Effect of cleaning and sterilization on titanium implant surface properties and cellular response
Source abstract
Abstract
Titanium (Ti) has been widely used as an implant material due to the excellent biocompatibility and corrosion resistance of its oxide surface. Biomaterials must be sterile before implantation, but the effects of sterilization on their surface properties have been less well studied. The effects of cleaning and sterilization on surface characteristics were bio-determined using contaminated and pure Ti substrata first manufactured to present two different surface structures: pretreated titanium (PT, Ra=0.4 μm) (i.e. surfaces that were not modified by sandblasting and/or acid etching); (SLA, Ra=3.4 μm). Previously cultured cells and associated extracellular matrix were removed from all bio-contaminated specimens by cleaning in a sonicator bath with a sequential acetone-isopropanol-ethanol-distilled water protocol. Cleaned specimens were sterilized with autoclave, gamma irradiation, oxygen plasma, or ultraviolet light. X-ray photoelectron spectroscopy (XPS), contact angle measurements, profilometry, and scanning electron microscopy were used to examine surface chemical components, hydrophilicity, roughness, and morphology, respectively. Small organic molecules present on contaminated Ti surfaces were removed with cleaning. XPS analysis confirmed that surface chemistry was altered by both cleaning and sterilization. Cleaning and sterilization affected hydrophobicity and roughness. These modified surface properties affected osteogenic differentiation of human MG63 osteoblast-like cells. Specifically, autoclaved SLA surfaces lost the characteristic increase in osteoblast differentiation seen on starting SLA surfaces, which was correlated with altered surface wettability and roughness. These data indicated that recleaned and resterilized Ti implant surfaces cannot be considered the same as the first surfaces in terms of surface properties and cell responses. Therefore, the reuse of Ti implants after resterilization may not result in the same tissue responses as found with never-before-implanted specimens.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Biology of implant osseointegration
2. Potential of chemically modified hydrophilic surface characteristics to support tissue integration of titanium dental implants10.1002/jbm.b.31233 ↗
3. Underlying mechanisms at the bone–biomaterial interface10.1002/jcb.240560310 ↗
4. Biomaterial and implant surface – on the role of cleanliness, contamination, and preparation procedures10.1002/jbm.820221307 ↗
5. Proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63) cultured on previously used titanium surfaces10.1034/j.1600-0501.1996.070104.x ↗
6. Effect of passivation and dry heat-sterilization on surface energy and topography of unalloyed titanium implants10.1016/S0927-7757(97)00237-9 ↗
7. Surface-analysis of titanium after sterilization – role in implant–tissue interface and bioadhesion10.1016/0022-3913(87)90279-4 ↗
8. Characterization of Bacillus subtilis spore inactivation in low-pressure, low-temperature gas plasma sterilization processes10.1111/j.1365-2672.2009.04453.x ↗
9. Low pressure plasma discharges for the sterilization and decontamination of surfaces10.1088/1367-2630/11/11/115017 ↗
10. Plasma sterilization using the RF glow discharge10.1016/j.apsusc.2009.03.026 ↗
11. Dynamic sterilization of titanium implants with ultraviolet light
12. Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem10.1016/0142-9612(95)00349-5 ↗
13. Accelerated oxide growth on titanium implants during autoclaving caused by fluorine contamination10.1016/0142-9612(85)90033-X ↗
14. Toxic effects of ethylene oxide residues on in vitro production of bovine embryos10.1016/0093-691X(95)92391-L ↗
15. Effects of gamma-irradiation, storage and hydration on osteoinductivity of DBM and DBM/AM composite10.1002/jbm.a.31790 ↗
16. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids10.1016/S0142-9612(03)00372-7 ↗
17. Effect of several sterilisation techniques on homogeneous self assembled monolayers10.1016/j.colsurfb.2005.05.009 ↗
18. Investigation on surface properties of TiO2 films modified by DC glow discharge plasma10.1016/j.cap.2008.11.005 ↗
19. Role of material surfaces in regulating bone and cartilage cell response10.1016/0142-9612(96)85758-9 ↗
20. Osteoblasts generate an osteogenic microenvironment when grown on surfaces with rough microtopographies10.22203/eCM.v006a03 ↗
21. Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells10.1002/(SICI)1097-4636(199609)32:1<55::AID-JBM7>3.0.CO;2-O ↗
22. Direct and indirect effects of microstructured titanium substrates on the induction of mesenchymal stem cell differentiation towards the osteoblast lineage10.1016/j.biomaterials.2009.12.029 ↗
23. The influence of blasting and sterilization on static and time-related wettability and surface-energy properties of titanium surfaces10.1016/j.surfcoat.2007.12.021 ↗
24. Surface spectroscopic characterization of titanium implant materials10.1016/0169-4332(90)90100-E ↗
25. Surface analysis of failed oval titanium implants10.1002/(SICI)1097-4636(1999)48:4<559::AID-JBM23>3.0.CO;2-M ↗
26. Requirement for both micron- and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topography10.1016/j.biomaterials.2007.02.024 ↗
27. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces10.1002/jbm.a.30518 ↗
28. A multitechnique study of the spontaneous oxidation of n-hexane plasma polymers10.1002/pola.1994.080320801 ↗
29. High surface energy enhances cell response to titanium substrate microstructure10.1002/jbm.a.30320 ↗
30. Surface spectroscopic characterization of titanium implant materials10.1016/0368-2048(95)02530-8 ↗
31. Degradative effects of conventional steam sterilization on biomaterial surfaces10.1016/0142-9612(82)90027-8 ↗
32. Dental implant materials. I. Some effects of preparative procedures on surface topography10.1002/jbm.820250902 ↗
33. Dental implant materials. 2. Preparative procedures and surface spectroscopic studies10.1002/jbm.820250903 ↗
34. Ultraviolet treatment overcomes time-related degrading bioactivity of titanium10.1089/ten.tea.2008.0568 ↗
35. Identification of oxide layers of commercially pure titanium in response to cleaning procedures
36. Characterization of sterilized cp titanium implant surfaces
37. Bone cell expression on titanium surfaces is altered by sterilization treatments10.1177/00220345940730050801 ↗
38. Surface energy and surface roughness changes produced by irradiating polymers with ultraviolet-ozone