journal article·2007-05

Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release

Liliane S. Morais, Glaucio G. Serra, Carlos A. Muller, Leonardo R. Andrade, Elisabete F.A. Palermo, Carlos N. Elias, Marc Meyers

Acta Biomaterialia· Volume 3· Issue 3
Publisher page

Abstract

Removable osseointegrated titanium mini-implants were successfully used as anchorage devices in orthodontics. The early load is necessary to simplify the mini-implant methodology, but can lead to failure during osseointegration. The Ti-6Al-4V alloy was used instead of commercially pure Ti due to its superior strength. However, the corrosion resistance is low, allowing for metal ion release. The purpose of this work was to analyze the immediately loaded mini-implant fixation and to gauge the vanadium ion release during the healing process. Titanium alloy mini-implants were inserted in the tibiae of rabbits. After 1, 4 and 12 weeks, they were submitted to removal torque testing. There was no increase in the removal torque value between 1 and 4 weeks of healing, regardless of the load. Nevertheless, after 12 weeks, a significant improvement was observed in both groups, with the highest removal torque value for the unloaded group. The kidney, liver and lung were also extracted and analyzed by atomic absorption spectrometry. In comparison with the control values, the content of vanadium increased slightly after 1week, significantly increased after 4 weeks and decreased slightly after 12 weeks, without reaching the 1 week values. A stress analysis was carried out which enables both the prediction of the torque at which commercially pure (CP) Ti and Ti-6Al-4V deform plastically and the shear strength of the interface. This analysis reveals that the removal torques for CP Ti dangerously approach the yield stress. The results of this rabbit model study indicate that titanium alloy mini-implants can be loaded immediately with no compromise in their stability. The detected concentration of vanadium did not reach toxic levels in the animal model.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthodontics and Dentofacial Orthopedics · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Graber · 1996
2. Orthodontic anchorage with specific fixtures: related study analysis10.1067/mod.2002.124870 ↗
3. Rigid endosseous implants for orthodontic and orthopedic anchorage
4. A clinical and histological evaluation of titanium mini-implants as anchor for orthodontic intrusion in the beagle dog10.1067/mod.2001.114300 ↗
5. Mini-implant for orthodontic anchorage
6. Intrusion of posterior teeth using mini-screw implants10.1016/S0889-5406(03)00047-7 ↗
7. Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site
8. Rigid implant anchorage to close a mandibular first molar extraction site
9. Miniscrews as orthodontic anchorage: A preliminary report
10. Zigoma ligature: an alternative form of maxillary anchorage
11. Corrosion behavior of commercially pure titanium shot blasted with different materials and sizes of shot particles for dental implant applications10.1016/S0142-9612(02)00314-9 ↗
12. Application of bulk nanostructured materials in medicine10.1016/j.cap.2005.07.053 ↗
13. Metal ion release from metal implants10.1016/j.msec.2004.08.018 ↗
14. Comparison of metal concentrations in rat tibia tissues with various metallic implants10.1016/j.biomaterials.2004.01.064 ↗
15. Food and Nutrition Board. Dietary reference intakes: elements. 2001. Available from: http://www.iom.edu/Object.File/Master/7/294/0.pdf.
16. In vitro kinetic evaluation of titanium alloy biodegradation10.1034/j.1600-0765.2001.360501.x ↗
17. The efficacy of deferiprone on tissues aluminum removal and copper, zinc, manganese level in rabbits10.1016/j.jinorgbio.2005.06.002 ↗
18. Pharmacokinetics of vanadium in humans after intravenous administration of a vanadium containing albumin solution10.1046/j.1365-2125.2003.01711.x ↗
19. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage10.1016/S0889-5406(03)00565-1 ↗
20. Group distal movement of teeth using microscrew implant anchorage
21. Load-related implant reaction of mini-implants used for orthodontic anchorage10.1111/j.1600-0501.2005.01149.x ↗
22. Dental implants for orthodontic anchorage10.1016/j.ajodo.2004.02.019 ↗
23. Osseous adaptation to continuous loading of rigid endosseous implants10.1016/0002-9416(84)90301-4 ↗
24. Mechanism of osseointegration: characterization of supporting bone with indentation testing and backscattered imaging10.1053/j.sodo.2004.01.004 ↗
25. Use of miniscrews for intermaxillary fixation of lingual-orthodontic surgical patients
26. Pull-out strength of monocortical screws placed in maxillae and mandibles of dogs10.1016/j.ajodo.2003.12.023 ↗
27. Timing of loading and effect of micromotion on bone-implant interface: review of experimental literature10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K ↗
28. Davis · 2000
29. The use of small titanium screws for orthodontic anchorage10.1177/154405910308200510 ↗
30. Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: early continuous distalizing forces10.1093/ejo/21.3.223 ↗
31. Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications10.1034/j.1600-0501.2001.012004358.x ↗
32. Treatment of open bite with microscrew implant anchorage10.1016/j.ajodo.2003.07.019 ↗
33. Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design10.1016/j.ajodo.2004.02.023 ↗
34. Peri-implant bone response to orthodontic loading: Part 2. Implant surface geometry and its effect on regional bone remodeling10.1016/j.ajodo.2004.02.024 ↗
35. Popov · 1990
36. Meyers · 1999
37. Changes in canine cortical and cancellous bone mechanical properties following immobilization and remobilization with exercise10.1016/S8756-3282(97)00167-1 ↗
38. The biological response to titanium and titanium–aluminium–vanadium alloy particles10.1016/0142-9612(86)90085-2 ↗
39. Research progress on laser surface modification of titanium alloys10.1016/j.apsusc.2004.08.011 ↗
40. Calcium phosphate naturally formed on titanium in electrolyte solution10.1016/0142-9612(91)90028-9 ↗
41. The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti–6Al–4V alloys10.1016/S0142-9612(03)00606-9 ↗
42. ASTM-F86 passivation increases trace element release from Ti–6Al–4V into culture medium10.1007/BF00058985 ↗
43. Metal release from dental biomaterials10.1016/0142-9612(86)90097-9 ↗
44. Titanium orthodontic brackets: structure, composition, hardness and ionic release10.1016/j.dental.2004.02.008 ↗