Temperature-engineered Ti-based thin-film metallic glass coatings with superior electrochemical and biological stability for bioimplants
Source abstract
Abstract
The durability of titanium-based biomedical implants is affected by the aggressive physiological environment, leading to eventual wear, corrosion, and ultimately implant failure. To overcome these challenges, we report a biocompatible Ti49Cu31Ta10Nb10 thin-film metallic glass (TFMG) system, as determined by XPS, fabricated by magnetron sputtering onto medical-grade titanium (Ti) substrates. The TiCuTaNb TFMG systems are being widely studied as next-generation thin-film coatings to prolong the life of implants. The key characteristics of the TFMGs are seriously dependent on factors such as the surface properties and deposition temperature. In this work, the TiCuTaNb TFMGs were fabricated by magnetron sputtering at ambient temperature, 250 °C, and 500 °C to elucidate the influence of deposition temperature and to investigate their structure, thermal stability, and corrosion resistance for bioimplant applications. Structural analyses revealed that amorphous coatings remain stable up to 250 °C, while higher temperatures induce Ti₂Cu nanocrystallisation. Increasing the deposition temperature led to higher hardness and elastic modulus, indicating the formation of a nanocrystalline phase. Amorphous TFMGs (deposited at ≤250 °C) act as an impenetrable barrier, providing exceptional electrochemical resistance in simulated body fluids (SBF) compared to bare titanium. In vitro bioactivity assessments demonstrated temperature-dependent calcium phosphate mineralisation, with the nanocrystalline coating exhibiting the highest Ca/P ratio, approaching that of hydroxyapatite. The TFMGs are hemocompatible, with reduced platelet adhesion and delayed blood clot formation. The cytocompatible coatings promote the biological performance of MC3T3-E1 cells, including adhesion and proliferation. This study establishes a relationship between the structural properties and the biological performance of TiCuTaNb TFMGs, a promising coating for orthopedic implants
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · Electrodeposition and Electroless Coatings · Nanoporous metals and alloys
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (82)
Show source-provided references
1. Biocompatibility of titanium from the viewpoint of its surface10.1080/14686996.2022.2106156 ↗
2. Surface modifications of biomaterials in different applied fields10.1039/D3RA02248J ↗
3. A comprehensive review on biocompatible thin films for biomedical application10.1016/j.ceramint.2021.10.243 ↗
4. Surface engineering of pure magnesium in medical implant applications10.1016/j.heliyon.2024.e31703 ↗
5. Thin film metallic glasses: unique properties and potential applications10.1016/j.tsf.2012.03.092 ↗
6. New-generation biocompatible Ti-based metallic glass ribbons for flexible implants10.1016/j.matdes.2022.111139 ↗
7. Bio-compatible zirconium-based thin film metallic glasses with nitrogen reinforced by micro-alloying technique10.1016/j.matchemphys.2021.124965 ↗
8. Titanium-based alloys and composites for orthopedic implants applications: a comprehensive review10.1016/j.matdes.2024.112850 ↗
9. Multifunctional coatings on implant materials—a systematic review of the current scenario
10. Biological performance of metal metalloid (TiCuZrPd:B) TFMG fabricated by pulsed laser deposition
11. Cytocompatibility assessment of Ti-Nb-Zr-Si thin film metallic glasses with enhanced osteoblast differentiation for biomedical applications10.1016/j.colsurfb.2018.09.041 ↗
12. Recent progress in Ti-based metallic glasses for application as biomaterials10.2320/matertrans.MF201315 ↗
13. Fabrication of Zr-Ti-Si glassy metallic overlay on 3D printed Ti-6Al4V implant prototypes for enhanced biocompatibility10.1016/j.jallcom.2023.170933 ↗
14. Thin film metallic glasses for bioimplants and surgical tools: A review10.1016/j.jallcom.2021.159939 ↗
15. Antibacterial effect of copper-bearing titanium alloy (Ti-Cu) against Streptococcus mutans and Porphyromonas gingivalis
16. Antibacterial Ti–Cu implants: a critical review on mechanisms of action
17. Corrosion resistance and biocompatibility of Ti-Ta alloys for biomedical applications10.1016/j.msea.2005.03.032 ↗
18. Additively manufactured Ti–Ta–Cu alloys for the next-generation load-bearing implants
19. Perspectives on metallic biomaterials for implants: the emerging role of Ti-Nb alloys and additive manufacturing
20. Effect of process parameters on the properties of β-Ti-Nb-based alloys fabricated by selective laser melting: A review10.1016/j.matpr.2023.03.461 ↗
21. Biomineralization of osteoblasts on DLC coated surfaces for bone implants
22. Hemocompatibility of titanium oxide films10.1016/S0142-9612(03)00046-2 ↗
23. Biocompatibility and corrosion evaluation of niobium oxide coated AZ31B alloy for biodegradable implants10.1016/j.colsurfb.2022.112342 ↗
24. Tribological, electrochemical and in vitro biocompatibility properties of SiC reinforced composite coatings10.1016/j.matdes.2016.01.143 ↗
25. In situ synthesized TiB-TiN reinforced Ti6Al4V alloy composite coatings: Microstructure, tribological and in-vitro biocompatibility10.1016/j.jmbbm.2013.09.006 ↗
26. Effect of fluorine substitution on sintering behaviour, mechanical and bioactivity of hydroxyapatite10.1016/j.jmbbm.2019.03.032 ↗
27. Structural evolution in Ti-Cu-Ni metallic glasses during heating10.1063/1.4905287 ↗
28. Crystalline–amorphous nanostructures: microstructure, property and modelling10.3390/ma16072874 ↗
29. Studies on the morphological and mechanical properties of TiZrHfNiCuCo metallic coatings deposited by DC magnetron sputtering10.3390/coatings14091179 ↗
30. Modification of structure and property in Zr-based thin film metallic glass via processing temperature control10.1016/j.tsf.2013.05.179 ↗
31. Effects of annealing on mechanical behavior of Zr–Ti–Ni thin fi lm metallic glasses10.1016/j.msea.2014.03.144 ↗
32. ZrCuAg thin-film metallic glasses: toward biostatic durable advanced surfaces10.1021/acsami.1c01127 ↗
33. Effect of annealing on mechanical properties and thermal stability of ZrCu/O nanocomposite amorphous films synthetized by pulsed laser deposition10.1016/j.matdes.2022.110972 ↗
34. Electrochemical Surface Nanostructuring of Ti47Cu38Fe2.5Zr7.5Sn2Si1Ag2 Metallic Glass for Improved Pitting Corrosion Resistance10.1002/adem.202302206 ↗
35. Windler · 2001
36. Peak-fitting of Cu 2p photoemission spectra in Cu0, Cu1+, and Cu2+ oxides: A method for discriminating Cu0 from Cu1+10.1016/j.apsusc.2023.156960 ↗
37. Total aerobic destruction of azo contaminants with nanoscale zero-valent copper at neutral pH: Promotion effect of in-situ generated carbon center radicals10.1016/j.watres.2014.08.011 ↗
38. Preparation and electrical properties of a copper-conductive polymer hybrid nanostructure10.1039/C6RA20325F ↗
39. XPS investigation of monatomic and cluster argon ion sputtering of tantalum pentoxide10.1016/j.apsusc.2017.02.006 ↗
40. Sputter-coated N-enriched mixed metal oxides (Ta2O5-Nb2O5-N) composite: a resilient solar driven photocatalyst for water purification10.1016/j.jhazmat.2023.131283 ↗
41. Biocompatibility screening of Mo–Si–Ta glassy alloy films sputtered on additive manufactured Ti–6Al–4V implant prototypes and PCL scaffolds10.1016/j.matchemphys.2023.128664 ↗
42. Biological performance of metal metalloid (TiCuZrPd:B) TFMG fabricated by pulsed laser deposition10.1016/j.colsurfb.2021.111684 ↗
43. Differential scanning calorimetry: Fundamental overview10.1007/s12045-009-0076-7 ↗
44. Improved plasticity and corrosion behavior in Ti-Zr-Cu-Pd metallic glass with minor additions of Nb: An alloy composition intended for biomedical applications10.1016/j.msea.2012.08.058 ↗
45. The influence of heat treatment on the structure and thermal properties of metallic glasses10.1007/s10973-016-5633-1 ↗
46. Comparative EIS study of titanium-based materials in high corrosive environments10.1504/IJSURFSE.2021.116333 ↗
47. Electrochemical Impedance Spectroscopy (EIS) principles and biosensing applications
48. Combinatorial development of metallic glasses with superior corrosion resistance via electron work function10.1016/j.jmst.2025.04.029 ↗
49. Improving surface characteristic and corrosion inhibition of coating on Mg alloy by trace stannous (II) chloride10.1016/j.corsci.2017.04.018 ↗
50. Improved corrosion behaviour of electron beam melted Ti-6Al–4V alloy in phosphate buffered saline10.1016/j.corsci.2017.05.003 ↗
51. Preparation of highly dense Ti-based coatings with enhanced corrosion protection performance via cold spray10.1016/j.surfcoat.2023.130002 ↗
52. Biomedical evaluation of Mo dispersed TaNb oxide thin films by combinatorial sputtering10.1007/s10853-025-11137-5 ↗
53. Characterization of different materials for corrosion resistance under simulated body fluid conditions10.1016/S1044-5803(02)00320-0 ↗
54. Superior corrosion-resistant Zr-Ti-Ag thin film metallic glasses as potential biomaterials10.1016/j.apsusc.2024.160712 ↗
55. Preparation of calcium deficient hydroxyapatite on the montmorillonite substrate: Structure and morphology10.1016/j.matpr.2020.02.927 ↗
56. Corrosion behavior of anodized Ti-Ta binary surface alloys in various physiological fluids for implant applications10.1016/j.corsci.2023.111233 ↗
57. Structural evolution of metallic glasses during annealing through in situ synchrotron X-ray diffraction10.1016/j.jnoncrysol.2008.05.061 ↗
58. Fabrication of Ni-free Ti-based bulk-metallic glassy alloy having potential for application as biomaterial, and investigation of its mechanical properties, corrosion, and crystallization behavior10.1557/jmr.2007.0154 ↗
59. Crystallization of Ti 33Cu 67 metallic glass under high-current density electrical pulses10.1186/1556-276X-6-512 ↗
60. Crystallization of Cu50Ti50 and Cu66Ti34 metallic glasses10.1080/01418618708209847 ↗
61. Influence of surface roughness and annealing on the structural, optical, electrical, and magnetic properties of Co40Fe40Dy20 thin films deposited on glass substrate10.1016/j.ceramint.2024.05.209 ↗
62. Effect of substrate temperature on thermochromic vanadium dioxide thin films sputtered from vanadium target10.1063/1.5035540 ↗
63. Theory of sputtering. I. Sputtering yield of amorphous and polycrystalline targets10.1103/PhysRev.184.383 ↗
64. The effect of deposition conditions on the properties of Zr-carbide, Zr-nitride and Zr-carbonitride coatings – a review10.1039/D0MA00232A ↗
65. Atomistic mechanism for nanocrystallization of metallic glasses10.1016/j.actamat.2008.02.019 ↗
66. Preparation of Zr-Al-Mo-Cu Single Targets with Glass Forming Ability and Deposition of Thin Film Metallic Glass10.3390/coatings10040398 ↗
67. The microstructure and mechanical properties of nitrogen and boron contained ZrCuAlNi thin film metallic glass composites10.1016/j.surfcoat.2013.09.015 ↗
68. Effects of substrate temperature on structure, thermal stability and mechanical property of a Zr-based metallic glass thin film10.1016/j.tsf.2015.10.049 ↗
69. Effects of B addition on glass formation, mechanical properties and corrosion resistance of the Zr66.7−xNi33.3Bx (x = 0, 1, 3, and 5 at.%) metallic glasses10.1007/s11837-015-1737-5 ↗
70. Distinctive Features and Fabrication Routes of Metallic-Glass Systems Designed for Different Engineering Applications: A Review10.3390/coatings13101689 ↗
71. Balakrishnan · 2008 · 22 · 58
72. Amorphous alloys as a promising class of functional materials. Pt. 1: manufacturing methods, structure, physical and mechanical properties10.15407/ufm.26.03.598 ↗
73. Temperature dependency of impedance, dielectric, and conductivity properties for Si-p/beta-FeSi2-n heterostructures created through facing target sputtering10.1016/j.mssp.2024.108499 ↗
74. Effects of deposition temperature on microstructure and electrical resistivity of intrinsic CVD-SiC10.1016/j.ceramint.2025.03.174 ↗
75. Relationship between amorphous structure and corrosion behaviour in a Zr–Ni metallic glass10.1016/j.corsci.2012.02.017 ↗
76. Effect of grain size on corrosion: a review10.5006/1.3462912 ↗
77. Effects of nanoscale chemical heterogeneity on the wear, corrosion, and tribocorrosion resistance of Zr-based thin film metallic glasses10.1016/j.surfcoat.2020.126324 ↗
78. Fabrication of sputter coated Cu impregnated TaO–NbO composite: A synchronized scavenging photocatalyst for water purification
79. Are there sufficient standards for the in vitro hemocompatibility testing of biomaterials?10.1186/1559-4106-8-33 ↗
80. Blood-contacting biomaterials: in vitro evaluation of the hemocompatibility10.3389/fbioe.2018.00099 ↗
81. Microstructure and antimicrobial properties of Zr-Cu-Ti thin-film metallic glass deposited using high-power impulse magnetron sputtering10.3390/ma15072461 ↗
82. Electrochemical corrosion behavior and in vitro biocompatibility of Ti-Nb-Sn alloy for dental applications10.1016/j.corsci.2023.111531 ↗