Tribological properties of ion implanted UHMWPE against Si3N4 under different lubrication conditions
Source abstract
Abstract
Abstract Wear is the primary cause of failure of joint replacement prostheses. In this paper, the ultrahigh molecular weight polyethylene (UHMWPE) was implanted with O + and C + ions at different energies and doses. Its friction and wear behaviors were studied under dry friction, lubrication of distilled water and blood plasma using a pin-on-disk tribometer with a Si 3 N 4 ceramic ball as the counterface. Scanning electron microscopy was used to examine the surfaces of un-implanted and implanted UHMWPE before and after wear. The experimental results show that the wear resistance of the implanted UHMWPE is higher than that of the un-implanted UHMWPE under dry friction, lubrication of distilled water and blood plasma. The wear resistance of the O + -implanted UHMWPE is better than that of the C + -implanted, especially for 450 keV energy and 5×10 15 /cm 2 dose O + -implanted sample, of which the wear rate is the lowest. The wear rates of the implanted and un-implanted UHMWPE are higher under dry friction than under the blood plasma lubrication. The adhesion, ploughing and plastic deformation are the wearing mechanisms for the un-implanted UHMWPE, while the fatigue and abrasive wear for the implanted UHMWPE.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Tribology and Wear Analysis · Advanced materials and composites
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. McGee · Proc. Inst. Mech. Eng. Part H · 1997 · 211 · 6510.1243/0954411971534692 ↗
2. Fan · Chin. J. Orthop. · 1998 · 18 · 518
3. D.S. Xiong, S.R. Ge, Research status of bio-tribological behaviors of UHMWPE, J. CUMT, 28 (Tribological Monograph) (1999) 49–52 (in Chinese)
4. Weightman · Biomaterials · 1986 · 7 · 2010.1016/0142-9612(86)90083-9 ↗
5. Jalali-Vahid · J. Biomech. · 2001 · 34 · 26110.1016/S0021-9290(00)00181-0 ↗
6. Jin · Proc. Inst. Mech. Eng. · 1997 · 211 · 24710.1243/0954411971534359 ↗
7. Dowson · Wear · 1995 · 190 · 17110.1016/0043-1648(96)80015-9 ↗
8. Xiong · Wear · 2001 · 250 · 24210.1016/S0043-1648(01)00647-0 ↗
9. Dong · Wear · 1999 · 225–229 · 14610.1016/S0043-1648(98)00356-1 ↗
10. Ohta · Wear · 2001 · 250 · 14510.1016/S0043-1648(01)00606-8 ↗
11. Chang · Wear · 2000 · 241 · 10910.1016/S0043-1648(00)00393-8 ↗
12. Mckellop · J. Clin. Orthop. Relat. Res. · 1999 · 369 · 7310.1097/00003086-199912000-00008 ↗
13. A. Wang, D.C. Sun, C. Stark, et al., Effects of sterilization methods on the wear of ultra-high molecular weight polyethylene acetabular cups, Proceeding of Fifth World Biomaterials Congress, University of Toronio Press, Toronto, Canada, 1996, pp. II-198
14. Rao · J. Mater. Res. · 1995 · 10 · 19010.1557/JMR.1995.0190 ↗
15. Lee · Surf. Coat. Technol. · 1992 · 51 · 26710.1016/0257-8972(92)90250-E ↗
16. Xiong · High Technol. Lett. · 2002 · 12 · 60
17. Han · Surf. Coat. Technol. · 1997 · 93 · 26110.1016/S0257-8972(97)00057-1 ↗
18. Xiong · Chin. J. Biomed. Eng. · 2001 · 20 · 380
19. Shi · Wear · 2001 · 250 · 54410.1016/S0043-1648(01)00636-6 ↗
20. Walker · J. Biomech. · 1997 · 30 · 8310.1016/S0021-9290(96)00118-2 ↗
21. Fisher · Proc. Inst. Mech. Eng. (Part H) · 1995 · 209 · 26310.1243/PIME_PROC_1995_209_353_02 ↗
22. Saikko · Wear · 1993 · 166 · 16910.1016/0043-1648(93)90259-O ↗