journal article·2012-04

Prediction of permeability of regular scaffolds for skeletal tissue engineering: A combined computational and experimental study

S. Truscello, G. Kerckhofs, S. Van Bael, G. Pyka, J. Schrooten, H. Van Oosterwyck

Acta Biomaterialia· Volume 8· Issue 4
Publisher page

Abstract

Scaffold permeability is a key parameter combining geometrical features such as pore shape, size and interconnectivity, porosity and specific surface area. It can influence the success of bone tissue engineering scaffolds, by affecting oxygen and nutrient transport, cell seeding efficiency, in vitro three-dimensional (3D) cell culture and, ultimately, the amount of bone formation. An accurate and efficient prediction of scaffold permeability would be highly useful as part of a scaffold design process. The aim of this study was (i) to determine the accuracy of computational fluid dynamics (CFD) models for prediction of the permeability coefficient of three different regular Ti6Al4V scaffolds (each having a different porosity) by comparison with experimentally measured values and (ii) to verify the validity of the semi-empirical Kozeny equation to calculate the permeability analytically. To do so, five CFD geometrical models per scaffold porosity were built, based on different geometrical inputs: either based on the scaffold's computer-aided design (CAD) or derived from 3D microfocus X-ray computed tomography (micro-CT) data of the additive manufactured (AM) scaffolds. For the latter the influence of the spatial image resolution and the image analysis algorithm used to determine the scaffold's architectural features on the predicted permeability was analysed. CFD models based on high-resolution micro-CT images could predict the permeability coefficients of the studied scaffolds: depending on scaffold porosity and image analysis algorithm, relative differences between measured and predicted permeability values were between 2% and 27%. Finally, the analytical Kozeny equation was found to be valid. A linear correlation between the ratio Φ(3)/S(s)(2) and the permeability coefficient k was found for the predicted (by means of CFD) as well as measured values (relative difference of 16.4% between respective Kozeny coefficients), thus resulting in accurate and efficient calculation of the permeability of regular AM scaffolds.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. A tissue engineering approach to bone repair in large animal models and in clinical practice10.1016/j.biomaterials.2007.06.023 ↗
2. Bone tissue engineering: a review in bone biomimetics and drug delivery strategies10.1002/btpr.246 ↗
3. State of the art and future directions of scaffold-based bone engineering from a biomaterials perspective10.1002/term.24 ↗
4. Microcellular polyHIPE polymer supports osteoblast growth and bone formation in vitro10.1016/j.biomaterials.2003.10.086 ↗
5. Osteogenesis in marrow-derived mesenchymal cell porous ceramic composites transplanted subcutaneously: effect of fibronectin and laminin on cell retention and rate of osteogenic expression10.1177/096368979200100106 ↗
6. The effect of pore size on cell adhesion in collagen-GAG scaffolds10.1016/j.biomaterials.2004.02.052 ↗
7. Macroporous biphasic calcium phosphate scaffold with high permeability/porosity ratio10.1089/107632703322066714 ↗
8. Tissue engineered bone: measurement of nutrient transport in three-dimensional matrices10.1002/jbm.a.10111 ↗
9. Controlled cell-seeding methodologies: a first step toward clinically relevant bone tissue engineering strategies10.1089/ten.tec.2010.0069 ↗
10. Mechanical, permeability, and degradation properties of 3D designed poly(1, 8 octanediol-co-citrate) scaffolds for soft tissue engineering10.1002/jbm.b.31568 ↗
11. Fluid conductance of cancellous bone graft as a predictor for graft–host interface healing10.1016/0021-9290(95)00010-0 ↗
12. Characterization of the structure and permeability of titanium foams for spinal fusion devices10.1016/j.actbio.2008.06.014 ↗
13. Darcy · 1856
14. Arora · 2009
15. Ceramic TiO2-foams: characterisation of a potential scaffold
16. Direct perfusion measurements of cancellous bone anisotropic permeability10.1016/S0021-9290(01)00082-3 ↗
17. Three-dimensional poly(1, 8-octanediol–co-citrate) scaffold pore shape and permeability effects on sub-cutaneous in vivo chondrogenesis using primary chondrocytes10.1016/j.actbio.2010.08.027 ↗
18. Prediction of ceramic foams permeability using Ergun’s equation10.1590/S1516-14391999000400008 ↗
19. On scaffold designing for bone regeneration: a computational multiscale approach10.1016/j.actbio.2008.06.021 ↗
20. Computational design of tissue engineering scaffolds10.1016/j.cma.2006.09.023 ↗
21. Multiscale modeling of bone tissue with surface and permeability control10.1016/j.jbiomech.2010.10.007 ↗
22. Carman · 1956
23. Analysis of flow in fractal porous media10.1115/1.2955849 ↗
24. Taylor · 1948
25. Fabrication and characterization of poly(propylene fumarate) scaffolds with controlled pore structures using 3-dimensional printing and injection molding10.1089/ten.2006.12.2801 ↗
26. Micro-CT-based screening of biomechanical and structural properties of bone tissue engineering scaffolds10.1007/s11517-006-0071-z ↗
27. Bimodular flow characterisation in tissue engineering scaffolds using computational fluid dynamics and particle imaging velocimetry10.1089/ten.tec.2010.0107 ↗
28. Microarchitectural and mechanical characterization of oriented porous polymer scaffolds10.1016/S0142-9612(02)00361-7 ↗
29. A comparison of micro CT with other techniques used in the characterization of scaffolds10.1016/j.biomaterials.2005.08.035 ↗
30. Non-destructive quantitative 3D analysis for the optimisation of tissue scaffolds10.1016/j.biomaterials.2006.11.014 ↗
31. Micro-CTbased improvement of geometrical and mechanical controllability of selective laser melted Ti6Al4V porous structures10.1016/j.msea.2011.06.045 ↗
32. Validation of X-ray microfocus computed tomography as an imaging tool for porous structures10.1063/1.2838584 ↗
33. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
34. Accuracy of cancellous bone volume fraction measured by micro-ct scanning10.1016/S0021-9290(98)00176-6 ↗
35. Sahimi · 1995
36. Resolution dependency of microstructural properties of cancellous bone based on threedimensional mu-tomography10.3233/THC-1996-4112 ↗
37. Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7 and 2 micron level10.3233/THC-1998-65-611 ↗
38. Comparison of Microcomputed Tomographic and Microradiographic Measurements of Cortical Bone Porosity10.1007/s00223-003-0071-z ↗
39. Truscello S, Schrooten J, Van Oosterwyck H. A computational tool for the upscaling of regular scaffolds during in vitro perfusion culture. Tissue Eng Part C Method 2011;17:619–30.10.1089/ten.tec.2010.0647 ↗
40. Modeling fluid flow through irregular scaffolds for perfusion bioreactors10.1002/bit.22277 ↗
41. Dependence of intertrabecular permeability on flow direction and anatomic site10.1114/1.195 ↗