journal article·1985-11

Reference Standard Wool Tops for Measurement of Fiber Diameter Distribution

H.W.M. Lunney, G.H. Brown

Textile Research Journal· Volume 55· Issue 11
Publisher page

Abstract

The accurate measurement of the distribution of wool fiber diameter in a top using the projection microscope is described. The work is directed towards establishing the best way of generating reference standard tops. The fiber diameters are shown to conform to a lognormal distribution.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Textile materials and evaluations · Advanced Fluorescence Microscopy Techniques · Electron and X-Ray Spectroscopy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

CSIRO Division of Textile Physics, Ryde, NSW 2112, Australia

CSIRO Division of Mathematics and Statistics, Lindfield, NSW 2070. Australia

References (9)

Show source-provided references
1. Aitchison, J. · 1957
2. American Society for Testing and Materials, ASTM D-2130-66, Standard Method of Test for Diameter of Wool and Other Animal Fibers by Microprojection.
3. Anon. · Wool Sci. Rev. · 1952 · 8 · 33
4. Henon, R. · 1952
5. International Wool Textile Organization, Specification of Test Method 8-66, Method of Determining Wool Fiber Diameter by the Projection Microscope.
6. 10.1177/00405175820520031010.1177/004051758205200310 ↗
7. 10.1177/00405175830530050410.1177/004051758305300504 ↗
8. 10.1177/00405175600300080210.1177/004051756003000802 ↗
9. Monfort, F. "Scientific Aspects of the Woolen Industry" (in French), Dunod, Paris, 1960, pp. 174-179. Manuscript received April 16. 1985; accepted June 6, 1985.