A novel method for measuring in-plane liquid dynamic transport in fabric
Source abstract
Abstract
Fabric liquid dynamic transport capacity is a significant factor on the influence of human clothing comfort. In this study, we present a new approach to test in-plane liquid dynamic transport in a straightforward one-step procedure. In this method, a textile sample is irradiated by a radiation source during wetting. Meanwhile, the optical energy of the transmitted ray is transformed to voltage by a detector and is dynamically recorded by a computer. Eventually, the liquid spread speed and maximum absorption rate of the textile material are defined and obtained on the basis of the voltage. Compared with the standard instrument, the Moisture Management Tester, this new method provides more accurate measuring results for liquid spreading speeds and could be applicable for almost all liquid testing except for volatile fluid.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Textile materials and evaluations · Advanced Sensor and Energy Harvesting Materials · Thermoregulation and physiological responses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Textiles, Donghua University, P.R. China
Key Laboratory of Textile Science & Technology of Eco-Textile, Ministry of Education, Donghua University, P.R. China
References (18)
Show source-provided references
1. 10.1080/01694243.2015.103144310.1080/01694243.2015.1031443 ↗
2. 10.1016/j.carbon.2015.01.04110.1016/j.carbon.2015.01.041 ↗
3. 10.1021/am505170j10.1021/am505170j ↗
4. 10.1021/sc500320910.1021/sc5003209 ↗
5. 10.1016/j.ijheatmasstransfer.2006.06.03510.1016/j.ijheatmasstransfer.2006.06.035 ↗
6. 10.1080/10803548.2010.1107683910.1080/10803548.2010.11076839 ↗
7. 10.1016/0007-3628(72)90007-210.1016/0007-3628(72)90007-2 ↗
8. 10.1006/jmre.2002.254410.1006/jmre.2002.2544 ↗
9. 10.1063/1.161575710.1063/1.1615757 ↗
10. 10.1088/0957-0233/17/7/03410.1088/0957-0233/17/7/034 ↗
11. 10.1007/s11242-009-9488-910.1007/s11242-009-9488-9 ↗
12. 10.1016/j.jcis.2010.09.01510.1016/j.jcis.2010.09.015 ↗
13. 10.1080/10803548.2010.1107683910.1080/10803548.2010.11076839 ↗
14. Cleto, et al. Anlage zur feuchtigkeitsermittlung. EP 1615019-A1.
15. 10.1177/00405175050750011110.1177/004051750507500111 ↗
16. Weng S. Fourier transform infrared spectroscopy, Beijing: Chemical Industry Press, 2009, pp. 109–109.
17. 10.1177/004051751349005610.1177/0040517513490056 ↗
18. 10.1080/00405000.2010.52928510.1080/00405000.2010.529285 ↗