Effect of grain size and crystallographic structure on the corrosion and tribocorrosion behaviour of a CoCrMo biomedical grade alloy in simulated body fluid
Source abstract
Abstract
CoCrMo alloys are used in hip and knee replacements due to their excellent long-term survival rates. However, high failure rates have recently been observed associated with adverse tissue reactions. CoCrMo alloy surfaces undergo microstructural changes during wear, including the formation of ε-martensite and, occasionally, a nanocrystalline surface layer. It is not clear whether these changes are beneficial or detrimental to the performance of the component. Thus, high-pressure torsion (HPT) was employed to produce different grain sizes and crystallographic structures in a CoCrMo alloy and the corrosion and tribocorrosion behaviour were critically investigated as a function of grain size. The results reveal a degradation of the corrosion resistance for the HTP processed samples. The contributions of mechanical and corrosion material loss in tribocorrosion is also examined.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Metal Alloys Wear and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. The long-term wear of retrieved McKee-Farrar metal-on-metal total hip prostheses10.1016/j.arth.2004.09.028 ↗
2. In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use
3. Results of Birmingham hip resurfacing at 12 to 15 years10.1302/0301-620X.96B10.33695 ↗
4. Five-year results of the ASR XL acetabular system and the ASR hip resurfacing system: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry10.2106/JBJS.J.01727 ↗
5. Failure rates of metal-on-metal hip resurfacings: analysis of data from the national joint registry for england and wales10.1016/S0140-6736(12)60989-1 ↗
6. Engineering issues and wear performance of metal on metal hip implants10.1097/00003086-199612000-00009 ↗
7. The acting wear mechanisms on metal-on-metal hip joint bearings: in vitro results10.1016/S0043-1648(01)00654-8 ↗
8. Dynamic surface microstructural changes during tribological contact that determine the wear behaviour of hip prostheses: metals and ceramics10.1039/c2fd00002d ↗
9. Micro-structural alterations within different areas of articulating surfaces of a metal-on-metal hip resurfacing system10.1016/j.wear.2009.01.012 ↗
10. Subsurface characterisation of wear on mechanically polished and electro-polished biomedical grade CoCrMo10.1016/j.wear.2015.02.007 ↗
11. The pathways of dynamic recrystallization in all-metal hip joints10.1016/j.wear.2005.02.036 ↗
12. The tribological difference between biomedical steels and CoCrMo-alloys10.1016/j.jmbbm.2012.01.007 ↗
13. Tribochemical reaction on metal-on-metal hip joint bearings A comparison between in-vitro and in-vivo results10.1016/S0043-1648(03)00127-3 ↗
14. Correlation of the wear transition in CoCrMo alloys with the formation of a nanocrystalline surface layer and a proteinaceous surface film10.1016/j.wear.2016.11.046 ↗
15. Electrochemical polarisation and corrosion behaviour of cobalt and Co(W,C) alloys in 1 N sulphuric acid10.1016/S0921-5093(97)00492-9 ↗
16. “Corrosion resistance and microstructure of electrodeposited nickel–cobalt alloy coatings10.1016/j.surfcoat.2006.06.017 ↗
17. Corrosion behaviour of CoCrMo alloys in 2 wt% sulphuric acid solution10.1016/j.electacta.2014.01.143 ↗
18. Tribocorrosion in implants-assessing high carbon and low carbon Co-Cr-Mo alloys by in situ electrochemical measurements10.1016/j.triboint.2006.01.016 ↗
19. Understanding the role of corrosion in the degradation of metal-on-metal implants10.1243/095441105X63246 ↗
20. The evolution of homogeneity in an aluminum alloy processed using high-pressure torsion10.1016/j.actamat.2008.06.036 ↗
21. Influence of strain rate on the characteristics of a magnesium alloy processed by high-pressure torsion10.1016/j.msea.2011.01.066 ↗
22. Using finite element modeling to examine the flow processes in quasi-constrained high-pressure torsion10.1016/j.msea.2011.07.040 ↗
23. “Méthode d’analyse quantitative des variétés allotropiques du cobalt par les rayons X10.1051/metal/195047020139 ↗
24. Ma · 2010
25. Lentner · 2014 · 1
26. Y. C. Wang and T. G. Langdon, “Influence of phase volume fractions on the processing of a Ti–6Al–4V alloy by high-pressure torsion,” Mater. Sci. Eng., A, vol. 559, pp. 861–867, Jan. 2013, doi: 10.1016/J.MSEA.2012.09.034.10.1016/j.msea.2012.09.034 ↗
27. H. Shahmir, F. Naghdi, P. H. R. Pereira, Y. Huang, and T. G. Langdon, “Factors influencing superplasticity in the Ti-6Al-4V alloy processed by high-pressure torsion,” Mater. Sci. Eng., A, vol. 718, pp. 198–206, Mar. 2018, doi: 10.1016/J.MSEA.2018.01.091.10.1016/j.msea.2018.01.091 ↗
28. The influence of protein concentration, temperature and cathodic polarization on the surface status of CoCrMo biomedical grade alloys10.1016/j.apsusc.2019.143908 ↗
29. R. Namus and W. M. Rainforth, “Influence of protein adsorption on tribocorrosion behaviour of CoCrMo biomedical-grade alloys,” Tribol. Int., p. 106364, Apr. 2020, doi: 10.1016/J.TRIBOINT.2020.106364.10.1016/j.triboint.2020.106364 ↗
30. Hutchings · 1992
31. Tribocorrosion mechanisms in sliding contacts
32. Davis · 2000
33. A. C. C. Vieira, L. A. A. Rocha, N. Papageorgiou, and S. Mischler, “Mechanical and electrochemical deterioration mechanisms in the tribocorrosion of Al alloys in NaCl and in NaNO3 solutions,” Corrosion Sci., vol. 54, no. 1, pp. 26–35, Jan. 2012, doi: 10.1016/j.corsci.2011.08.041.10.1016/j.corsci.2011.08.041 ↗
34. Electrochemical simulation of the current and potential response in sliding tribocorrosion10.1007/s11249-012-0022-9 ↗
35. Mischler
36. Fischer-Cripps · 2007
37. “Nanoindentation stress–strain curves as a method for thin-film complete mechanical characterization: application to nanometric CrN/Cr multilayer coatings10.1007/s00339-002-1669-0 ↗
38. Revealing the relationship between grain size and corrosion rate of metals10.1016/j.scriptamat.2010.08.035 ↗
39. Passive behavior of a bulk nanostructured 316L austenitic stainless steel consisting of nanometer-sized grains with embedded nano-twin bundles10.1016/j.corsci.2014.04.039 ↗
40. Surface modifications induced in 316L steel by laser peening and shot-peening
41. Corrosion resistance of ultra fine-grained Ti10.1016/j.scriptamat.2004.04.011 ↗
42. Mechanical and wear properties of ultrafine-grained pure Ti produced by multi-pass equal-channel angular extrusion10.1016/j.msea.2009.03.054 ↗
43. Wear behaviour of Al-1050 alloy processed by severe plastic deformation10.4028/www.scientific.net/MSF.667-669.1101 ↗
44. Effect of equal-channel angular extrusion on mechanical and wear properties of eutectic Al-12Si alloy10.1016/j.matdes.2009.08.004 ↗
45. Electrochemical quartz crystal microbalance and X-ray photoelectron spectroscopy study of cathodic reactions in bovine serum albumin containing solutions on a physical vapour deposition-CoCrMo biomedical alloy10.1016/j.electacta.2015.08.017 ↗
46. Namus · 2018
47. Microstructural effects on the wear resistance of wrought and as-cast Co-Cr-Mo-C implant alloys10.1002/jbm.a.30392 ↗
48. Pelton · 2004 · 199