on-chip cell culture with read-out circuitry and microfluidic packaging. 2012 Aug 28–Sep 01, 2012. In 34th Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society; EMBS: San Diego, CA, 2012, pp 4990–4993.10.1109/EMBC.2012.6347113 ↗
37. 10.1109/JSEN.2022.321645510.1109/JSEN.2022.3216455 ↗
38. 10.1109/tadvp.2005.85842710.1109/tadvp.2005.858427 ↗
39. 10.1126/science.aba598010.1126/science.aba5980 ↗
40. 10.1021/acssensors.8b0000610.1021/acssensors.8b00006 ↗