journal article·2022-09-14Open access

The Influence of Foam Discontinuity in the Shear Zone of Structural Insulated Panel Beams

R. Shmulsky, L. Khademibami, C.A. Senalik, R.D. Seale, R.J. Ross

Wood and Fiber Science· Volume 54· Issue 3

Abstract

The effect of foam discontinuity in the shear zone of structural insulated panel (SIP) beams was investigated in the current research. Two depths of 15.24 cm and 31.11 cm (6.5 in and 12.25 in) (SIPs) were evaluated in 1/3-point bending. Panels were sawn into beams, each approximately 29.84 cm (11.75 in.) wide, for mechanical testing. Half of the panels had joints or discontinuities in the foam layer in a location that was subject to shear stress during the bending tests. Half of the panels had joints or discontinuities in the foam layer in a location that was subject to shear stress during the bending tests. Half of the panels did not have joints or discontinuities in the foam layer in the locations that were subject to shear stress during the bending tests. The specimens with no foam discontinuity, stressed in shear, were approximately twice as strong as the specimens with a foam discontinuity. This finding has implications for routine testing and evaluation as well as for allowable properties. In the case of routine testing, foam discontinuities should purposefully be located in the zone of maximum shear as these appear to be a limiting factor. In cases where a producer manufactures SIPs with zero discontinuities, it may be prudent to seek premium value as those panels would achieve superior properties. Keywords: Structural insulated panels (SIPs), shear stress, bending test, foam, joints and routine testing.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Analysis of Composite Materials · Material Properties and Processing · Cellular and Composite Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Aldrich RA, Arena L, Zoeller W (2010) Practical residential wall systems: R-30 and beyond in Proceedings of Building Enclosure Science and Technology (BEST2) Conference, National Institute of Building Sciences, Washington, DC.
2. American Society of Testing and Materials (ASTM) (2015a) Standard test methods of static tests of lumber in structural sizes. American Society of Testing and Materials, West Conshohocken, PA. ASTM D198-15.
3. American Society of Testing and Materials (ASTM) (2013) Standard test methods for mechanical properties of lumber and wood-base structural material. American Society of Testing and Materials. ASTM D4761-13. ASTM, West Conshohocken, PA.
4. American Society of Testing and Materials (ASTM) (2015b) ASTM, West Conshohocken, PA.
5. American Society of Testing and Materials (ASTM) (2015b) Standard specification for evaluation of duration of load and creep effects of wood and wood-based products. ASTM D6815-15. ASTM, West Conshohocken, PA.
6. Cox NI, Hamel SE (2021) Static modeling of plywood-polyurethane structural insulated panels in bending. J Struct Eng 147(2):04020334.10.1061/(ASCE)ST.1943-541X.0002915 ↗
7. McDonald D, Begal M, Senalik CA, Ross R, Skaggs TD, Yeh B, Williamson T 2014. Creep behavior of structural insulated panels (SIPs): Results from a pilot study. Research Note FPL-RN-0332. U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI. 12 pp.10.2737/FPL-RN-332 ↗
8. McDonald DE, Begel M, Senalik CA, Williamson T (2018) Evaluation of creep performance of structural insulated panels (SIPs): Phase 2. Research Paper FPLRP-697. U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI. 12 pp.10.2737/FPL-RP-697 ↗
9. Mcintosh J, Guthrie C (2010) Structural insulated panels: A sustainable option for house construction in New Zealand. Int. J. Hous. Sci. 34(1):1-13.
10. Medina MA, King JB, Zhang M (2008) On the heat transfer rate reduction of structural insulated panels (SIPs) outfitted with phase change materials (PCMs). Energy 33(4):667-678.10.1016/j.energy.2007.11.003 ↗
11. Morley M 2000. Structural insulated panels: Strength and energy efficiency through structural panel construction. Taunton Press, Newton, CT.
12. Statistical Analysis System (SAS) Institute (2013) User guide: Statistics (Release 9.4). SAS Institute, Cary, NC.