journal article·2008-05

Special modes of corrosion under physiological and simulated physiological conditions

S. Virtanen, I. Milošev, E. Gomez-Barrena, R. Trebše, J. Salo, Y.T. Konttinen

Acta Biomaterialia· Volume 4· Issue 3
Publisher page

Abstract

The aim of this article is to review those aspects of corrosion behaviour that are most relevant to the clinical application of implant alloys. The special modes of corrosion encountered by implant alloys are presented. The resistance of the different materials against the most typical corrosion modes (pitting corrosion, crevice corrosion and fretting corrosion) is compared, together with observations of metal ion release from different biomaterials. A short section is dedicated to possible galvanic effects in cases when different types of materials are combined in a biomedical device. The different topics covered are introduced from the viewpoint of materials science, and then placed into the context of medicine and clinical experience.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (75)

Show source-provided references
1. Ratner · 2004
2. Williams DF. Biofunctionality and Biocompatibility. In: Cahn RW, Haasen P, Kramer EJ, editors. Materials science and technology. A comprehensive treatment. vol. 14: Medical and dental materials. Weinheim: VCH; 1992. p. 2–26.
3. Biomedical surface science: foundations to frontiers10.1016/S0039-6028(01)01587-4 ↗
4. Biological surface science10.1016/S0039-6028(01)01809-X ↗
5. Fraker AC. Corrosion of metallic implants and prosthesis devices. In: ASTM metals handbook (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987, p. 1324–35.
6. Leclerc MF. Surgical implants. In: ASTM metals handbook (9th ed.) vol. 2. Metals Park, OH: ASM International; 1987, p. 164–80.
7. Corrosion of metal orthopaedic implants
8. Metal implants and surface reactions10.1016/0020-1383(96)89027-9 ↗
9. Stability, reactivity and breakdown of passive films. Problems of recent and future research10.1016/S0013-4686(00)00347-9 ↗
10. From Bacon to barriers: a review on the passivity of metals and alloys10.1007/s100080100219 ↗
11. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
12. The behavior of stainless steels in physiological solution containing complexing agent studied by X-ray photoelectron spectroscopy10.1002/1097-4636(200011)52:2<404::AID-JBM22>3.0.CO;2-Z ↗
13. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution10.1016/S0013-4686(03)00396-7 ↗
14. Preparation and assessment of revised simulated body fluids10.1002/jbm.a.10482 ↗
15. Biotribocorrosion of CoCrMo orthopaedic implant materials: assessing the formation and effect of the biofilm10.1016/j.triboint.2007.02.019 ↗
16. The influence of complexing agent and proteins on the corrosion of stainless steels and their metallic components10.1023/A:1021505621388 ↗
17. Milošev I. The effect of complexing agents on the electrochemical behaviour of orthopaedic stainless steel in physiological solution. J Appl Electrochem 1002;32:311–20.10.1023/A:1015595420097 ↗
18. Electrochemical studies of the adsorption behavior of bovine serum albumin on stainless steel10.1021/la990474f ↗
19. Competitive binding to chromium, cobalt and nickel to serum proteins10.1016/0142-9612(94)90049-3 ↗
20. The corrosion behaviour of Ti–6Al–4V, Ti–6Al–7Nb and Ti–13Nb–13Zr in protein solution10.1016/S0142-9612(98)00217-8 ↗
21. Characterization of implant materials in fetal bovine serum and sodium sulphate by electrochemical impedance spectroscopy. I. Mechanically polished samples10.1002/jbm.10329 ↗
22. Electrochemical corrosion properties of Ti–6Al–4V implant alloy in biological environment10.1016/j.msea.2004.03.069 ↗
23. Biomaterials: the interfacial problem10.1016/B978-0-12-004905-9.50007-4 ↗
24. Crevice corrosion of cemented titanium alloy stems in total hip replacements10.1097/00003086-199612000-00006 ↗
25. Acid attack and cathepsin K in bone resorption around total hip replacement prosthesis10.1359/jbmr.2001.16.10.1780 ↗
26. Wear: osteolysis related to metallic debris
27. Metallic shedding, surface finish changes, and extensive femoral osteolysis in the loose Spectron EF stem10.1097/01.blo.0000181145.01306.f9 ↗
28. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants10.1097/00003086-199203000-00010 ↗
29. Sedriks · 1996
30. Cutaneous metal sensitivity in patients with orthopaedic injuries10.1097/00005131-200102000-00002 ↗
31. The properties and clinical uses of cobalt–chromium alloys
32. Asphahani AI. Corrosion of cobalt base alloys. In: ASM Metals Handbook. (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987. p. 658–68.
33. Cobalt alloys
34. Late fatigue fracture of a modern cemented forged cobalt chrome stem for total hip arthroplasty: a report of 10 cases10.1016/j.arth.2005.03.038 ↗
35. The corrosion properties of titanium and titanium alloys
36. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen-peroxide10.1002/jbm.820280115 ↗
37. Electrochemcial impedance spectroscopy study of the passive oxide film on titanium for implant application10.1016/0013-4686(95)00465-3 ↗
38. Ruzickova M, Hildebrand, H, Virtanen S. Z Phys Chem 2005;219:1447–59.10.1524/zpch.2005.219.11.1447 ↗
39. Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases10.1016/0883-5403(92)90056-V ↗
40. Particulate titanium and cobalt–chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis10.1016/0883-5403(94)90084-1 ↗
41. Complications of femoral and acetabular modularity
42. Zsklarska-Smialowska Z. Pitting corrosion of metals. Houston, TX: National Association of Corrosion Engineers; 1986.
43. Passive and transpassive behaviour of CoCrMo in simulated biological solutions10.1016/j.electacta.2003.12.043 ↗
44. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution10.1016/j.biomaterials.2004.02.023 ↗
45. Metastable and stable pitting corrosion of titanium in halide solutions
46. Observations of localized instability of passive titanium in chloride solution10.1016/0013-4686(95)00126-Y ↗
47. A preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro10.1007/BF00154545 ↗
48. Origins of pitting corrosion10.1179/147842204225016859 ↗
49. An electrochemical investigation of localized corrosion on titanium in chloride environments10.5006/1.3581969 ↗
50. Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. In: Metals handbook (9th ed.) vol. 13. Metals Park, OH: ASM International; 1987. p. 669–706.
51. Fretting corrosion accelerates crevice corrosion of modular hip tapers10.1002/jab.770060104 ↗
52. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combination. The effect of crevice, stress, motion and alloy coupling10.1002/jbm.820271210 ↗
53. Conjoint corrosion and wear in titanium alloys10.1016/S0142-9612(98)00229-4 ↗
54. Investigation into wear-induced corrosion of orthopedic implant materials
55. Environmental effect on fretting of metallic materials for orthopaedic implants10.1016/S0043-1648(03)00522-2 ↗
56. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
57. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
58. Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method10.1002/(SICI)1097-4636(19971205)37:3<421::AID-JBM13>3.0.CO;2-E ↗
59. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid10.1002/(SICI)1097-4636(19980615)40:4<530::AID-JBM3>3.0.CO;2-G ↗
60. Hip implants – paper VI – ion concentrations10.1016/j.matdes.2005.05.018 ↗
61. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
62. Comparison of metal release from various metallic biomaterials in vitro10.1016/j.biomaterials.2004.02.005 ↗
63. Comparison of metal concentrations in rat tibia tissues with various metallic implants10.1016/j.biomaterials.2004.01.064 ↗
64. Release of hexavalent chromium from corrosion of stainless steel and cobalt–chromium alloys10.1002/jbm.820290510 ↗
65. Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty10.1302/0301-620X.87B10.16541 ↗
66. Serum cobalt levels after metal-on-metal total hip arthroplasty10.2106/00004623-200311000-00017 ↗
67. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements10.1016/S0736-0266(02)00152-3 ↗
68. Massive wear of an incompatible metal-on-metal articulation in total hip arthroplasty10.1016/j.arth.2003.12.076 ↗
69. The use of dissimilar metals in surgery10.1002/jbm.820090417 ↗
70. Mansfeld F, Lee CC, Kovacs P. Application of electrochemical impedance spectroscopy (EIS) to the evaluation of the corrosion behavior of implant materials. In: Kovacs P, Istephanous NS, editors. Compatibility of biomedical implants, Pennington, NJ: The Electrochemical Society; 1994. p. 59–72.
71. The contribution of metallic debris to osteolysis10.3928/0147-7447-19940901-05 ↗
72. An analysis of the head–neck taper interface in retrieved hip prostheses10.1097/00003086-199403000-00021 ↗
73. Corrosion at the interface. A possible solution to cobalt–chrome heads on titanium alloy stems10.1016/S0883-5403(05)80010-5 ↗
74. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material10.1016/S0142-9612(02)00055-8 ↗
75. Is galvanic corrosion between titanium alloy and stainless steel spinal implant a clinical concern?10.1016/j.spinee.2003.12.004 ↗