Fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva containing varying concentrations of fluoride ions
Source abstract
Abstract
Abstract The present communication addresses the fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva containing 0, 190, 570 and 1140 ppm of fluoride ions. The fretting corrosion behaviour of Ti–6Al–4V alloy was evaluated based on the change in free corrosion potential (FCP) measured as a function of time. The wear morphology and surface profile of the fretted zone, assessed by scanning electron microscopy and non-contact optical profilometer, were used to ascertain the wear mechanism. The cathodic shift in FCP observed with the onset of fretting indicates damage of the passive film. After the fretting motion is ceased, an instantaneous repassivation of Ti–6Al–4V alloy is observed only in artificial saliva. The negative influence of fluoride ions on passive film formation hinders instantaneous repassivation of the damaged areas of the fretted zone. The morphology of the fretted zone reveals the occurrence of adhesive galling in all the cases. The wear volume of the fretted zone of Ti–6Al–4V alloy in artificial saliva free of fluoride ions is 3.26 × 10 12 nm 3 . In presence of 190 ppm of fluoride ions in artificial saliva, the wear volume is increased from 3.26 to 9.87 × 10 12 nm 3 . However, the wear volume is reduced to 6.95 × 10 12 nm 3 and 3.60 × 10 11 nm 3 at 570 and 1140 ppm of fluoride ions, respectively. The change in contact configuration from alumina–titanium to titanium-coated alumina–titanium reduced the mutual solubility between alumina and titanium, the extent of trapping and grinding of the wear debris and the wear rate of Ti–6Al–4V alloy in artificial saliva containing 1140 ppm of fluoride ions. The study reveals that the fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva shows a strong dependence on the fluoride ion concentration.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Mechanical stress and fatigue analysis · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Titanium alloys in total joint replacement – a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
2. Surface modification of titanium, titanium alloys, and related materials for biomedical applications10.1016/j.mser.2004.11.001 ↗
3. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
4. Wear of titanium by soft tissue
5. Corrosion of highly stressed orthopaedic joint replacements
6. In vitro studies of fretting corrosion of orthopaedic materials10.1002/jor.1100060415 ↗
7. Fretting in orthopaedic implants: a review10.1016/0043-1648(94)90272-0 ↗
8. Fretting deterioration of orthopaedic implant materials: search for solution10.1016/0267-6605(94)90049-3 ↗
9. Significance of tribocorrosion in biomedical applications: overview and current status10.1155/2009/250986 ↗
10. Fretting corrosion mechanisms at modular hip implant interfaces
11. Design of dynamic test equipment for the testing of dental implants10.1016/S0261-3069(04)00154-2 ↗
12. Fretting in prosthetic devices related to human body10.1016/j.triboint.2009.04.007 ↗
13. Tribocorrosion behavior of plasma nitrided Ti–6Al–4V alloy in neutral NaCl solution10.1016/S0257-8972(01)01309-3 ↗
14. Fretting-corrosion of materials used as orthopaedic implants10.1016/j.wear.2004.11.027 ↗
15. Tribo-electrochemical technique for studying tribocorrosion behavior of biomaterials10.1016/j.bioeng.2007.07.015 ↗
16. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
17. Improvement of corrosion wear resistance of Ti–6Al–4V alloy by plasma Mo–N surface modification10.1002/adem.200400207 ↗
18. Effect of sliding wear on tribocorrosion behaviour of stainless steels in a Ringer's solution10.1016/j.wear.2006.03.003 ↗
19. Fretting corrosion resistance and fretting corrosion product cytocompatibility of ferritic stainless steel10.1002/(SICI)1097-4636(199701)34:1<9::AID-JBM2>3.0.CO;2-V ↗
20. Corrosion-wear monitoring of TiN coated AISI 316 stainless steel by electrochemical noise measurements10.1016/j.apsusc.2006.01.062 ↗
21. Electrochemical techniques for studying tribocorrosion processes10.1016/S0043-1648(03)00556-8 ↗
22. Electrochemical noise measurements on stainless steel during corrosion-wear in sliding contacts10.1016/S0043-1648(03)00558-1 ↗
23. Fretting corrosion of materials for orthopaedic implants: a study of a metal/polymer contact in an artificial physiological medium10.1016/S0301-679X(99)00099-7 ↗
24. Tribo-corrosion properties of cobalt-based medical implant alloys in simulated biological environments10.1016/j.wear.2007.01.114 ↗
25. Fretting corrosion behaviour of thermally oxidized CP-Ti in Ringer's solution10.1016/j.corsci.2009.10.029 ↗
26. Evaluation of fretting corrosion behaviour of CP-Ti for orthopaedic implant applications10.1016/j.triboint.2009.12.007 ↗
27. Fretting-corrosion mapping of CP-Ti in Ringer's solution10.1016/j.wear.2010.01.026 ↗
28. Influence of pH and corrosion inhibitors on the tribocorrosion of titanium in artificial saliva10.1016/j.wear.2006.03.031 ↗
29. Corrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions10.4012/dmj.20.305 ↗
30. Effects of fluoride prophylactic agents on titanium surfaces
31. Influence of fluoride on titanium in an acidic environment measured by polarization resistance technique10.1002/jab.770060409 ↗
32. Corrosive properties of fluoride-containing odontologic gels against titanium10.1016/0300-5712(95)00033-X ↗
33. Effects of fluorides on titanium and other dental alloys in dentistry10.1016/S0142-9612(97)00179-8 ↗
34. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys10.1016/S0142-9612(01)00328-3 ↗
35. Effects of fluoride and albumin concentration on the corrosion behavior of Ti–6Al–4V alloy10.1016/S0142-9612(02)00315-0 ↗
36. Corrosion behavior of a new titanium alloy for dental implant applications in fluoride media10.1016/j.matchemphys.2004.03.019 ↗
37. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments10.1016/j.biomaterials.2004.07.022 ↗
38. Effect of acidic fluoride solution on β-titanium alloy wire10.1002/jbm.b.30212 ↗
39. Corrosion behaviour of Ti–15Mo alloy for dental implant applications10.1016/j.jdent.2008.03.007 ↗
40. Influence of fluoride ion on the electrochemical behaviour of β-Ti alloy for dental implant application10.1016/j.corsci.2010.01.008 ↗
41. Fretting wear of ceramics10.1016/0301-679X(89)90169-2 ↗