journal article·2018-08-13Open access

Fire Safety of Mass timber Buildings with CLT in USA

David Barber

Wood and Fiber Science· Volume 50· Issue Special

Abstract

Multistory buildings using mass timber and cross-laminated timber (CLT) as the primary structural elements are being planned and constructed globally, with interest starting to gather momentum in the United States. Model building codes in the United States limit timber construction to a building height of 85 ft (25.9 m) because of concerns over fire safety and structural performance. Up to 85 ft, the mass timber can be exposed. Architects and developers in the United States are pushing boundaries, requesting mass timber structures are constructed as high-rises and that load-bearing mass timber such as CLT be exposed and not fully protected. This provides an opportunity for the application of recent fire research and fire testing on exposed CLT to be applied, and existing methods of analyzing the impact of fire on engineered timber structures to be developed further. Fire testing has shown that exposing large areas of CLT significantly impacts the heat release rate and fire duration. This article provides an overview of the code requirements for timber construction in the United States, provides methods for building approval for a high-rise timber structure, and summarizes recent CLT compartment fire testing that is informing the fire engineering process. Methods for solutions are also discussed.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on ecosystems · Fire dynamics and safety research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Aguanno, M., 2013, "Fire Resistance Tests on Cross-Laminated Timber Floor Panels: An Experimental and Numerical Analysis". Department of Civil and Environmental Engineering, Carleton University, Ottawa, Canada American Society for Testing and Materials, 2015, "ASTM E84: Standard Test Method for Surface Burning Characteristics of Building Materials"
2. American Society for Testing and Materials, 2016, "ASTM E119: Standard Test Methods for Fire Tests of Building Construction and Materials"
3. American Wood Council, 2012, "Code Conforming Wood Design", Leesburg, Virginia American Wood Council, 2015, "National Design Specification for Wood Construction", Leesburg, Virginia American Wood Council, 2015a, "Calculating the Fire Resistance of Exposed Wood Members, Technical Report No. 10", Leesburg, Virginia
4. Babrauskas, V., 2004, "Wood Char Depth: Interpretation in Fire Investigations" Presented at International Symposium on Fire Investigation, Fire Service College, Moreton-in-Marsh, United Kingdom
5. Barber D, Crielaard R, Li X (2016) Towards fire safe design of exposed timber in tall timber buildings. In Proc. World Conference of Timber Engineering, August 22-25, 2016, Vienna, Austria.
6. British Standards (2013) Eurocode 1: Actions on structures part 1-2: General actions—Actions on structures exposed to fire. BS EN 1991-1-2:2002, incorporating amendments to 2013.
7. Buchanan A (2001) Structural design for fire safety. John Wiley and Sons.
8. City of New York (2014) 2014 construction codes. http://www1.nyc.gov/site/buildings/codes/2014-constructioncodes.page.
9. Craft ST, et al (2011) Investigation of the behaviour of CLT panels exposed to fire. In Proc. 12th International Conference Fire and Materials.
10. Crielaard R (2015) Self-extinguishment of cross-laminated timber. Master's Thesis report, Faculty of Civil Engineering and Geosciences, Delft University of Technology.
11. Department of Commerce (1942) Building materials and structures, report BMS92, fire resistance classification of structures. National Bureau of Standards, report of sub-committee on fire resistance classifications of central housing committee on research, design and construction.
12. Drysdale D (2011) An introduction to fire dynamics, 3rd Ed. Wiley.10.1002/9781119975465 ↗
13. Emberley R, Gorska C, Bolanosa A, Lucherinia A, Solartea A, Soriguera D, Gutierrez M, Humphreys K, Hidalgoa J, Maluka C, Law A, Torero J (2017) Description of small and large-scale cross laminated timber fire tests. Fire Saf J 91:327-335.10.1016/j.firesaf.2017.03.024 ↗
14. Frangi A, et al (2008) Fire behaviour of cross-laminated solid timber panels. Institute of Structural Engineering, ETH Zurich, Zurich, Switzerland.
15. Hadden R, Bartlett A, Hidalgo J, Santamaria S, Wiesner F, Bisby L, Deeny S, Lane B (2017) Effects of exposed engineered timber on compartment fire dynamics. In Proc. 12th International Association of Fire Safety Science Symposium, June 10-16, 2017, Lund, Sweden.
16. Hox K, et al (2015) "Branntest av massivtre" SP fire research, report A15101 (in Norwegian, translated by Arup). International Code Council (ICC) (2015) International building code.
17. Kimball A, Hoehler M, Su J (2017) Fire safety challenges of tall wood—Report on cross laminated timber (CLT) compartment fire tests. In NFPA Conference and Expo, June 4-7, 2017, Boston, MA.
18. Karacabeyli E, Douglas B (2013) CLT handbook, US edition. FPInnovations SP529-E.
19. Klippel M, Schmid J, Frangi A (2016) Fire design of CLT, paper submitted for joint event of COST actions FP1402 and FP1404. KTH Stockholm.
20. McGregor C (2013)Contribution of cross laminated timber panels to room fires. Thesis, Department of Civil and Environmental Engineering, Carleton University, Ottawa, ON, Canada.
21. Medina A (2014) Fire resistance of partially protected crosslaminated timber rooms. Thesis, Faculty of Graduate and Postdoctoral Affairs, Civil Engineering, Carleton University Ottawa, ON, Canada.
22. National Fire Protection Association (NFPA) (2015) "Life safety code" NFPA 101.
23. Reska P (2008) In-depth temperature profiles in pyrolyzing wood. Thesis submitted for the degree of Doctor of Philosophy, University of Edinburgh.
24. Underwriters Laboratories (2014) UL 263—Standard for fire tests of building construction and materials.
25. United States Department of Agriculture (USDA) (2015) Tall wood building competition. https://www.rethinkwood.com/tall-wood-mass-timber/tall-woodcompetition.
26. Wilinder P (2010) Fire resistance in cross laminated timber. Master's thesis, Jonkoping University, Jonkoping, Sweden.
27. White R (2016) Analytical methods for determining fire resistance of timber members. In SFPE handbook of fire protection engineering, 5th Ed.10.1007/978-1-4939-2565-0_55 ↗