journal article·1979-03

Lightweight, Durable-Press Cotton and Polyester/Cotton with Ignition Resistance

Wilson A. Reeves, Yvonne B. Marquette

Textile Research Journal· Volume 49· Issue 3
Publisher page

Abstract

A cotton broadcloth and a polyester/cotton broadcloth were successfully treated in the laboratory using a angle pad bath to impart fire resistance and durable press properties. A two catalyst system was used with rol 76, an oligomeric vinyl phosphonate, and either trimethylol acetylene diureine or dimethylol 4,5-dihydroxyethyleneurea in a pad dry cure process. Ignition resistance was determined by exposing the surface of treated fabrics to a small flamc for up to 12 s. Conventional tests were used to determine durable press properties.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Flame retardant materials and properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Louisiana Agricultural Experiment Station, School of Home Economics, Louisiana State University. Baton Rouge, LA 70803, U.S.A.

References (14)

Show source-provided references
1. American Association of Textile Chemists and Colorists · Test methods · 1969 · 124
2. American Society for Testing and Materials, (a D 1682 64, strip (one in.) method. (b) D 1295 67.
3. Braun, E. · 1976
4. Eisenberg, B.J. · Textile Chem. Color. · 1974 · 6 · 180
5. Federal Register · 1978 · 43 · 48
6. Federal Specifications CCC T 191b, Textile Test Method No. 5206.2.
7. McSherry, W.F. · Fire Retardant Chem. · 1975 · 2 · 151
8. 10.1177/15280837770060040710.1177/152808377700600407 ↗
9. Moreau, J.P. · J. Fire Retardant Chem. · 1977 · 4 · 5
10. Reeves, W.A. · Am. Dyest. Reptr. · 1978 · 67 · 64
11. 10.1177/00405175770470051010.1177/004051757704700510 ↗
12. Smitherman, J.E. · J. I ire Retardant Chem. · 1978 · 5 · 5
13. Tesoro, G.C. · J. · 1970 · 40 · 430
14. Tesoro, G.C. · Textile Chem. Color. · 1971 · 3 · 27