The aim of the work was to verify the influence of positive pulses in the high-power impulse magnetron sputtering (HiPIMS) method on the formation of the adhesion interface between the Ti coating and the polyetheretherketone (PEEK). Two variants of PEEK materials were tested, a non-conductive one in the basic state and a conductive one filled with carbon nanotubes. The depth profile of the chemical composition was tested using the XPS method with Ar + ion bombardment. A positive pulse applied to the non-conductive PEEK enables the implantation of Ti ions, but the depth of implantation is lower than for a combination of a positive pulse with a DC negative bias applied to the conductive PEEK. However, a positive pulse has a clear effect on the formation of a chemically pure interface without the formation of an atomic inter-mixed layer.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Semiconductor materials and devices · Diamond and Carbon-based Materials Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Faculty of Mechanical Engineering, Czech Technical University in Prague

Faculty of Mathematics and Physics, Charles University

References (23)

Show source-provided references
1. 10.1016/j.apsusc.2018.12.08010.1016/j.apsusc.2018.12.080 ↗
2. 10.1016/j.surfcoat.2021.12715210.1016/j.surfcoat.2021.127152 ↗
3. 10.1016/j.apsusc.2019.07.23910.1016/j.apsusc.2019.07.239 ↗
4. 10.1016/S0257-8972(97)00403-910.1016/S0257-8972(97)00403-9 ↗
5. 10.1088/0963-0252/11/2/30710.1088/0963-0252/11/2/307 ↗
6. 10.1088/0022-3727/42/9/09300110.1088/0022-3727/42/9/093001 ↗
7. 10.1088/1361-6595/ab8fbb10.1088/1361-6595/ab8fbb ↗
8. 10.1080/09506608.2021.195480510.1080/09506608.2021.1954805 ↗
9. 10.1186/1556-276X-6-41910.1186/1556-276X-6-419 ↗
10. 10.1016/j.apsusc.2012.12.07110.1016/j.apsusc.2012.12.071 ↗
11. 10.1016/j.matdes.2022.11095810.1016/j.matdes.2022.110958 ↗
12. Mittal KL Netravali AN (eds). Polymer surface modification to enhance adhesion. Hoboken New Jersey USA: Wiley 2024. Epub ahead of print March 13 2024. DOI: 10.1002/9781394231034.10.1002/9781394231034 ↗
13. 10.3390/coatings1012116510.3390/coatings10121165 ↗
14. 10.1088/1361-6595/abc6f610.1088/1361-6595/abc6f6 ↗
15. 10.1016/j.surfcoat.2015.12.07110.1016/j.surfcoat.2015.12.071 ↗
16. 10.3390/coatings1003027410.3390/coatings10030274 ↗
17. Current MI. Perspectives on low-energy ion (and neutral) implantation. In: 2017 17th international workshop on junction technology (IWJT). IEEE, pp.7–12.
18. 10.1063/1.182939010.1063/1.1829390 ↗
19. 10.1016/j.nimb.2012.11.07810.1016/j.nimb.2012.11.078 ↗
20. 10.1016/j.nimb.2004.01.19510.1016/j.nimb.2004.01.195 ↗
21. Popok V. Ion implantation of polymers: formation of nanoparticulate materials. Mater Sci 2012; 30: 1–26.
22. 10.1016/j.nimb.2023.16509710.1016/j.nimb.2023.165097 ↗
23. 10.1016/j.surfcoat.2015.10.07010.1016/j.surfcoat.2015.10.070 ↗