journal article·2010-01

Conducting polymers on hydrogel-coated neural electrode provide sensitive neural recordings in auditory cortex

Dong-Hwan Kim, James A. Wiler, David J. Anderson, Daryl R. Kipke, David C. Martin

Acta Biomaterialia· Volume 6· Issue 1
Publisher page

Abstract

Recently, a significant amount of effort has been dedicated to understanding factors that influence the functionality of bio-electronic sensors and to development of novel coating technologies for modifying biosensor surfaces. Due to its well-known biocompatibility, alginate hydrogel (HG) has been used as a coating material on neural electrodes for promoting intimate cellular integration, providing a scaffold for local drug delivery, and creating a mechanical buffer between hard electrodes and the soft tissues of the central nervous system. However, neural signal recordings using HG-coated electrodes in animal models are still poorly evaluated. Here, we investigated the effect of the proximity of source neurons around the electrode sites using HG coatings with various thicknesses deposited on microfabricated electrodes, implanted in auditory cortex of guinea pigs. We also evaluated the role of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) in improving the recording functionality of the HG-coated neural electrodes. A significant loss in recording functionality was observed with thicker HG coatings, as determined by the number of clearly detectable units (30% with 80 microm thick coatings) and average signal-to-noise ratios (3.91 with 80 microm thick coatings). However, deposition of the conducting polymer PEDOT on the electrode sites restored the lost functionality of the electrodes caused by the HG coatings (30 microm). These conducting polymer/HG coatings have the potential to improve long-term performance of the neural electrodes not only by improving the electrode biocompatibility but also by facilitating more efficient signal transmission.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Conducting polymers and applications · EEG and Brain-Computer Interfaces

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Hearing by cochlear nucleus stimulation in humans
2. Translational principles of deep brain stimulation10.1038/nrn2196 ↗
3. Cortical neural prosthetics10.1146/annurev.neuro.27.070203.144233 ↗
4. Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex10.1109/TBME.2004.826680 ↗
5. Brain responses to micro-machined silicon devices10.1016/S0006-8993(03)03023-3 ↗
6. Controlling cellular reactive responses around neural prosthetic devices using peripheral and local intervention strategies10.1109/TNSRE.2003.814800 ↗
7. Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices10.1002/jbm.a.30124 ↗
8. A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex10.1088/1741-2560/2/4/006 ↗
9. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays10.1016/j.expneurol.2005.04.020 ↗
10. Flexible polyimide-based intracortical electrode arrays with bioactive capability10.1109/10.914800 ↗
11. Multifunctional nanobiomaterials for neural interfaces10.1002/adfm.200801473 ↗
12. In vivo studies of polypyrrole/peptide coated neural probes10.1016/S0142-9612(02)00415-5 ↗
13. Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery10.1016/j.biomaterials.2005.12.021 ↗
14. Effect of immobilized nerve growth factor on conductive polymers: electrical properties and cellular response10.1002/adfm.200500594 ↗
15. Release of nerve growth factor from HEMA hydrogel-coated substrates and its effect on the differentiation of neural cells10.1021/bm801101e ↗
16. Composition and crystallization of hydroxyapatite coating layer formed by electron beam deposition10.1111/j.1151-2916.2003.tb03301.x ↗
17. Neurotrophin-eluting hydrogel coatings for neural stimulating electrodes10.1002/jbm.b.30696 ↗
18. Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes10.1016/j.brainres.2007.02.024 ↗
19. Controlling mechanical and swelling properties of alginate hydrogels independently by cross-linker type and cross-linking density10.1021/ma9921347 ↗
20. Miller K, Chinzei K. Modeling of brain tissue mechanical properties: bi-phasic versus single-phase approach. Comput Methods Biomech Biomed Eng (Proceedings of the Third International Symposium) 1997.
21. Intracellular features predicted by extracellular recordings in the hippocampus in vivo10.1152/jn.2000.84.1.390 ↗
22. Ionically crosslinked alginate hydrogels as scaffolds for tissue engineering: Part 1. Structure, gelation rate and mechanical properties10.1016/S0142-9612(00)00201-5 ↗
23. Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex10.1016/S1385-299X(99)00034-3 ↗
24. Abidian MR, Kim DH, Martin DC. Conducting-polymer nanotubes for controlled drug release. Adv Mater 2006;18:405–409.10.1002/adma.200501726 ↗
25. Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays10.1016/S0925-4005(02)00448-3 ↗
26. Microporous conducting polymers on neural microelectrode arrays. I. Electrochemical deposition10.1016/j.snb.2004.02.056 ↗
27. Microporous conducting polymers on neural microelectrode arrays II. Physical characterization10.1016/j.sna.2004.02.029 ↗