journal article·2013-01Open access

Effect of Tissue Specificity on the Performance of Extracellular Matrix in Improving Endothelialization of Cardiovascular Implants

Qiufen Tu, Zhilu Yang, Ying Zhu, Kaiqin Xiong, Manfred F. Maitz, Jin Wang, Yuancong Zhao, Nan Huang, Jian Jin, Yuechang Lei

Tissue Engineering Part A· Volume 19· Issue 1-2

Abstract

Natural extracellular matrix (ECM) deposited in situ by cultured endothelial cells (ECs) has been proven effective in accelerating endothelialization of titanium (Ti) cardiovascular implants (CVIs) in our previous studies. In this study, the ECM deposited by smooth muscle cells (SMCs) was used in comparison to investigate the effects of tissue specificity of the ECM on the ability to accelerate endothelialization of CVIs. The results demonstrated that the ECM deposited by ECs and SMCs (EC-ECM, SMC-ECM, respectively) differed considerably in components and fibril morphology. Surface modification of Ti CVIs with both types of natural ECM was effective in improving their in vitro hemocompatibility and cytocompatibility simultaneously. However, the endothelialization of ECM-modified Ti CVIs in a canine model demonstrated a high tissue specificity of the ECM. Although the ECM deposited by SMCs (SMC-ECM) induced fewer platelet adhesion and sustained better growth and viability of ECs in vitro, its performance in accelerating in vivo endothelialization of Ti CVIs was extremely poor. In contrast, the ECM deposited by ECs (EC-ECM) led to complete endothelium formation in vivo.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Key Laboratory of Advanced Technology of Materials, Education Ministry of China, Southwest Jiaotong University, Chengdu, China.

Max Bergmann Center for Biomaterials Dresden, Leibniz Institute for Polymer Research Dresden, Dresden, Germany.

Department of Cardiothoracic Surgery, Affiliated Hospital of Chengdu University, Chengdu, China.

References (40)

Show source-provided references
1. 10.1080/1073119050042828310.1080/10731190500428283 ↗
2. 10.1016/S0142-9612(00)00302-110.1016/S0142-9612(00)00302-1 ↗
3. 10.1016/j.actbio.2007.05.01210.1016/j.actbio.2007.05.012 ↗
4. 10.1006/exer.1997.031710.1006/exer.1997.0317 ↗
5. 10.1016/S0076-6879(08)02003-X10.1016/S0076-6879(08)02003-X ↗
6. 10.1016/j.jss.2009.03.01810.1016/j.jss.2009.03.018 ↗
7. 10.1016/j.actbio.2010.03.01910.1016/j.actbio.2010.03.019 ↗
8. 10.1016/j.biomaterials.2006.05.01810.1016/j.biomaterials.2006.05.018 ↗
9. 10.1016/j.athoracsur.2005.05.00210.1016/j.athoracsur.2005.05.002 ↗
10. 10.1002/jbm.b.3085010.1002/jbm.b.30850 ↗
11. 10.1089/ten.2005.11.157410.1089/ten.2005.11.1574 ↗
12. 10.1007/s10856-008-3377-610.1007/s10856-008-3377-6 ↗
13. 10.1109/10.93091010.1109/10.930910 ↗
14. 10.1016/j.bbrc.2003.11.14310.1016/j.bbrc.2003.11.143 ↗
15. 10.1083/jcb.99.3.94710.1083/jcb.99.3.947 ↗
16. 10.1089/ten.tea.2010.008810.1089/ten.tea.2010.0088 ↗
17. 10.1073/pnas.79.10.321310.1073/pnas.79.10.3213 ↗
18. 10.1016/j.biomaterials.2009.04.00510.1016/j.biomaterials.2009.04.005 ↗
19. 10.1172/JCI10747010.1172/JCI107470 ↗
20. 10.1021/jp801103n10.1021/jp801103n ↗
21. 10.1182/blood-2003-10-340110.1182/blood-2003-10-3401 ↗
22. 10.1016/j.jcin.2009.04.01710.1016/j.jcin.2009.04.017 ↗
23. 10.1016/j.jcin.2009.10.00410.1016/j.jcin.2009.10.004 ↗
24. 10.1016/j.yjmcc.2009.08.02410.1016/j.yjmcc.2009.08.024 ↗
25. 10.1016/S0934-8832(11)80192-710.1016/S0934-8832(11)80192-7 ↗
26. Hsieh P. · Invest Ophthalmol Vis Sci · 1985 · 26 · 457
27. 10.1161/01.ATV.6.1.2410.1161/01.ATV.6.1.24 ↗
28. 10.1016/S0006-291X(81)80087-310.1016/S0006-291X(81)80087-3 ↗
29. 10.1134/S1990519X0905013710.1134/S1990519X09050137 ↗
30. 10.1016/j.ejcb.2009.06.00110.1016/j.ejcb.2009.06.001 ↗
31. 10.1016/S0021-9150(98)00164-610.1016/S0021-9150(98)00164-6 ↗
32. 10.1006/jsre.1996.497810.1006/jsre.1996.4978 ↗
33. 10.1083/jcb.90.2.37210.1083/jcb.90.2.372 ↗
34. 10.1006/jsre.2001.616510.1006/jsre.2001.6165 ↗
35. 10.1006/jmcc.1997.054110.1006/jmcc.1997.0541 ↗
36. 10.1016/S1065-6995(03)00033-710.1016/S1065-6995(03)00033-7 ↗
37. 10.1016/j.biotechadv.2009.08.00210.1016/j.biotechadv.2009.08.002 ↗
38. 10.1016/S0142-9612(00)00153-810.1016/S0142-9612(00)00153-8 ↗
39. 10.1016/j.jtcvs.2007.01.02910.1016/j.jtcvs.2007.01.029 ↗
40. 10.1002/jcb.1015510.1002/jcb.10155 ↗