Analysis of Adhesive Penetration into Wood using Nano-X-ray Computed Tomography
Source abstract
Abstract
This study focused on the penetration of adhesive into cell lumens and cell walls. Douglas-fir samples containing an iodinated phenol-formaldehyde adhesive were analyzed using nano-X-ray computed tomography (XCT), X-ray fluorescence microscopy, and energy-dispersive X-ray spectroscopy to observe adhesive penetration in cell walls. A gradient of penetration was observed within the cell wall structure. In addition, these nano-XCT datasets were indexed to previous micro-XCT datasets, which gave the ability to link the nanoscale cell wall penetration to microscale penetration in to the porous network of cell lumens.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced X-ray Imaging Techniques · Wood Treatment and Properties · Cultural Heritage Materials Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Bin B, Rukai Z, Songtao W, Wenjing Y, Gelb J, Gu A, Xiangxiang Z, Ling S (2013) Multi-scale method of nano(micro)-CT study on microscopic pore structure of tight sandstone of Yanchang Formation, Ordos Basin. Petrol Explor Dev 40(3):354-358.10.1016/S1876-3804(13)60042-7 ↗
2. Cetinbas FC, Ahluwalia RK, Kariuki N, De Andrade V, Fongalland D, Smith L, Sharman J, Ferreira P, Rasouli S, Myers DJ (2017) Hybrid approach combining multiple characterization techniques and simulations for microstructural analysis of proton exchange membrane fuel cell electrodes. J Power Sources 344:62-73.10.1016/j.jpowsour.2017.01.104 ↗
3. De Andrade V, Deriy A, Wojcik MJ, Gursoy D, Shu D, ¨ Fezzaa K, De Carlo F (2016) Nanoscale 3D imaging at the advanced photon source. SPIE Newsroom May 12, 2016. doi: 10.1117/2.1201604.006461.10.1117/2.1201604.006461 ↗
4. De Carlo F, Gursoy D, Marone F, Rivers M, Parkinson YD, Khan F, Schwarz N, Vine DJ, Vogt S, Gleber SC, Narayanan S, Newville M, Lanzirotti T, Sun Y, Hong YP, Jacobsen C (2014) Scientific data exchange: A schema for hdf5-based storage of raw and analyzed data. J Synchrotron Radiat 21(6): 1224-1230.10.1107/S160057751401604X ↗
5. Evans PD, Morrison O, Senden TJ, Vollmer S, Roberts RJ, Limaye A, Arns CH, Averdunk H, Lowe A, Knackstedt MA (2010) Visualization and numerical analysis of adhesive distribution in particleboard using X-ray microcomputed tomography. Int J Adhes Adhes 30:754-762.10.1016/j.ijadhadh.2010.08.001 ↗
6. Gindl W (2001) SEM and UV-microscopic investigation of glue lines in Parallam PSL. Holz Roh Werkst 59:211-21410.1007/s001070100194 ↗
7. Gindl W, Dessipri E, Wimmer R (2002) Using UV-microscopy to study diffusion of melamine-urea-formaldehyde resin in cell walls of spruce wood. Holzforschung 56:103-107.10.1515/HF.2002.017 ↗
8. Gindl W, Schoberl T, Jeronimidis G (2004) The interphase in phenol-formaldehyde and polymeric methylene di-phenyl-diisocyanate glue lines in wood. Int J Adhes Adhes 24:279-286.10.1016/j.ijadhadh.2003.10.002 ↗
9. Gursoy D, De Carlo F, Xiao X, Jacobsen C (2014) TomoPy: ¨ A framework for the analysis of synchrotron tomographic data. J Synchrotron Radiat 21:1188-1193.10.1107/S1600577514013939 ↗
10. Hass P, Wittel FK, Mendoza M, Herrmann HJ, Niemz P (2012) Adhesive penetration in beech wood: experiments. Wood Sci Technol 46:243-25610.1007/s00226-011-0410-6 ↗
11. Jakes J, Hunt C, Yelle D, Lorenz L, Hirth K, Gleber S-C, Vogt S, Grigsby W, Frihart C (2015) Synchrotron-based X-ray fluorescence microscopy in conjunction with nanoindentation to study molecular-scale interactions of phenol-formaldehyde in wood cell walls. ACS Appl Mater Interfaces 7:6584-6589.10.1021/am5087598 ↗
12. Jeremic D, Cooper P, Brodersen P (2007) Penetration of poly (ethylene glycol) into wood cell walls of red pine. Holzforschung 61:272-278.10.1515/HF.2007.068 ↗
13. Kamke FA, Nairn JA, Muszynski L, Paris J, Schwarzkopf M, Xiao X (2014) Methodology for micro-mechanical analysis of wood-adhesive bonds using XCT and numerical modeling. Wood Fiber Sci 46(1):15-28.
14. Khoury BM, Bigelow EM, Smith L, Schlecht SH, Scheller EL, Andarawis-Puri N, Jepsen KJ (2015) The use of nanocomputed tomography to enhance musculoskeletal research. Connect Tissue Res 56(2):106-119.10.3109/03008207.2015.1005211 ↗
15. Letiche M, Eustache E, Freixas J, Demorti ´ ere A, De Andrade ` V, Morgenroth L, Tilmant P, Vaurette F, Troadec D, Roussel P, Brousse T, Lethien C (2017) Atomic layer deposition of functional layers for on chip 3D Li-ion all solid state microbattery. Adv Energy Mater 017;7:1601402.10.1002/aenm.201601402 ↗
16. Lim C, Yan B, Kang H, Song Z, Lee WC, De Andrade V, De Carlo F, Yin L, Kim Y, Zhu L (2016) Analysis of geometric and electrochemical characteristics of lithium cobalt oxide electrode with different packing densities. J Power Sources 328:46-55.10.1016/j.jpowsour.2016.07.119 ↗
17. Mannes D, Marone F, Lehmann E, Stampanoni M, Niemz P (2010) Application areas of synchrotron radiation tomographic microscopy for wood research. Wood Sci Technol 44:67-84.10.1007/s00226-009-0257-2 ↗
18. Mayo SC, Chen F, Evans R (2010) Micron-scale 3D imaging of wood and plant microstructure using high-resolution x-ray phase-contrast microtomography. J Struct Biol 171:182-188.10.1016/j.jsb.2010.04.001 ↗
19. McKinley PE, Ching DJ, Kamke FA, Zauner M, Xiao X (2016) Micro X-ray computed tomography of adhesive bonds in wood. Wood Fiber Sci 48:2-16.
20. Metscher BD (2013) Biological applications of X-ray microtomography: Imaging microanatomy, molecular expression and organismal diversity. Microsc Anal (Am Ed) 27(2):13-16.
21. Miqueles EX, Rinkel J, O'Dowd F, Bermudez JSV (2014) ´ Generalized Titarenko's algorithm for ring artefacts reduction. J Synchrotron Radiat 21(6):1333-1346.10.1107/S1600577514016919 ↗
22. Modzel G, Kamke FA, De Carlo F (2011) Comparative analysis of a wood-adhesive bondline. Wood Sci Technol 45:147-158.10.1007/s00226-010-0304-z ↗
23. Paris J, Kamke F (2015) Quantitative wood-adhesive penetration with X-ray computed tomography. Int J Adhes Adhes 61:71-80.10.1016/j.ijadhadh.2015.05.006 ↗
24. Paris J, Kamke FA, Mbachu R, Gibson S (2014) Phenol formaldehyde adhesives formulated for advanced X-ray imaging in wood-composite bondlines. J Mater Sci 42(2):580-591.10.1007/s10853-013-7738-2 ↗
25. Pelt DM, Batenburg KJ (2015) Accurately approximating algebraic tomographic reconstruction by filtered backprojection. Pages 158–161 in Proc. 2015 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine.
26. Schindelin J, Arganda-Carreras I, Frise E, Kaynig V, Longair M, Pietzsch T, Preibisch S, Rueden C, Saalfeld S, Schmid B, Tinevez J-Y, White DJ, Hartenstein V, Eliceiri K, Tomancak P, Cardona A (2012) Fiji: An open-source platform for biological-image analysis. Nat Methods 9(7):676-682.10.1038/nmeth.2019 ↗
27. Schneider P, Stauber M, Voide R, Stampanoni M, Donahue LR, Muller R (2007) Ultrastructural properties in cortical ¨ bone vary greatly in two inbred strains of mice as assessed by synchrotron light based micro- and nano-CT. J Bone Miner Res 22(10):1557-1569.10.1359/jbmr.070703 ↗
28. Shearing PR, Bradley RS, Gelb J, Lee SN, Atkinson A, Withers PJ, Brandon NP (2011) Using synchrotron X-ray nano-CT to characterize SOFC electrode microstructures in three-dimensions at operating temperature. Electrochem Solid-State Lett 14(10):B117-B120.10.1149/1.3615824 ↗
29. Standfest G, Kranzer S, Petutschnigg A, Dunky M (2010) Determination of the microstructure of an adhesive-bonded medium density fiberboard (MDF) using 3-D submicrometer computer tomography. J Adhes Sci Technol 24:1501-1514.10.1163/016942410X501052 ↗
30. Steppe K, Cnudde V, Girard C, Lemeur R, Cnudde J-P, Jacobs P (2004) Use of X-ray computed microtomography for non-invasive determination of wood anatomical characteristics. J Struct Biol 148:11-21.10.1016/j.jsb.2004.05.001 ↗
31. Stockel F, Konnerth J, Moser J, Kantner W, Gindl-Altmutter ¨ W (2012) Micromechanical properties of the interphase in pMDI and UF bond lines. Wood Sci Technol 46:611-620.10.1007/s00226-011-0432-0 ↗
32. Trtik P, Dual J, Keunecke D, Mannes D, Niemz P, Stahli P, ¨ Stampanoni M (2007) 3D imaging of microstructure of spruce wood. J Struct Biol 159:46-55.10.1016/j.jsb.2007.02.003 ↗
33. Vogt S (2003) MAPS: A set of software tools for analysis and visualization of 3D X-ray fluorescence data sets. J Phys IV 104:635-638.10.1051/jp4:20030160 ↗
34. Xu D, Zhang Y, Zhou H, Meng Y, Wang S (2016) Characterization of adhesive penetration in wood bond by means of scanning thermal microscopy (SThM). Holzforschung 70(4):323-330.10.1515/hf-2014-0360 ↗
35. Zauner M, Keunecke D, Mokso R, Stampanoni M, Niemz P (2012) Synchrotron-based tomographic microscopy (SbTM) of wood: Development of a testing device and observation of plastic deformation of uniaxially compressed Norway spruce samples. Holzforschung 66(8): 973-979.10.1515/hf-2011-0192 ↗