Process limitations of magnetically enhanced reactive ion etch equipment
Source abstract
Abstract
In magnetically enhanced reactive ion etching (MERIE), it is conventionally understood that the etch rate increases with increasing magnetic field strength (MFS) owing to the increase in plasma density. However, it is uncertain that this can be valid under various plasma conditions. This concern was investigated by applying a statistical experimental design to an etching of aluminium thin films in a chlorine (Cl2) plasma. It was noticeable that five experimental cases were contradictory to the reported MFS effect. The major contributor was estimated to be the dominant effect of ion bombardment. The sensitivity analysis of three significant cases revealed a little interaction between MFS and Cl2 flow. Demonstrated high sensitivity of each contradictory case reveals that the process limitations of MERIE can be circumvented by controlling the process parameters.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Semiconductor materials and devices · Plasma Diagnostics and Applications · Copper Interconnects and Reliability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Electronic Engineering, Sejong University, Seoul 143 747, Korea
Department of Electronic Engineering, Kwangwoon University, Seoul 139 701, Korea
Department of Electronic Engineering, Myongji University, Yongin 449 728, Korea
References (9)
Show source-provided references
1. Cheng D. · US Patent No. 5,215,619
2. 10.1143/JJAP.34.214710.1143/JJAP.34.2147 ↗
3. 10.1116/1.58489710.1116/1.584897 ↗
4. 10.1179/026708404X109910.1179/026708404X1099 ↗
5. Kim B. · J. Korean Phys. Soc · 2005 · 46 · 460
6. Mongomery D. C. · 1991
7. 10.1143/JJAP.34.214710.1143/JJAP.34.2147 ↗
8. Ye Y. · Electrochem. Soc. Proc · 1996 · 12 · 222
9. Varhue W. · Electrochem. Soc. Proc · 1991 · 11 · 244