Application of thermal oxidation to the development of PM 2000 as potential biomaterial for medical devices
Source abstract
Abstract
PM 2000 is a FeCrAl alloy suitable to be coated with a dense α-alumina layer by thermal oxidation, combining the inherent mechanical properties of the substrate with a good biocompatibility in vitro. The associated elevated residual stresses in the coating account for the capability to deform without cracking and also enhances the fatigue limit. Such residual stresses could also be beneficial for the wear behaviour. However, oxide nodules developed at the outer part of the scale provide the material with a high roughness that precludes their use for articulating surfaces. The aim of this investigation is to find out the optimal conditions for the defined thermal oxidation treatment in order to form a dense, adherent but smooth alumina scale. The effect of a short vacuum heating stage prior to oxidation on the kinetics, surface scale composition and roughness has been investigated. The development of the surface roughness follows an approximate parabolic law, which is in accordance with the oxide growth. Regarding the roughness, the maximum permissible value of 50 nm for an articulating surface is reached before 1 h exposure, irrespective of the oxidation process. A final manual polishing, however, was found to provide a smaller roughness value. To check the influence of the scale formation on the wear rate of UHMWPE, a set of femoral heads of standards dimensions, with and without alumina layer, were prepared. For comparative purposes, femoral heads of CoCr and 316 LVM stainless steel, currently used, were also tested for 10 million cycles in a four-station simplified joint wear simulator with bi-directional motion. Above 3.7 million cycles, preoxidised and polished PM 2000, with a roughness of about 40 nm, clearly causes the smaller polyethylene wear rate. Results confirm that the higher material roughness the higher wear rate. © 2005 Elsevier B.V. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Konttinen · Curr. Orthop. · 1997 · 11 · 4010.1016/S0268-0890(97)90050-5 ↗
2. Ingham · Biomaterials · 2005 · 26 · 127110.1016/j.biomaterials.2004.04.035 ↗
3. Tribology of aluminium ceramics
4. Schmalzried · J. Bone Jt. Surg., Br. · 1999 · 81 A · 11510.2106/00004623-199901000-00016 ↗
5. Hayashi · J. Biomed. Mater. Res. · 1989 · 23 · 124710.1002/jbm.820231103 ↗
6. Zywitzki · Surf. Coat. Technol. · 1996 · 82 · 16910.1016/0257-8972(95)00270-7 ↗
7. Fraissinet · J. Mater. Sci., Mater. Med. · 1994 · 5 · 49110.1007/BF00058989 ↗
8. Bull · Surf. Coat. Technol. · 1996 · 82 · 21810.1016/0257-8972(95)02641-X ↗
9. Christensen · Acta Mater. · 1997 · 45 · 176110.1016/S1359-6454(96)00258-3 ↗
10. Davidson · Biomed. Mater. Eng. · 1994 · 4 · 231
11. Oonishi · Ann. N.Y. Acad. Sci. · 1988 · 523 · 3810.1111/j.1749-6632.1988.tb38499.x ↗
12. Escudero · Biomaterials · 1994 · 15 · 117510.1016/0142-9612(94)90239-9 ↗
13. García-Alonso · J. Mater. Sci., Mater. Med. · 2001 · 12 · 58910.1023/A:1011281425321 ↗
14. González-Carrasco · Mater. Manuf. Process. · 1998 · 13 · 43110.1080/10426919808935260 ↗
15. Growth Programme “Development of alumina forming ODS ferritic superalloys as new biomaterials for surgical implants (ALUSI)” GRD1-1999-10659, Final Report.
16. Ciapetti · Biomaterials · 2005 · 26/8 · 84910.1016/j.biomaterials.2004.03.032 ↗
17. Enhanced osteoblast functions on new Fe-based Ni-free alloys containing nanoparticles
18. González Carrasco · Biomaterials · 2005 · 26 · 386110.1016/j.biomaterials.2004.09.058 ↗
19. Flores · J. Mater. Sci., Mater. Med. · 2004 · 15 · 110.1023/B:JMSM.0000026100.73945.85 ↗
20. Prasanna · Oxid. Met. · 1996 · 46(5/6) · 46510.1007/BF01048641 ↗
21. Doychack · Oxid. Met. · 1989 · 32 · 43110.1007/BF00666466 ↗
22. González-Carrasco · Oxid. Met. · 2001 · 55 · 20910.1023/A:1010351909187 ↗
23. Pérez · Surf. Coat. Technol. · 2001 · 139 · 20710.1016/S0257-8972(00)01169-5 ↗
24. González-Carrasco · Mater. Corros. · 2001 · 52 · 86010.1002/1521-4176(200111)52:11<860::AID-MACO860>3.0.CO;2-9 ↗
25. Hazan · Biomaterials · 1993 · 14 · 57010.1016/0142-9612(93)90172-X ↗
26. V.A.C. Haanappel, P. Pérez, M.F. Stroosnijder, SMT-14 (Surface Modification Technology-14), 11–13 September, 2000, Paris.
27. Birks · 1983
28. Quadakkers · Mater. Corros. · 1990 · 41 · 65910.1002/maco.19900411204 ↗
29. Guttmann · 2000 · 43
30. Guttmann · 1999 · 17
31. Czyrska-Filemonowicz · 1993 · 288
32. Growth of α-alumina scales on Fe–Cr–Al alloys
33. Göbel · 1997 · 12
34. Barin · 1989
35. Hilpert · J. Electrochem. Soc. · 1996 · 143 · 364210.1149/1.1837264 ↗
36. Comparison of MTS and Stanmore knee wear simulators