FIRE DESIGN OF CLT IN EUROPE

Birgit Anna-Lisa Östman, Joachim Schmid, Michael Klippel, Alar Just, Norman Werther, Daniel Brandon

Wood and Fiber Science· Volume 50· Issue Special

Abstract

The fire safety design of cross-laminated timber (CLT or X-Lam) in Europe is governed by the Construction Products Regulation and its essential requirements, as for all other building products. These requirements are mandatory, to be used in all European countries. They include classification systems for reaction to fire of building products, fire resistance of building elements, and structural Eurocodes. The reaction-to-fire performance of CLT in accordance with the European classification system is specified. Higher classes can be reached by chemical treatments, but the durability of the reaction-to-fire performance needs to be fulfilled according to a new European system. The fire resistance design of CLT building elements is not included in Eurocode 5, the structural Eurocode for timber, but can be either tested according to European standards or calculated by using design methods being developed recently. This article provides information about both reaction to fire and fire resistance of CLT in Europe.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Flame retardant materials and properties · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (45)

Show source-provided references
1. Babrauskas V (2005) Charring rate of wood as a tool for fire investigations. Fire Saf J 40(6):528-554.10.1016/j.firesaf.2005.05.006 ↗
2. Brandon D (2016) Practical method to determine the contribution of structural timber to the heat release rate and fire temperature of post-flashover compartment fires. SP Technical Research Institute of Sweden, SP Rapport 2016:68, Stockholm, Sweden.
3. Brandon D and Ostman B (2017) Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 1 – Literature Review. Report FPRF-2016-22, Fire Protection Research Foundation, NFPA, USA.
4. Hopkin D, Anastov S, Brandon D (2017) Reviewing the veracity of a zone-model-based-approach for the assessment of enclosures formed of exposed CLT. In M Gillie, Y Wang Applications of Fire Engineering - proceedings of the International Conference of Applications of Structural Fire Engineering, Manchester, UK, September 2017, CRC Press Taylor & Francis Group, London, pp. 151-160.10.1201/9781315107202-18 ↗
5. COMMISSION DELEGATED REGULATION (EU) 2017/ 2293 on the conditions for classification, without testing, of cross laminated timber products covered by the harmonised standard EN 16351 and laminated veneer lumber products covered by the harmonised standard EN14374 with regard to their reaction to fire. Official Journal of the European Union 13.12.2017. European Commission, Brussels.
6. CONSTRUCT 01/491 rev 3 (2004) Classification of products of known and stable performance—Procedural aspects. European Commission, Brussels.
7. Construction Products Regulation (CPR) (2013) Official Journal Council Directive 89/106/EEC OJ L 88 of April 4, 2011. European Commission, Brussels.
8. EN 520:2004. Gypsum plasterboards—Definitions, requirements and test methods. European Standard. CEN—European Committee for Standardization, Brussels.
9. EN 1366 series. Fire resistance tests for service installations. European Standard. CEN—European Committee for Standardization, Brussels.
10. EN 1991-1-2:2002. Eurocode 1. Actions on structures—Part 1-2: General actions—Actions on structures exposed to fire. European Standard. CEN—European Committee for Standardization, Brussels.
11. EN1995-1-2:2004. Eurocode 5. Design of timber structures—Part 1-2: General—Structural fire design. European Standard. CEN—European Committee for Standardization, Brussels.
12. prEN 13381-7:2017. Test methods for determining the contribution to the fire resistance of structural members. Part 7: Applied protection to timber members. Draft European Standard. CEN—European committee for standardization, Brussels.
13. EN 13501-1:2009. Fire classification of construction products and building elements—Part 1: Classification using test data from reaction-to-fire tests. European Standard. CEN—European committee for standardization, Brussels.
14. EN 13501-2:2009. Fire classification of construction products and building elements—Part 2: Classification using data from fire resistance tests, excluding ventilation services. European Standard. CEN European Committee for Standardization, Brussels.
15. EN 14135:2005. Coverings—Determination of fire protection ability. CEN European Standard. European Committee for Standardization, Brussels.
16. prEN 16351. Timber structures—Cross laminated timber—Requirements. Draft European Standard. CEN, European Committee for Standardization, Brussels, 2015 (final version expected in 2019).
17. EN 16755:2017. Durability of reaction to fire performance of FRT wood-based products in interior and exterior end-use applications. European Standard. CEN—European Committee for Standardization, Brussels.
18. Frangi A, Fontana M (2003) Charring rates and temperature profiles of wood sections. Fire Mater 27(2):91-102.10.1002/fam.819 ↗
19. Gerard R, Barber D, Wolski A (2013) Fire safety challenges of tall wood buildings. Fire Protection Research Foundation (FPRF), Quincy, MA.
20. Hakkarainen T (2002) Post-flashover fires in light and heavy timber construction compartments. J Fire Sci 20:133-175.10.1177/0734904102020002074 ↗
21. Hopkin D, El-Rimawi J, Silberschmidt V, Lennon T (2011) An effective thermal property framework for softwood in parametric design fires: Comparison of the Eurocode 5 parametric charring approach and advanced calculation models. Constr Build Mater 25(5):2584-2595.10.1016/j.conbuildmat.2010.12.002 ↗
22. Hosser D, Kampmeier B (2008) Bewertung des Brandverhaltens unbekleideter flachiger massiver Holzbauteile im Hinblick auf die Einsatzmoglichkeiten im mehrgeschossigen Holzbau unter Berucksichtigung des geltenden nationalen Sicherheitsniveaus sowie der DIN EN 1995-1-2. Forschungsauftrag der deutschen Gesellschaft fur Holzforschung. Braunschweig, Deutschland.
23. Just A, Schmid J, Konig J (2010) Failure times of gypsum boards. In Proceedings of the 6th International Conference Structures in Fire: Structures in Fire, East Lansing, MI, USA, 2.-4.6.2010. DesTech Publications Inc, 593-601.
24. Klippel M, Schmid J, Frangi A (2016) Fire design of CLT. In Proc. Joint Conference ofCOST Actions FP1402&FP1404 Cross Laminated Timber: A CompetitiveWood Product for Visionary and Fire Safe Buildings. March 10, 2016. KTH Royal Institute of Technology, Stockholm, Sweden.
25. Lange D, Bostrom L, Schmid J, Albrektsson J (2014) The influence of parametric fire scenarios on structural timber performance and reliability. SP-Technical Research Institute of Sweden, Boras, Sweden. SP Report 2014:35.
26. LeVan S, Holmes CA (1986) Effectiveness of fire-retardant treatments for shingles after 10 years of outdoor weathering. FPL Forest Products Laboratory, Madison, WI. Research Paper FPL 474.
27. McGregor CJ (2013) Contribution of cross laminated timber panels to fires. Department of Civil and Environmental Engineering, Carleton University, Ottawa, ON, Canada.10.22215/etd/2013-06885 ↗
28. Medina Hevia AR (2014) Fire resistance of partially protected cross-laminated timber rooms. Master thesis, Department of Civil and Environmental Engineering Carleton University, Ottawa, ON, Canada.
29. Merk M, Werther N, Grafe M, Fulle C, Leopold N, Sprinz D, Busch M, Brunn M (2014) Erarbeitung weiterfuhrender Konstruktionsregeln/-details fur mehrgeschossige Gebaude in Holzbauweise der Gebaudeklasse 4. Fraunhofer IRB Verlag, Stuttgart, Deutschland.
30. Nussbaum RM (1988) The effect of low concentration fire retardant impregnations on wood charring rate and char yield. J Fire Sci 6:290-307.10.1177/073490418800600405 ↗
31. Ostman B, Voss A, Hughes A, Hovde PJ, Grexa O (2001) Durability of fire retardant treated wood products at humid and exterior conditions—Review of literature. Fire Mater 25:95-104.10.1002/fam.758 ↗
32. Ostman B, Mikkola E (2010) European classes for the reaction to fire performance of wood-based panels. Fire Mater 34:315-332.10.1002/fam.1054 ↗
33. Ostman B, Mikkola E, Stein R, Frangi A, Konig J, Dhima D, Hakkarainen T, Bregulla J (2010) Fire safety in timber buildings—European Guideline. SP-Technical Research Institute of Sweden. SP Report 2010:19.
34. Ostman B, Mikkola E (2010) European classes for the reaction to fire performance of wood-based panels. Fire Mater 34:315-332.10.1002/fam.1054 ↗
35. Ostman B, Tsantaridis L (2017) Durability of the reaction to fire performance of fire retardant treated wood products in exterior applications—A ten years report. Int Wood Prod J 8(2):94-100.10.1080/20426445.2017.1330229 ↗
36. Schaffer EL, Marx CM, Bender DA, Woeste FE (1986) Strength validation and fire endurance of glued-laminated timber beams. United States Department of Agriculture, Forest Products Laboratory, Research Paper FPL 467, Madison, WI.
37. Schleifer V (2009) Zum Verhalten von raumabschliessenden mehrschichtigen Holzbauteilen im Brandfall. PhD Thesis No. 18156, ETH Zurich, Zurich, Switzerland.
38. Schmid J, Konig J, Kohler J (2010) Fire-exposed cross laminated timber-Modelling and tests. In Conference Proceedings 11th World Conference on Timber Engineering (WCTE 2010), 20-24 June 2010, Trentino, Italy.
39. Schmid J, Brandon D, Santomaso A, Wickstrom U, Frangi A (2016) Timber under real fire conditions—The influence of oxygen content and gas velocity on the charring behaviour. In Proc. 9th International Conference on Structures in Fire Conference, Princeton, NJ 8-10 June, 2016.
40. Schmid J, Klippel M, Daniel B, Werther N (2017a) Thermal exposure of wood in standard fire tests and post-flash over fires. Technical Note. Fire Mater, Accepted for publication February 2018.
41. Schmid J, Klippel M, Fahrni R, Frangi A (2017b) Fire resistance tests of cross-laminated timber and solid timber deck plates, Report Fr-2017-03. ETH Zurich, Zurich, Switzerland.
42. Teibinger M (2011) Brandschutz im Detail. Holzbau – die neue quadriga (4), 39-43.
43. Teibinger M, Matzinger I (2012) Brandabschottung im Holzbau. Holzforschung, Austria.
44. Teibinger M, Matzinger I (2013) Construction with Cross-Laminated Timber in Multi-Storey Buildings—Focus on Building Physics. Holzforschung, Austria.
45. Wickstrom U (2016) Temperature Calculation in Fire Safety Engineering, pp 153-171. Springer International Publishing Switzerland10.1007/978-3-319-30172-3 ↗