journal article·2016-12-21

Photonic Structure Textile Design for Localized Thermal Cooling Based on a Fiber Blending Scheme

Peter B. Catrysse, Alex Y. Song, Shanhui Fan

ACS Photonics· Volume 3· Issue 12
Publisher page

Abstract

There is great potential for energy savings in buildings if temperature set points of cooling systems can be extended by 1–2 °C (2–4 °F) provided that the thermal comfort of building occupants is maintained. Since most body heat is dissipated through thermal radiation, the photonic properties of textiles can play an essential role in localized thermal cooling. Current textiles are very opaque at infrared wavelengths and prevent the efficient transmission of thermal radiation from the human body when temperature set points are increased. In this work, we show a design approach for photonic structure textiles based on fiber materials that are both comfortable to wear and allow localized thermal cooling at increased set points. Our design principle is based on the blending of fibers that are largely infrared transparent to achieve efficient cooling and natural, infrared-opaque fibers for comfort of wearing. We use a full-vector electromagnetic field method to calculate our designs’ spectral, directional properties and we apply a detailed radiative heat transfer model based on a full spectral, directional net radiation method that we developed. We demonstrate that our designs, containing up to one-third cotton and two-thirds nylon, allow net heat transfer at an extended set point of 26.1 °C (79 °F) that exceeds the cooling abilities of a cotton-only design at the current thermal comfort set point of 23.9 °C (75 °F), which can result in more than 30% energy savings. We also find that the combined (radiative, convective and conductive) heat transfer for our designs at 26.1 °C (79 °F) exceeds the metabolic power rate of 58.2 W/m 2 for an adult in a sedentary state.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Thermal Radiation and Cooling Technologies · Urban Heat Island Mitigation · Building Energy and Comfort Optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Edward L. Ginzton Laboratory and Department of Electrical Engineering, Stanford University, Stanford, California 94305, United States

Funding

U.S. Department of Energy

References (30)

Show source-provided references
1. Mayernik, J.Buildings Energy Data Book. U.S. Dept. of Energy;Office of Energy Efficiency and Renewable Energy:Washington, D.C., 2012.
2. Conti J. J. · 2015
3. Fanger P. O. · 1970
4. Hoyt, T.; Lee, K. H.; Zhang, H.; Arens, E.; Webster, T.,Energy savings from extended air temperature setpoints and reductions in room air mixing.Proceedings of the 13th International Conference on Environmental Ergonomics, Boston, MA, 2009; Vol.13.
5. ANSI/ASHRAE, Standard 55–2013: Thermal Environmental Conditions for Human Occupancy;ASHRAE, 2013.
7. 10.1073/pnas.23.12.62410.1073/pnas.23.12.624 ↗
8. Winslow C. E. A. · Am. J. Physiol. · 1939 · 127 · 50510.1152/ajplegacy.1939.127.3.505 ↗
9. 10.1007/s00484005003510.1007/s004840050035 ↗
10. 10.1038/nature1388310.1038/nature13883 ↗
11. 10.1126/science.aab356410.1126/science.aab3564 ↗
12. 10.1021/nl400428310.1021/nl4004283 ↗
13. 10.1063/1.483599510.1063/1.4835995 ↗
14. 10.1073/pnas.150945311210.1073/pnas.1509453112 ↗
15. Mason M. · 1967
16. 10.1021/acsphotonics.5b0014010.1021/acsphotonics.5b00140 ↗
17. 10.1126/science.aaf547110.1126/science.aaf5471 ↗
18. Silverstein R. M. · 2015
19. Stuart B. H. · 2005
20. 10.1080/0014013950892517810.1080/00140139508925178 ↗
21. 10.1016/S0142-9418(01)00124-610.1016/S0142-9418(01)00124-6 ↗
22. 10.1021/jp035731a10.1021/jp035731a ↗
23. 10.1364/AO.51.00632510.1364/AO.51.006325 ↗
24. Siegel R. · 2002
25. Modest M. F. · 2013
26. Sparrow E. M. · 1966
27. Hottel H. C. · 1967
28. Siegel, R.Net radiation method for enclosure systems involving partially transparent walls.N-73-28915; NASA-TN-D-7384; E-7365;NASA:Washington, D.C., 1973.
29. 10.1016/j.cpc.2012.04.02610.1016/j.cpc.2012.04.026 ↗
30. 10.2514/2.680210.2514/2.6802 ↗