In situ monitoring and prediction of progressive joint wear using Bayesian statistics
Source abstract
Abstract
In this paper, a statistical methodology of estimating wear coefficient and predicting wear volume in a revolute joint using in situ measurement data is presented. An instrumented slider–crank mechanism that can measure the joint force and the relative motion between the pin and bushing is built. The former is measured using a load cell built onto a necked portion of the hollow steel pin, while the latter is measured using a capacitance probe. In order to isolate the effect of friction in other joints, a porous carbon air bearing for the revolute joint between the follower link and the slide stage, as well as a prismatic joint for the linear slide, are used. Based on the relative motion between the centers of the pin and bushing, the wear volumes are estimated at six different operating cycles. The Bayesian inference technique is used to update the distribution of wear coefficients, which incorporates in situ measurement data to obtain the posterior distribution. The Markov Chain Monte Carlo technique is employed to generate samples from the given distribution. The results show that it is possible to narrow the distribution of wear coefficients and to predict the future wear volume with reasonable confidence. The effect of the prior distribution on the wear coefficient is discussed by comparing with the non-informative case.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical stress and fatigue analysis · Gear and Bearing Dynamics Analysis · Fatigue and fracture mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (18)
Show source-provided references
1. Finite element analysis and validation of metal/metal wear in oscillatory contacts10.1016/j.wear.2004.12.014 ↗
2. Finite element analysis wear simulation of a conical spinning contact considering surface topography10.1016/S0043-1648(98)00318-4 ↗
3. Simulating sliding wear with finite element method10.1016/S0301-679X(99)00012-2 ↗
4. The relationship between contact pressure, insert thickness, and mild wear in total knee replacements
5. Comparison between elastic foundation and contact force models in wear analysis of planar multibody system10.1115/1.4001786 ↗
6. Wear rate uncertainty analysis10.1115/1.1792675 ↗
7. Analysis of planar multibody systems with revolute joint wear10.1016/j.wear.2009.10.014 ↗
8. An instrumented crank–slider mechanism for validation of a combined finite element and wear model
9. Gelman · 2004
10. Contact and rubbing of flat surfaces10.1063/1.1721448 ↗
11. Wear-mechanism maps10.1016/0001-6160(87)90209-4 ↗
12. Numerical simulation of wear-mechanism maps10.1016/S0927-0256(02)00249-5 ↗
13. Holm · 1946
14. Bayesian analysis of a generalized lognormal distribution10.1016/j.csda.2008.11.029 ↗
15. Robustifying Bayesian procedures
16. An introduction to MCMC for machine learning10.1023/A:1020281327116 ↗
17. Comparison of methodologies to assess the convergence of Markov Chain Monte Carlo methods10.1016/j.csda.2005.04.018 ↗
18. CODA: convergence diagnosis and output analysis for MCMC