Characterisation of surface morphology of high voltage DC relay contacts under arc erosion
Source abstract
Abstract
Abstract High voltage DC relays are a crucial component in new energy vehicles. Due to the high failure rate caused by contact sticking (fusion welding), existing technologies can only analyze contact morphology after failure. There is an urgent need to determine the quantitative characterization value of contact surface morphology and the correlation between morphology, failure mechanisms, and working conditions. In this study, an Olympus DSX1000 microscope is used to extract surface topography data, and a quantitative topography characterization method based on a machine vision system is proposed to quantitatively analyze contact surface changes after arc erosion. Grey correlation analysis was applied to explore the relationship between electrical parameters such as voltage, current, and capacitance, and the contact morphology features. The results show that current and capacitance have the greatest influence on contact surface features after arc erosion, while voltage has a relatively smaller influence. This conclusion is consistent with the experimentally observed arc erosion features. Finally, an arc ion sputtering deposition model was developed to analyze the material transfer mode and its influence on the contact failure mechanism. The results provide a scientific basis for the analysis and design improvement of high voltage DC relays.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrical Contact Performance and Analysis · Vacuum and Plasma Arcs · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Development of a compact relay for high voltage switching of up to 1000V and 40A
2. A novel DC distance relay for MVDC microgrids10.1109/TSG.2021.3135791 ↗
3. High voltage security system design and testing of electric car10.11591/telkomnika.v12i5.4899 ↗
4. Studies of a high voltage management system in electric vehicles10.4028/www.scientific.net/AMM.80-81.825 ↗
5. 11 - High voltage battery management systems (BMS) for electric vehicles10.1016/B978-1-78242-377-5.00011-X ↗
6. Arc erosion behavior of Ag/Ti3AlC2 electrical contact materials10.1016/j.jallcom.2018.01.015 ↗
7. Study on properties of AgSnO2 contact materials doped with rare earth Y10.1088/2053-1591/aad24b ↗
8. Arc erosion behavior and mechanism of Ag/Ti3SiC2 cathodes in different atmospheres10.1016/j.ceramint.2020.09.074 ↗
9. Triboelectric behaviors of materials under high speeds and large currents10.1007/s40544-013-0024-0 ↗
10. Feature-based characterisation of surface topography and its application10.1016/j.cirp.2021.05.001 ↗
11. A review of micro-contact physics, materials, and failure mechanisms in direct-contact RF MEMS switches10.1088/0960-1317/26/10/104004 ↗
12. Effect of electrical load on contact welding failure of silver tin oxide material used in DC electromechanical relays10.1109/ACCESS.2019.2940966 ↗
13. Analysis of surface roughness morphology with TRIZ methodology in automotive electrical contacts: Design against third body fretting-corrosion10.1016/j.triboint.2019.106019 ↗
14. Investigations on mass change and surface morphology of contacts in electromagnetic contactor10.1109/HOLM.2003.1246483 ↗
15. Wear mechanism and mass loss characteristic of arcing contacts in SF 6 circuit breaker in making process10.1109/TCPMT.2018.2833123 ↗
16. Research on contact difference plane layering and corrosion zoning of sealed relay contacts10.1002/tee.22980 ↗
17. Experimental investigation of cold adhesion failure physical mechanism of gold plated contact within the Micro-Electromechanical-Relay10.1016/j.engfailanal.2020.105151 ↗
18. A novel multiscale adaptive binning phase congruency feature for SAR and optical image registration10.1109/TGRS.2022.3206804 ↗
19. Effect of electrical parameters on morphology, chemical composition, and photoactivity of the nano-porous titania layers synthesized by pulse-microarc oxidation10.1016/j.electacta.2009.12.043 ↗
20. Study on the delamination wear and its influence on the conductivity of the carbon contact strip in pantograph-catenary system under high-speed current-carrying condition10.1016/j.wear.2021.203823 ↗
21. Influence of electric current on the wear topography of electrical contact surfaces10.1115/1.4053585 ↗
22. Research on the rolling and sliding behavior of making contact and associated welding mechanism for low-current switching devices10.1109/TCPMT.2018.2827035 ↗
23. Visualization and mechanisms of splashing erosion of electrodes in a DC air arc10.1088/1361-6463/aa92fb ↗
24. An adaptive Gaussian filter for noise reduction and edge detection10.1109/NSSMIC.1993.373563 ↗
25. An adaptive gauss filtering method10.1109/PACIFICVIS.2008.4475468 ↗
26. Face mask recogniser using image processing and computer vision approach10.1016/j.gltp.2022.04.016 ↗
27. Industrial survey of ISO surface texture parameters10.1016/j.cirpj.2017.06.001 ↗
28. Research on optimal decision-making of cloud manufacturing service provider based on grey correlation analysis and TOPSIS10.1080/00207543.2019.1600760 ↗
29. Experimental investigation of the mechanical properties of PTFE scrims under high temperature conditions10.1016/j.engfailanal.2021.105222 ↗
30. Effect of CNTs content on the mechanical and arc-erosion performance of Ag-CNTs composites10.1016/j.diamond.2022.109211 ↗
31. Investigation of the effect of different current loads on the arc-erosion performance of electrical contacts10.12693/APhysPolA.129.656 ↗
32. Sputtering by ion bombardment theoretical concepts10.1007/3540105212_7 ↗
33. Contact erosion in automotive DC relays10.1109/33.76517 ↗