Abstract

It has been shown that the surface quality of cardiovascular stents has a significant influence on the biocompatibility. In particular, a smooth surface is required. The major objective of the present study is to explore the optimal methods for polishing NiTi stents. Electrochemical polishing was mainly explored, in which several parameters were investigated including applied voltage, polishing time, as well as acid pickling prior to polishing. As a comparison, chemical polishing was also conducted. Both mechanical and electrochemical polishing of NiTi sheet material were employed in order to study the influence of electrochemical polishing on the surface composition of the NiTi stent. Pickling was necessary prior to electrochemical polishing for removing the oxide films covering the stent surface. An optimal condition for polishing was found and could provide a significant improvement of the surface quality of the NiTi stents.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Electrodeposition and Electroless Coatings · Advanced Machining and Optimization Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

The Department of Metallurgy and Materials EngineeringKatholieke Universiteit Leuven, Kasteelpark Arenberg 44, B–3001, Heverlee, Belgium (jan.vanhumbeeck@mtm.kuleuven.ac.be)

The Department of CardiologyUniversity Hospital Gasthuisberg, Katholieke Universiteit Leuven, Herestraat 49, B–3000, Leuven, Belgium

References (22)

Show source-provided references
1. LIPSCOMB I. P., and NOKES L. D. M. ‘The application of shape memory alloys in medicine’, 87; 1996, London, MEP.
2. SIGWART U. ‘Endoluminal stenting’, 205–209; 1996, London, W. B. Saunders Co.
3. LIPSCOMB J. P., and NOKES L. D. M. ‘The application of shape memory alloys in medicine’, 71; 1996, London, MEP.
4. WILLIAMS D. F. ‘Endoluminal stenting’, 45–50; 1996, London, W. B. Saunders Co.
5. SCHARNWEBER D. ‘Metals as biomaterials’, 104–112; 1998, London, Wiley.
6. WANG K. · 162 · 89
7. STEINEMANN S. G. · Injury · 1996 · 27 · 5C16
8. 10.1016/S0735-1097(98)00289-710.1016/S0735-1097(98)00289-7 ↗
9. STAAB M. E., HOLMES D. R.Jr, and SCHWARTZ R. S. ‘Endoluminal stenting’, 34–44; 1996, London, W. B. Saunders Co.
10. LUNN A. C. ‘Endoluminal stenting’, 80–83; 1996, London, W. B. Saunders Co.
11. BAKER J. E., HORN J. B., NIKOLAYCHIK V., and KIPSHIDZE N. N. ‘Endoluminal stenting’, 84–89; 1996, London, W. B. Saunders Co.
12. MCP: ‘The MCP system of electropolishing: an overview’, Internet www.electropolish.com.
13. SHIGOLEV P. V. ‘Electrolytic and chemical polishing of metals’, 2nd edn, 9–10, 23; 1974, Tel-Aviv, Freund Publishing.
14. HUMBEECK J. VAN, STALMANS R., and BESSELINK P. A. ‘Metals as biomaterials’, 73–98; 1998, London, Wiley.
15. 10.1016/S0142-9612(97)00210-X10.1016/S0142-9612(97)00210-X ↗
16. CHANG R. T., CAMPBELL T. H., and BLOEM m. O.: Proc. 2nd Int. Conf. on ‘Shape memory and superelastic technologies’, Pacific Grove, CA, USA, 1997, SMST, 579–584.
17. RYHÄNEN J., NIEMI E., SERLO W., NIEMELA E., SANDVIK P., PERNU H., and SALO J. T.: Proc. 2nd Int. Conf. on ‘Shape memory and superelastic technologies’, Pacific Grove, CA, USA, 1997, SMST, 407–409.
18. 10.1111/j.1540-8183.2000.tb00286.x10.1111/j.1540-8183.2000.tb00286.x ↗
19. 10.1111/j.1540-8183.1990.tb00974.x10.1111/j.1540-8183.1990.tb00974.x ↗
20. BAUCCIO M. L. ‘Materials properties handbook: titanium alloys’, (ed. Boyer R. et al), 1145–1158; 1994, Materials Park, OH, ASM International.
21. 9
22. JUMER J. F. ‘Electropolishing’, Electro-Glo Co., Chicago, 494-504.