Young’s modulus of trabecular bone at the tissue level: A review
Source abstract
Abstract
The tissue-level Young's modulus of trabecular bone is important for detailed mechanical analysis of bone and bone-implant mechanical interactions. However, the heterogeneity and small size of the trabecular struts complicate an accurate determination. Methods such as micro-mechanical testing of single trabeculae, ultrasonic testing, and nanoindentation have been used to estimate the trabecular Young's modulus. This review summarizes and classifies the trabecular Young's moduli reported in the literature. Information on species, anatomic site, and test condition of the samples has also been gathered. Advantages and disadvantages of the different methods together with recent developments are discussed, followed by some suggestions for potential improvement for future work. In summary, this review provides a thorough introduction to the approaches used for determining trabecular Young's modulus, highlights important considerations when applying these methods and summarizes the reported Young's modulus for follow-up studies on trabecular properties. Statement of significance The spongy trabecular bone provides mechanical support while maintaining a low weight. A correct measure of its mechanical properties at the tissue level, i.e. at a single-trabecula level, is crucial for analysis of interactions between bone and implants, necessary for understanding e.g. bone healing mechanisms. In this study, we comprehensively summarize the Young's moduli of trabecular bone estimated by currently available methods, and report their dependency on different factors. The critical review of different methods with recent updates is intended to inspire improvements in estimating trabecular Young's modulus. It is strongly suggested to report detailed information on the tested bone to enable statistical analysis in the future.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone health and osteoporosis research · Bone Metabolism and Diseases · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
2. Molecular mechanics of mineralized collagen fibrils in bone10.1038/ncomms2720 ↗
3. Structural orientation dependent sub-lamellar bone mechanics10.1016/j.jmbbm.2015.02.031 ↗
4. A three-scale finite element investigation into the effects of tissue mineralisation and lamellar organisation in human cortical and trabecular bone10.1016/j.jmbbm.2012.03.003 ↗
5. Role of collagen and other organics in the mechanical properties of bone
6. Constitutive relationships of fabric, density, and elastic properties in cancellous bone architecture10.1016/S8756-3282(99)00190-8 ↗
7. Anisotropy and inhomogeneity of the trabecular structure can describe the mechanical strength of osteoarthritic cancellous bone10.1016/j.jbiomech.2009.11.034 ↗
8. Review Micromechanical testing of bone trabeculae - potentials and limitations10.1023/A:1026748913553 ↗
9. Indentation of bone tissue: a short review10.1007/s00198-009-0854-9 ↗
10. Towards patient-specific material modeling of trabecular bone post-yield behavior10.1002/cnm.2516 ↗
11. Nature’s hierarchical materials10.1016/j.pmatsci.2007.06.001 ↗
12. N. Mathavan, The Anabolic – Anti-catabolic Paradigm of Augmenting Skeletal Regeneration: A Bone Quality Perspective, Department of Biomedical Engineering, Lund University, Lund, 2017, p. 248
13. Is a sample size of n=6 a 'magic' number?
14. Buckling studies of single human trabeculae10.1016/0021-9290(75)90025-1 ↗
15. The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus10.1016/0021-9290(90)90003-L ↗
16. A comparison of the fatigue behavior of human trabecular and cortical bone tissue10.1016/0021-9290(92)90051-2 ↗
17. Increased calcium content and inhomogeneity of mineralization render bone toughness in osteoporosis: Mineralization, morphology and biomechanics of human single trabeculae10.1016/j.bone.2009.08.002 ↗
18. Mechanical properties of single bovine trabeculae are unaffected by strain rate10.1016/j.jbiomech.2010.12.008 ↗
19. Stress-concentrating effect of resorption lacunae in trabecular bone10.1016/j.jbiomech.2004.12.027 ↗
20. On the dependence of the elasticity and strength of cancellous bone on apparent density10.1016/0021-9290(88)90008-5 ↗
21. Micro-cantilever bending for elastic modulus measurements of a single trabecula in cancellous bone10.1016/j.jbiomech.2016.10.016 ↗
22. Viscoelastic behaviour and failure of bovine cancellous bone under constant strain rate10.1016/j.jbiomech.2004.11.005 ↗
23. Nanostructure and elastic modulus of single trabecula in bovine cancellous bone10.1016/j.jbiomech.2014.09.009 ↗
24. Tensile testing of rodlike trabeculae excised from bovine femoral bone10.1016/0021-9290(89)90049-3 ↗
25. Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
26. Nanoindentation of trabecular bone-comparison with uniaxial testing of single trabecula
27. Microtensile measurements of single trabeculae stiffness in human femur10.1016/S0021-9290(02)00182-3 ↗
28. Elastic moduli and poisson’s ratios of microscopic human femoral trabeculae
29. Within subject heterogeneity in tissue-level post-yield mechanical and material properties in human trabecular bone10.1016/j.jmbbm.2013.04.014 ↗
30. Novel method to analyze post-yield mechanical properties at trabecular bone tissue level10.1016/j.jmbbm.2012.12.003 ↗
31. The influence of boundary conditions and loading mode on high-resolution finite element-computed trabecular tissue properties10.1016/j.bone.2008.11.015 ↗
32. Comparison of the trabecular and cortical tissue moduli from human iliac crests10.1002/jor.1100070614 ↗
33. A new device and method for measuring the elastic modulus of single trabeculae10.1016/j.medengphy.2011.03.012 ↗
34. Local strain and damage mapping in single trabeculae during three-point bending tests10.1016/j.jmbbm.2010.12.009 ↗
35. Indirect determination of material model parameters for single trabecula based on nanoindentation and three-point bending test
36. An ultrasonic method for measuring the elastic properties of human tibial cortical and cancellous bone10.1016/S0041-624X(96)00078-9 ↗
37. Structural and material mechanical properties of human vertebral cancellous bone10.1016/S1350-4533(97)00030-1 ↗
38. Elastic modulus of trabecular bone material10.1016/0021-9290(88)90167-4 ↗
39. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques10.1016/S0021-9290(98)00177-8 ↗
40. Assessment of trabecular bone tissue elasticity with resonant ultrasound spectroscopy10.1016/j.jmbbm.2017.05.037 ↗
41. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
42. The effects of embedding material, loading rate and magnitude, and penetration depth in nanoindentation of trabecular bone10.1002/jbm.a.30742 ↗
43. Atomic force microscopy and nanoindentation characterization of human lamellar bone prepared by microtome sectioning and mechanical polishing technique10.1002/jbm.a.10109 ↗
44. Effects of surface roughness and maximum load on the mechanical properties of cancellous bone measured by nanoindentation10.1002/jbm.a.30633 ↗
45. Nanoindentation discriminates the elastic properties of individual human bone lamellae under dry and physiological conditions10.1016/S8756-3282(01)00624-X ↗
46. Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation10.1016/S0142-9612(97)00073-2 ↗
47. Elastic properties of microstructural components of human bone tissue as measured by nanoindentation10.1002/(SICI)1097-4636(199904)45:1<48::AID-JBM7>3.0.CO;2-5 ↗
48. The use of nanoindentation for characterizing the properties of mineralized hard tissues: State-of-the art review10.1002/jbm.b.31092 ↗
49. Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur10.1016/S0021-9290(99)00111-6 ↗
50. Age, gender, and bone lamellae elastic moduli10.1002/jor.1100180315 ↗
51. Heterogeneity of bone lamellar-level elastic moduli10.1016/S8756-3282(00)00268-4 ↗
52. Elastic modulus and hardness of cortical and trabecular bovine bone measured by nanoindentation10.1016/S1003-6326(06)60293-8 ↗
53. Mechanical properties of OI type III bone tissue measured by nanoindentation10.1002/jbm.a.30713 ↗
54. Comparison of nanoindentation measurements between osteogenesis imperfecta Type III and Type IV and between different anatomic locations (Femur/Tibia versus Iliac Crest)10.1080/03008200601090949 ↗
55. Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation10.1016/j.jbiomech.2007.05.004 ↗
56. Micromechanical properties of human trabecular bone: a hierarchical investigation using nanoindentation10.1002/jbm.a.31766 ↗
57. Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties10.1016/j.jbiomech.2008.05.014 ↗
58. Precision of nanoindentation protocols for measurement of viscoelasticity in cortical and trabecular bone10.1016/j.jbiomech.2010.04.017 ↗
59. Valid μ finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions10.1016/j.jbiomech.2010.02.026 ↗
60. Rehydration of vertebral trabecular bone: Influences on its anisotropy, its stiffness and the indentation work with a view to age, gender and vertebral level10.1016/j.bone.2009.09.035 ↗
61. The role of mineral content in determining the micromechanical properties of discrete trabecular bone remodeling packets10.1016/j.jbiomech.2010.07.038 ↗
62. Mechanical property and tissue mineral density differences among severely suppressed bone turnover (SSBT) patients, osteoporotic patients, and normal subjects10.1016/j.bone.2011.09.042 ↗
63. Age-related deterioration in trabecular bone mechanical properties at material level: nanoindentation study of the femoral neck in women by using AFM10.1016/j.exger.2011.11.011 ↗
64. Intrinsic material properties of trabecular bone by nanoindentation testing of biopsies taken from healthy women before and after menopause10.1007/s00223-012-9575-8 ↗
65. Anterior and posterior variations in mechanical properties of human vertebrae measured by nanoindentation10.1016/j.jbiomech.2012.11.008 ↗
66. Regional variation of bone tissue properties at the human mandibular condyle10.1016/j.bone.2015.04.024 ↗
67. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
68. The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties10.1016/S8756-3282(02)00782-2 ↗
69. Thresholding technique for accurate analysis of density and geometry in QCT, pQCT and muCT images
70. Micro-finite element simulation of trabecular-bone post-yield behaviour – effects of material model, element size and type10.1080/10255840701848756 ↗
71. The relationship between trabecular bone structure modeling methods and the elastic modulus as calculated by FEM10.1100/2012/827196 ↗
72. Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques10.1016/S0021-9290(98)00118-3 ↗
73. Convergence behavior of high-resolution finite element models of trabecular bone10.1115/1.2800865 ↗
74. Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study10.1016/j.jmbbm.2016.09.014 ↗
75. Effect of intraspecimen spatial variation in tissue mineral density on the apparent stiffness of trabecular bone10.1115/1.4029178 ↗
76. Biomechanical properties across trabeculae from the proximal femur of normal and ovariectomised sheep10.1016/j.jbiomech.2008.11.032 ↗
77. Biomechanical effects of intraspecimen variations in tissue modulus for trabecular bone10.1016/S0021-9290(01)00193-2 ↗
78. Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation10.1016/j.jbiomech.2003.10.002 ↗
79. Variations in mineralization affect the stress and strain distributions in cortical and trabecular bone10.1016/j.jbiomech.2006.06.004 ↗
80. Biomechanical effect of mineral heterogeneity in trabecular bone10.1016/j.jbiomech.2008.07.009 ↗
81. Biomechanical consequences of developmental changes in trabecular architecture and mineralization of the pig mandibular condyle10.1016/j.jbiomech.2006.07.030 ↗
82. Assessment of bone tissue mineralization by conventional x-ray microcomputed tomography: Comparison with synchrotron radiation microcomputed tomography and ash measurements10.1118/1.2924210 ↗
83. Mineral heterogeneity has a minor influence on the apparent elastic properties of human cancellous bone: a SRμCT-based finite element study10.1080/10255842.2011.581236 ↗
84. Characterization of the effects of X-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
85. Effects of high-dose gamma irradiation on tensile properties of human cortical bone: comparison of different radioprotective treatment methods10.1016/j.jmbbm.2016.04.017 ↗
86. Compressive mechanical properties of human cancellous bone after gamma irradiation10.2106/00004623-199274050-00014 ↗
87. Irradiation does not modify mechanical properties of cancellous bone under compression10.1007/s11999-011-2148-8 ↗
88. Effect of high-energy X-ray doses on bone elastic properties and residual strains10.1016/j.jmbbm.2011.05.035 ↗
89. Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts10.1007/s10561-008-9069-0 ↗
90. Human vertebral body apparent and hard tissue stiffness10.1016/S0021-9290(98)00110-9 ↗
91. Finite-element modeling of trabecular bone: comparison with mechanical testing and determination of tissue modulus10.1002/jor.1100160516 ↗
92. The role of an effective isotropic tissue modulus in the elastic properties of cancellous bone10.1016/S0021-9290(99)00045-7 ↗
93. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
94. A decreased subchondral trabecular bone tissue elastic modulus is associated with pre-arthritic cartilage damage10.1016/S0736-0266(01)00012-2 ↗
95. Prediction of mechanical properties of the cancellous bone of the mandibular condyle10.1177/154405910308201011 ↗
96. Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations10.1016/j.jbiomech.2008.02.032 ↗
97. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
98. Identification of couple-stress moduli of vertebral trabecular bone based on the 3D internal architectures10.1016/j.jmbbm.2015.06.036 ↗
99. 3D couple-stress moduli of porous polymeric biomaterials using µCT image stack and FE characterization10.1016/j.ijengsci.2015.11.006 ↗
100. A 3D elastic micropolar model of vertebral trabecular bone from lattice homogenization of the bone microstructure10.1007/s10237-013-0486-z ↗