Decreased Staphylococcus aureus biofilm growth on anodized nanotubular titanium and the effect of electrical stimulation
Source abstract
Abstract
Infection is a major problem in orthopedics leading to implant failure. It is a challenging task to treat orthopedic implant infection, which may lead to implant replacement and, in severe cases, may result in amputation and mortality. Infection poses an even further risk as bacteria are beginning to develop resistance against commonly used antibiotics. Therefore, in this research a combination of various approaches was used to fight implant infection without resorting to the use of antibiotics. Specifically, conventional titanium was altered through a process of anodization and electrical stimulation to reduce Staphylococcus aureus growth. It was shown that when a 15-30 V electrical stimulation was coupled with anodized nanotubular titanium a significant decrease in S. aureus biofilm formation was observed, compared with non-anodized and non-electrically stimulated titanium after 2 days culture. The decrease in biofilm formation observed here was explained by the presence of fluorine on the surfaces of anodized nanotubular titanium. Thus, coupling the positive influences of anodization and electrical stimulation could be a promising way to fight titanium-based orthopedic device-related infections.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. The epidemiology of revision total hip arthroplasty in the United States10.2106/JBJS.H.00155 ↗
2. The significance of infection related to orthopedic devices and issues of antibiotic resistance10.1016/j.biomaterials.2005.11.044 ↗
3. Molecular and antibiofilm approaches to prosthetic joint infection10.1097/01.blo.0000087324.60612.93 ↗
4. Nitric oxide-releasing sol-gels as antibacterial coatings for orthopedic implants10.1016/j.biomaterials.2004.03.031 ↗
5. Mechanism of electrical enhancement of efficacy of antibiotics in killing biofilm bacteria10.1128/AAC.38.12.2803 ↗
6. The relationship between the nanostructure of titanium surfaces and bacterial attachment10.1016/j.biomaterials.2009.09.081 ↗
7. Bacterial biofilms: a common cause of persistent infections10.1126/science.284.5418.1318 ↗
8. Factors in pin tract infections
9. External fixation of complex femoral shaft fractures10.1007/s00264-006-0187-7 ↗
10. Decreased Staphylococcus epidermis adhesion and increased osteoblast functionality on antibiotic-loaded titania nanotubes10.1016/j.biomaterials.2007.07.037 ↗
11. Anodized Ti and Ti6Al4V possessing nanometer surface features enhances osteoblast adhesion10.1166/jbn.2005.008 ↗
12. In vitro osteoblast response to anodized titanium and anodized titanium followed by hydrothermal treatment10.1002/jbm.a.10490 ↗
13. Titanium dioxide nanotubes enhance bone bonding in vivo10.1002/jbm.a.32463 ↗
14. Effect of ultrafine-grained titanium surfaces on adhesion of bacteria10.1007/s00253-009-1944-5 ↗
15. Influence of nanophase titania topography on bacterial attachment and metabolism
16. Impact of nanoscale roughness of titanium thin film surfaces on bacterial retention10.1021/la902623c ↗
17. Impact of nano-topography on bacterial attachment10.1002/biot.200700244 ↗
18. Influence of the nano-micro structure of the surface on bacterial adhesion10.1590/S1516-14392007000100004 ↗
19. Electrical stimulation for wound healing: a review of evidence from in vitro studies, animal experiments, and clinical trials10.1177/1534734605275733 ↗
20. The electricidal effect: reduction of Staphylococcus and Pseudomonas biofilms by prolonged exposure to low-intensity electrical current10.1128/AAC.00680-08 ↗
21. Electric-current-induced detachment of Staphylococcus epidermidis strains from surgical stainless steel10.1002/jbm.b.20015 ↗
22. Electric current-induced detachment of Staphylococcus epidermidis biofilms from surgical stainless steel10.1128/AEM.70.11.6871-6874.2004 ↗
23. Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidis10.1016/j.biomaterials.2004.04.052 ↗
24. The electricidal effect is active in an experimental model of Staphylococcus epidermidis chronic foreign body osteomyelitis10.1128/AAC.00432-09 ↗
25. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model10.1016/j.biomaterials.2007.01.001 ↗
26. Greater osteoblast proliferation on anodized nanotubular titanium upon electrical stimulation
27. The effect of biphasic electrical stimulation on osteoblast function at anodized nanotubular titanium surfaces10.1016/j.biomaterials.2010.01.078 ↗
28. Fabrication of tapered, conical-shaped titania nanotubes10.1557/JMR.2003.0362 ↗
29. A review on highly ordered, vertically oriented TiO2 nanotube arrays: fabrication, material properties, and solar energy applications10.1016/j.solmat.2006.04.007 ↗
30. Fabrication and characterization of functionally graded nano–micro porous titanium surface by anodizing10.1002/jbm.b.31124 ↗
31. Enhanced osteoblast functions on anodized titanium with nanotube-like structures10.1002/jbm.a.31551 ↗
32. Jin S
33. Stem cell fate dictated solely by altered nanotube dimension10.1073/pnas.0813200106 ↗
34. TiO2 nanotubes: self-organized electrochemical formation, properties and applications10.1016/j.cossms.2007.08.004 ↗
35. Decreased bacterial adhesion to surface-treated titanium10.1177/039139880502800711 ↗
36. Bacterial adhesion on commercially pure titanium and anatase-coated titanium healing screws: an in vivo human study10.1902/jop.2010.100061 ↗
37. The influence of cell and substratum surface hydrophobicities on microbial attachment10.1016/j.jbiotec.2004.02.012 ↗
38. Hydrophobic and electrostatic parameters in bacterial adhesion10.1007/BF00878244 ↗
39. Bacterial adhesion to surface hydrophilic and hydrophobic contact lenses10.1016/S0142-9612(01)00159-4 ↗
40. The DLVO theory in microbial adhesion10.1016/S0927-7765(99)00029-6 ↗
41. Staphylococcus aureus adhesion to titanium oxide surfaces coated with non-functionalized and peptide-functionalized poly(L-lysine)-grafted-poly(ethylene glycol) copolymers10.1016/j.biomaterials.2003.11.033 ↗
42. Fibronectin, fibrinogen, and laminin act as mediators of adherence of clinical staphylococcal isolates to foreign material10.1093/infdis/158.4.693 ↗
43. Plasma-based fluorine ion implantation into dental materials for inhibition of bacterial adhesion10.4012/dmj.25.684 ↗
44. Antibacterial activity of four glass ionomer cements used in atraumatic restorative treatment10.1007/s10856-007-3035-4 ↗
45. Susceptibility of oral bacteria to various fluoride salts10.1177/00220345820610062701 ↗
46. Inhibition of microbial adherence and growth by various glass ionomers invitro10.1016/0109-5641(92)90047-G ↗