Corrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation
Source abstract
Abstract
Cyclic stresses are often related to the premature mechanical failure of metallic biomaterials. The complex interaction between fatigue and corrosion in the physiological environment has been subject of many investigations. In this context, microstructure, heat treatments, plastic deformation, surface finishing and coatings have decisive influence on the mechanisms of fatigue crack nucleation and growth. Furthermore, wear is frequently present and contributes to the process. However, despite all the effort at elucidating the mechanisms that govern corrosion fatigue of biomedical alloys, failures continue to occur. This work reviews the literature on corrosion-fatigue-related phenomena of Ti alloys, surgical stainless steels, Co-Cr-Mo and Mg alloys. The aim was to discuss the correlation between structural and surface aspects of these materials and the onset of fatigue in the highly saline environment of the human body. By understanding such correlation, mitigation of corrosion fatigue failure may be achieved in a reliable scientific-based manner. Different mitigation methods are also reviewed and discussed throughout the text. It is intended that the information condensed in this article should be a valuable tool in the development of increasingly successful designs against the corrosion fatigue of metallic implants.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Magnesium Alloys: Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Fatigue characteristics of metallic biomaterials10.1016/j.ijfatigue.2006.09.021 ↗
2. Effect of surface treatments on fretting fatigue damage of biomedical titanium alloys10.1016/j.triboint.2006.02.064 ↗
3. Corrosion, fatigue and corrosion fatigue behavior of metal implant materials, especially titanium alloys10.1016/j.ijfatigue.2009.09.009 ↗
4. Unexpected finding of a fractured metal prosthetic femoral head in a nonmodular implant during revision total hip arthroplasty10.1016/j.arth.2009.02.022 ↗
5. Failure analysis of a Ti6Al4V cementless HIP prosthesis10.1016/j.engfailanal.2006.11.003 ↗
6. Stress-corrosion crack growth of Si–Na–K–Mg–Ca–P–O bioactive glasses in simulated human physiological environment10.1016/j.biomaterials.2007.08.005 ↗
7. Corrosion processes of physical vapor deposition-coated metallic implants10.1615/CritRevBiomedEng.v37.i6.10 ↗
8. Fatigue processes in metals – role of aqueous environments10.1016/0013-7944(90)90262-F ↗
9. Suresh · 2004
10. Failure analysis of a commercially pure titanium plate for osteosynthesis10.1016/S1350-6307(02)00067-5 ↗
11. Failure analysis of two Ti-alloy total hip arthroplasty femoral stems fractured in vivo10.1002/jbm.b.10003 ↗
12. Effect of precipitates on the corrosion fatigue crack initiation of ISSO 5832–9 stainless steel biomaterial10.1016/j.ijfatigue.2004.03.002 ↗
13. Fatigue of biomaterials: a review10.1016/S0142-1123(00)00052-9 ↗
14. A review of cyclic fatigue testing of nickel–titanium rotary instruments10.1016/j.joen.2009.06.015 ↗
15. Fatigue strength of 316L-type stainless steel in simulated body fluids10.1016/j.corsci.2011.03.004 ↗
16. Static, dynamics and fatigue behavior of newly designed stem shapes for hip prosthesis using finite element analysis10.1016/j.matdes.2006.02.015 ↗
17. Predicting the total fatigue life in metals10.1016/j.ijfatigue.2008.12.008 ↗
18. In-service fatigue failure of engineered products and structures – case study review10.1016/j.engfailanal.2008.08.008 ↗
19. Failure analysis of uncemented total hip stem due to microstructure and neck stress riser10.1016/j.engfailanal.2007.10.012 ↗
20. Small crack property of austenitic stainless steel with artificial corrosion pit in long life regime of fatigue10.1016/j.ijfatigue.2005.06.055 ↗
21. The effect manufacturing processes on the fatigue lifetime of aeronautical bolts10.1016/S1350-6307(00)00013-3 ↗
22. Fatigue crack initiation and propagation under cyclic contact loading10.1016/j.engfracmech.2009.02.005 ↗
23. Corrosion fatigue crack initiation behavior of stainless steels10.1016/j.proeng.2010.03.141 ↗
24. Investigation of the effect of grain clusters on fatigue crack initiation in polycrystals10.1016/j.ijfatigue.2010.04.003 ↗
25. Roles of microstructure in fatigue crack initiation10.1016/j.ijfatigue.2009.10.005 ↗
26. Nondestructive sizing and localization of internal microcracks in fatigue samples10.1016/j.ndteint.2007.02.001 ↗
27. Statistical pattern analysis of ultrasonic signals for fatigue damage detection in mechanical structures10.1016/j.ndteint.2008.06.001 ↗
28. Surface-related phenomena in low amplitude fatigue of fcc materials10.1016/0956-716X(92)90247-C ↗
29. Formation of slip steps and growth of extrusions within persistent slip bands in cyclically deformed polycrystals10.1016/j.msea.2007.06.044 ↗
30. The early stage of fatigue crack propagation10.1016/0013-7944(92)90059-N ↗
31. A physically based fatigue model prediction of crack initiation from persistent slip bands in polycrystals10.1016/j.actamat.2010.09.036 ↗
32. Introduction to the viewpoint set on: surface effects in cyclic deformation and fatigue10.1016/0956-716X(92)90246-B ↗
33. Fatigue crack nucleation at interface10.1016/j.msea.2003.12.094 ↗
34. The influence of a multilayered metallic coating on fatigue crack nucleation10.1016/S0142-1123(01)00153-0 ↗
35. Fatigue of structures and materials in the 20th century and the state of the art10.1016/S0142-1123(03)00051-3 ↗
36. Fatigue crack propagation
37. Fatigue failure of an orthopedic implant – a locking compression plate10.1016/j.engfailanal.2007.04.001 ↗
38. A unified interpretation of the power laws in fatigue and the analytical correlations between cyclic properties of engineering materials10.1016/j.ijfatigue.2009.04.014 ↗
39. Fatigue crack growth characteristics in cast Al–Si–Mg alloys Part II. Life predictions using fatigue crack growth data
40. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
41. Hip stem fatigue test prediction10.1016/j.ijfatigue.2008.10.005 ↗
42. Fatigue behavior of boron free and boron containing heat treated Ti–13Zr–13Nb alloy for biomedical applications10.1016/j.matchar.2010.10.004 ↗
43. A dimensional analysis interpretation to grain size and loading frequency dependencies of the Paris and Wöhler curves10.1016/j.ijfatigue.2010.10.001 ↗
44. Fatigue characteristics of bioactive glass–ceramic-coated Ti–29Nb–13Ta–4.6Zr for biomedical application10.1016/j.biomaterials.2003.09.108 ↗
45. Fatigue life determination of plasma nitride medical grade CoCrMo alloy10.1111/j.1460-2695.2010.01442.x ↗
46. On the fatigue behavior of an AISI 316L stainless steel coated with a PVD TiN deposit10.1016/j.surfcoat.2003.07.003 ↗
47. Corrosion fatigue behaviors of two biomedical Mg alloys – AZ91D and WE43 – in simulated body fluid10.1016/j.actbio.2010.07.026 ↗
48. A comparison of the fatigue behavior of cast Ti–7.5Mo with c.p. titanium, Ti–6Al–4V and Ti–13Nb–13Zr alloys10.1016/j.biomaterials.2004.09.007 ↗
49. Low cycle fatigue of superelastic NiTi wires10.1016/j.ijfatigue.2008.03.014 ↗
50. Deflection fatigue of cobalt–chromium, titanium, and gold alloy cast denture clasp10.1016/S0022-3913(05)80384-1 ↗
51. Total fatigue life prediction for Ti-alloys airframe structure based on durability and damage-tolerant design concept10.1016/j.matdes.2010.03.052 ↗
52. A rational analytic theory of fatigue
53. Propagation of short fatigue cracks10.1179/imr.1984.29.1.445 ↗
54. Initiation of fatigue cracks in commercial aluminium alloys and the subsequent propagation of very short cracks10.1016/0013-7944(75)90004-1 ↗
55. Prediction of the behavior of small fatigue cracks10.1016/j.msea.2006.09.084 ↗
56. Small fatigue crack growth in metallic materials: a model and its application to engineering alloys10.1016/j.actamat.2007.08.022 ↗
57. Similitude and the Paris crack growth law10.1016/j.ijfatigue.2008.01.016 ↗
58. Determination of cyclic strain-hardening behaviour produced during fatigue crack growth in cast Co–Cr–Mo alloy used for surgical implants10.1016/0921-5093(89)90427-9 ↗
59. Fatigue crack growth behavior of titanium foams for medical applications10.1016/j.msea.2010.11.024 ↗
60. Influence of microstructures on fatigue damage mechanisms in Ti-15–3 alloy10.1016/j.matdes.2010.08.051 ↗
61. A generalized Paris’ law for fatigue crack growth10.1016/j.jmps.2006.01.007 ↗
62. McEvily AJ, Wei RP. In: Corrosion fatigue – fatigue, mechanics & microstructure. NACE-2, 1972; p. 381–395.
63. Classification of environmentally assisted fatigue crack growth behavior10.1016/j.ijfatigue.2009.03.019 ↗
64. Extension of the unified approach to fatigue crack growth to environmental interactions10.1016/S0142-1123(01)00137-2 ↗
65. Third body effects and material fluxes in tribocorrosion systems involving a sliding contact10.1016/S0043-1648(03)00561-1 ↗
66. A tribological study of cobalt chromium molybdenum alloys used in metal-on-metal resurfacing hip arthroplasty10.1016/S0043-1648(03)00046-2 ↗
67. Effect of sliding wear on tribocorrosion behaviour of stainless steels in a Ringer’s solution10.1016/j.wear.2006.03.003 ↗
68. Wear and corrosion behaviour of Ti–13Nb–13Zr and Ti–6Al–4V alloys in simulated physiological solution10.1016/j.corsci.2010.11.014 ↗
69. Tribocorrosion behavior of β titanium alloys in physiological solutions containing synovial components10.1016/j.msec.2010.10.021 ↗
70. Implant retrieval studies of the wear and loosening of prosthetic joints: a review10.1016/S0043-1648(00)00370-7 ↗
71. Corrosion of metal orthopaedic implants10.2106/00004623-199802000-00015 ↗
72. Fretting corrosion behaviour of thermally oxidized CP-Ti in Ringer’s solution10.1016/j.corsci.2009.10.029 ↗
73. Friction in hip prostheses10.1016/S0142-9612(97)00034-3 ↗
74. Influence of plasma nitriding on fretting wear behaviour of Ti–6Al–4V10.1016/j.triboint.2009.05.020 ↗
75. Titanium alloys in total replacement – a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
76. Effect of low-temperature plasma carbonitriding on the fretting behaviour of 316LVM medical grade austenitic stainless steel10.1016/j.wear.2010.12.017 ↗
77. Surface property enhancement of Ni-free medical grade austenitic stainless steel by low-temperature plasma carburizing10.1016/j.surfcoat.2010.06.062 ↗
78. Synergistic effect of fretting wear and sliding wear of Co-alloy and Ti-alloy in Hanks’ solution10.1016/j.wear.2007.01.102 ↗
79. Electrochemical methods in tribocorrosion: a critical appraisal10.1016/S0013-4686(01)00679-X ↗
80. Effect of metallic nanoparticles on the biotribocorrosion behaviour of metal-on-metal hip prostheses10.1016/j.wear.2008.12.110 ↗
81. Conjoint corrosion and wear in titanium alloys10.1016/S0142-9612(98)00229-4 ↗
82. Fretting corrosion accelerates crevice corrosion of modular hip tapers10.1002/jab.770060104 ↗
83. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combination. The effect of crevice, stress, motion and alloy coupling10.1002/jbm.820271210 ↗
84. Fretting deterioration of orthopaedic implant materials: search for solutions10.1016/0267-6605(94)90049-3 ↗
85. Evaluation of the fretting corrosion behavior of the proximal pad taper of a modular hip design10.1016/S0043-1648(99)00110-6 ↗
86. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt.% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
87. Fretting-corrosion behavior of β titanium alloys in simulated synovial fluid10.1016/j.wear.2011.05.010 ↗
88. Triboelectrochemical behavior of a Si3N4–TiN ceramic composite and a titanium alloy commonly used in biomedical applications10.1016/j.wear.2008.07.005 ↗
89. Do oral biofilms influence the wear and corrosion behavior of titanium?10.1080/08927011003767985 ↗
90. Influence of electrochemical potential on the tribocorrosion behaviour of high carbon CoCrMo biomedical alloy in simulated body fluids by electrochemical impedance spectroscopy10.1016/j.electacta.2010.04.093 ↗
91. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
92. Micro-abrasion–corrosion of a CoCrMo alloy in simulated artificial hip joint environments10.1016/j.wear.2005.02.045 ↗
93. Biotribocorrosion of CoCrMo orthopaedic implant materials – assessing the formation and effect of the biofilm10.1016/j.triboint.2007.02.019 ↗
94. Tribo-corrosion properties of cobalt-based medical implant alloys in simulated biological environments10.1016/j.wear.2007.01.114 ↗
95. Tribocorrosion in implants – assessing high carbon and low carbon Co–Cr–Mo alloys by in situ electrochemical measurements10.1016/j.triboint.2006.01.016 ↗
96. Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys
97. Effect of surface chemistry on the mechanical response of metals in sliding tribocorrosion systems10.1016/j.wear.2007.01.066 ↗
98. Micro-abrasion-corrosion of cast CoCrMo – effects of micron and sub-micron sized abrasives10.1016/j.wear.2009.01.011 ↗
99. Fretting fatigue crack analysis in Ti–6Al–4V10.1016/j.ijfatigue.2005.07.008 ↗
100. Chandra A, Ryu JJ, Karra P, Shrotriya P, Tvergaard V, Gaisser M, Weik T. Life expectancy of modular Ti6Al4V hip implants: influence of stress and environment. J Mech Behav Biomed Mater 2011; doi: 10.1016/j.jmbbm.2011.06.018.10.1016/j.jmbbm.2011.06.018 ↗