journal article·2022-02-17Open access

Development of a modified standard termite test for mass timber products

Tamara S.F.A. França, C. Elizabeth Stokes, Juliet D. Tang

Wood and Fiber Science· Volume 54· Issue 1

Abstract

U.S. manufacturers are looking to expand the use of cross laminated timber panels (CLT) into the North American market, including states located in the southeast. However, there is no current assessment method for determining CLT vulnerability to the highly destructive native termites found throughout the U.S. The impact of these termites is particularly high in areas with suitable climate to their proliferation, such as the southeastern U.S. This study aimed to evaluate durability of CLT panels and to develop a laboratory assay to test susceptibility of this product to termites. Untreated CLT suffered mass loss of up to 43.8% in testing with an average visual rating of 7.2, indicating a moderate to severe attack with 10 to 30% of the cross-section of the product affected by termite intrusion. Recommendations were developed for inclusion in standardized testing protocols and will be presented to standards organizations as appropriate. The proposed method can also be applied to evaluate termite resistance of other mass lumber products such as parallel strand lumber, laminated veneer lumber, and Glulam.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Insect and Arachnid Ecology and Behavior · Forest Insect Ecology and Management · Insect and Pesticide Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Arango RA, Green F, Hintz K, Lebow PK, Miller RB (2006) Natural durability of tropical and native woods against termite damage by Reticulitermes flavipes (Kollar). Int Biodeterior Biodegradation 57(3):146-150.10.1016/j.ibiod.2006.01.007 ↗
2. Arango RA, Woodward BM, Lebow ST (2016) Evaluating the effects of post dip-treatment laser marking on resistance to feeding by subterranean termites. In Proc IRG Annual Meeting (ISSN 2000-8953), The International Research Group on Wood Protection, 19-22 July 2016, Lisbon, Portugal; IRG/WP 16-10854; Section 1 Biology.
3. American Society for Testing and Materials (ASTM) (2017) D 3345-17: Standard test method for laboratory evaluation of solid wood for resistance to termites, American Society for Testing and Material International, West Conshohocken, PA.
4. American Wood Protection Association (AWPA) (2020) E1-17: Laboratory methods for evaluating the termite resistance of wood-based materials. American Wood Protection Association Book of standards. American Wood Protection Association, Birmingham, AL.
5. Bobadilha GS, Stokes CE, Kirker G, Ahmed SA, Ohno KM, Lopes DJV (2021) Effect of exterior wood coatings on the durability of cross-laminated timber against mold and decay fungi. BioResources 15(4):8420-8433.10.15376/biores.15.4.8420-8433 ↗
6. Cappellazzi J, Konkler MJ, Sinha A, Morrell JJ (2020) Potential for decay in mass timber elements: A review of the risks and identifying possible solutions. Wood Mater Sci Eng 15(6):351-360.10.1080/17480272.2020.1720804 ↗
7. Ceccotti A, Sandhaas C, Yasumura M (2010) Seismic behavior of multistory cross-laminated timber buildings. In Proc International Convention of Society of Wood Science and Technology, Geneva, Switzerland CSA S-16. Design of Steel Structures. Ottawa, Canada: Canadian Standards Association.
8. França TSFA, França FJN, Arango RA, Woodward BM, Arantes MDC (2016) Natural resistance of plantation grown African mahogany (Khaya ivorensis and Khaya senegalensis) from Brazil to wood-rot fungi and subterranean termites. Int Biodeterior Biodegradation 107:88-91.10.1016/j.ibiod.2015.11.009 ↗
9. França TSFA, Stokes CE, Tang JD (2018a) Durability of cross laminated timber against termite damage. In Proc 61st international convention of society of wood science and technology and Japan wood research society. Monona, WI: Society for Wood Science and Technology. 10 pp.
10. Franc¸a TSFA, Stokes CE, Tang JD (2018b) Evaluation of cross-laminated timber resistance to termite attack. In Proc American Wood Protection Association Annual Meeting, 22-24 April 2018, Seattle, WA. 114:266-271.
11. Franc¸a TSFA, Stokes CE, Tang JD, Arango RA (2019) Utility of image software in quantification of termite damage on cross-laminated timber (CLT). In Proc 21st International Nondestructive Testing and Evaluation of Wood Symposium, 24-27 September 2019, Freiburg, Baden-W€urttemberg, Germany. General Technical Report FPL-GTR-272. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. pp. 643-649.
12. Frangi A, Fontana M, Hugi E, J€ubstl R (2009) Experimental analysis of cross-laminated timber panels in fire. Fire Saf J 44(8):1078-1087.10.1016/j.firesaf.2009.07.007 ↗
13. Gavric I, Fragiacomo M, Popovski M, Ceccotti A (2014) Behavior of cross-laminated timber panels under cyclic loads. Pages 689-702 in S Aicher, HW Reinhardt, H Garrecht, eds. Materials and joints in timber structures. The Netherlands: Springer.10.1007/978-94-007-7811-5_62 ↗
14. Grasser KK (2015) Development of cross laminated timber in the United States of America. MS thesis, University of Tennessee, Knoxville, TN. 115 pp.
15. Gulzow A, Richter K, Steiger R (2011) Influence of wood moisture content on bending and shear stiffness of cross laminated timber panels. Holz Roh-und Werkst 69(2): 193-197.10.1007/s00107-010-0416-z ↗
16. Hassan B, Morrell JJ (2021) Termite testing methods: A global review. J Test Eval 49(6):20200455.10.1520/jte20200455 ↗
17. He M, Sun X, Li Z, Feng W (2020) Bending, shear, and compressive properties of three- and five-layer cross- laminated timber fabricated with black spruce. J Wood Sci 66(38):1-17.10.1186/s10086-020-01886-z ↗
18. Kose C, Tylor AM (2012) Evaluation of mold and termite resistance of included sapwood in eastern redcedar. Wood Fiber Sci 44(3):319-324.
19. Laguarda-Mallo M, Espinoza O (2014) Outlook for cross- laminated timber in the United States. BioResources 9(4):7427-7443.10.15376/biores.9.4.7427-7443 ↗
20. Lim H, Tripathi S, Tang JD (2020) Bonding performance of adhesive systems for cross laminated timber treated with micronized copper azole type C (MCA-C). Constr Build Mater 232:1-10.10.1016/j.conbuildmat.2019.117208 ↗
21. Mankowski M, Shelton TG, Kirker G, Morrell J (2018) Ongoing field evaluation of Douglas-fir cross laminated timber in a ground proximity protected test in Mississippi. In Proc 114th American Wood Protection Association Annual Meeting, 22-24 April 2018, Seattle, WA. pp. 132-137.
22. Oliveira GL, Oliveira FL, Brazolin S (2018) Wood preservation for preventing biodeterioration of cross laminated timber (CLT) panels assembled in tropical locations. Procedia Structural Integrity 11:242-249.10.1016/j.prostr.2018.11.032 ↗
23. Pei S, Van de Lindt JW, Popovski M (2013) Approximate R-factor for cross-laminated timber walls in multistory buildings. J Archit Eng 19(4):245-255.10.1061/(ASCE)AE.1943-5568.0000117 ↗
24. Peterson C, Wagner TL, Mulrooney JE, Shelton TG (2006) Subterranean termites-their prevention and control in building. Home and Garden Bulletin 64. U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Starkville, MS. 38 pp.
25. Popovski M, Karacabeyli E (2012) Seismic behaviour of cross-laminated timber structures. Pages 335-344 in P Quenneville, ed. Proc World Conference on Timber Engineering, 16-19 July 2012, Auckland, New Zealand.
26. Rust MK, Su NY (2012) Managing social insects of urban importance. Annu Rev Entomol 57:355-375.10.1146/annurev-ento-120710-100634 ↗
27. SAS Institute (2013) SASVR software, version 9.4. Cary, NC: The SAS Institute Inc.
28. Shen Y, Schneider J, Tesfamariam S, Stiemer SF, Mu Z (2013) Hysteresis behavior of bracket connection in cross-laminated-timber shear walls. Constr Build Mater 48:980-991.10.1016/j.conbuildmat.2013.07.050 ↗
29. Singh T, Page D, Simpson I (2019) Manufactured structural timber building materials and their durability. Construction Structural Timber Building Materials and Their Durability 217:84-92.10.1016/j.conbuildmat.2019.05.036 ↗
30. Sinha A, Udele K, Cappellazzi J, Morrell JJ (2020) A method to characterize biological degradation of mass timber connections. Wood Fiber Sci 52(4):419-430.10.22382/wfs-2020-040 ↗
31. Smyth M (2018) Cross laminated timber for residential construction. MS thesis, KTH Royal Institute of Technology, Stockholm, Sweden. p. 95.
32. Steiger R, G€ulzow A, Gsel LD (2008) Non-destructive evaluation of elastic material properties of cross- laminated timber (CLT). Pages 29-30 in WF Gard and JWG van deKuilen, eds. Proc International Conference COST E53, 29-30 October 2008, Delft, The Netherlands.
33. Stokes CE, Tang JD, Shmulsky R (2017) Potential impact of subterranean termites on cross-laminated timber (CLT) in the Southeastern U.S. In Proc American Wood Protection Association Annual Meeting, 09-11 April 2018, Las Vegas, NV. 113:214-219.
34. Van de Kuilen JWG, Ceccotti A, Xia Z, He M (2011) Very tall wooden buildings with cross laminated timber. Procedia Eng 14:1621-1628.10.1016/j.proeng.2011.07.204 ↗
35. Wang JY, Stirling R, Morris PI, Taylor A, Lloyd J, Kirker G, Lebow S, Mankowski M, Barnes HM, Mor- rell JJ (2018) Durability of mass timber structures: A review of the biological risks. Wood Fiber Sci 50(Special Issue):110-127.10.22382/wfs-2018-045 ↗