Introduction
Source abstract
Abstract
The increasing interest in cross-laminated timber and mass timber construction has resulted in several publications covering manufacturing, use, and code/standard regulations.This special issue of Wood and Fiber Science highlights the differences and similarities in engineering code specifics between several geographic regions, namely Canada, Europe, New Zealand/Australia, and the United States and to a very limited degree Japan.This issue focuses on critical engineering design factors such as seismic performance, connection details, and fire performance, all critical engineering design elements.To a lesser extent, this issue touches on some of the biodegradation issues that must be examined, and the economic and environmental concerns, particularly of Europe and New Zealand/Australia.When we started this project, we hoped to have a full matrix such that we had articles from every region dealing with seismic, connection, fire, economics, and environmental issues.Unfortunately busy schedules and prior commitments have limited us to this partial matrix.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Structural Engineering and Vibration Analysis · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (87)
Show source-provided references
1. Adams J, Halchuk S, Allen T, Rogers GC (2015) Canada's 5th generation seismic hazard model, as prepared for the 2015 National Building Code of Canada in Proc. of the 11th Canadian Conference on Earthquake Engineering, July 21-24, 2015, Victoria, BC, Canada.10.4095/293907 ↗
2. Akbas T, Sause R, Ricles J, Ganey R, Berman J, Lotus S, Dolan JD, Pei S, van de Lindt J, Blomgren H (2017) Analytical and experimental lateral load response of self centering CLT walls. J Struct Eng 143(6):04017019.10.1061/(asce)st.1943-541x.0001733 ↗
3. Amini MO, van de Lindt JW, Rammer D, Pei S, Line P, Popovski M (2016) Determination of seismic performance factors for CLT building systems. WCTE 2016, Vienna, Austria.
4. ANSI/APA (2017) PRG 320, Standards for performance rated cross-laminated timber. American National Standard, APA, Tacoma, WA.
5. ASCE (2016) Minimum design loads for building and other structures. ASCE Standard ASC/SEI 7-16, American Society of Civil Engineers, Reston, VA.
6. BCBC (2012) Building code of British Columbia, Office of housing and construction standards. National Research Council, Victoria, BC, Canada.
7. Brandner R, Flatscher G, Ringhofer A, Schickhofer G, Thiel A (2016) Cross laminated timber (CLT): Overview and development. Eur J Wood Wood Prod 74(3):331-351.10.1007/s00107-015-0999-5 ↗
8. BSL Article 20 (2015) Guideline for building standard law, enforcement order and notification for structural design, p. 25, Article 20, Official Gazette Co-operation of Japan.
9. BSL Article 37 (2015) Guideline for building standard law, enforcement order and notification for structural design, p. 48, Article 37, Official Gazette Co-operation of Japan.
10. BSL (2016) Japan ministry of land, infrastructure, transport and tourism, building standard law. The Building Standard Law of Japan, Building Center of Japan, Tokyo, Japan.
11. Cassidy JF, et al. (2010) Canada's earthquakes: 'The good, the bad, and the ugly'. Geoscience Canada 37(1):1911-4850.
12. CEA (2018) China earthquake administration. http://www.cea.gov.cn/ (accessed November 2017).
13. Ceccotti A, Follesa M (2006) Seismic behaviour of multistorey XLam buildings in Proc. COST Action E29, International Workshop—Earthquake Engineering on Timber Structures, pages 81-95, Coimbra, Portugal.
14. Ceccotti A, Sandhaas C, Okabe M, Yasumura M, Minowa C, Kawai N (2013) SOFIE project–3D shaking table test on a seven-storey full-scale cross-laminated timber building. Earthquake Eng Struct Dyn 42(13):2003-202110.1002/eqe.2309 ↗
15. CEN (2001) EN 12512: 2001. Timber structures—Test methods—Cyclic testing of joints made with mechanical fasteners. European Committee for Standardization, Brussels, Belgium.
16. CEN (2004) Eurocode 8: Design of structures for earthquake resistance, Part 1: General rules, seismic actions and rules for buildings. European Committee for Standardization, Brussels, Belgium.
17. CEN (2008) EN 1995-1-1:2008. Eurocode 5: Design of timber structures—Part 1-1: General—Common rules and rules for buildings. European Committee for Standardization, Brussels, Belgium.
18. Centro Sismologico Nacional (2018) Sismicidad y terremotos en Chile. Centro Sismologico Nacional/Universidad de Chile, Santiago, Chile.
19. CSA O86 (2014) Engineering design in wood. Canadian Standards Association, Ottawa, Canada.
20. CSA O86 (2016) Supplement. Engineering design in wood. Canadian Standards Association, Ottawa, Canada.
21. DFL N°458 (1975) Ley General de Urbanismo y Construcciones.
22. Dimova S, Fuchs M, Pinto A, Sousa L, Nikolova B, Iannaccone S (2015) State of implementation of the Eurocodes in the European Union: Support to the implementation, harmonization and further development of the Eurocodes. Report 2015. EUR 27511. doi:10.2788/85493.10.2788/85493 ↗
23. DR AS NZS (2018) Timber structures-Part 1: Design methods. Standards New Zealand, 1720.1, Wellington, New Zealand.
24. DS N°47 Ministerio de Vivienda y Urbanismo (2017) Normativa de Urbanismo y Construcciones.
25. EN 16351 (2015) Timber structures—Cross-laminated timber—Requirements. European Committee for Standardization, Brussels, Belgium.
26. European Union (2011) Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC, European Union, Brussels, Belgium.
27. European Union (2016) The European construction sector. A global partner. Internal market, industry, entrepreneurship and SMEs directorate general energy directorate general. Joint Research Centre (JRC). https://ec.europa.eu (accessed November 2017).
28. FDMA, Fire and Disaster Management Agency (2006) Hanshin- Awaji Great Earthquake. www.fdma.go.jp/bn/1995/detail/941.html (accessed November 2017).
29. FDMA, Fire and Disaster Management Agency (2016) Higashi Nihon Great Earthquake. www.fdma.go.jp/bn/higaihou.html (accessed November 2017).
30. FEMA (2009) Quantification of building seismic performance factors: FEMA P695. Federal Emergency Management Agency, Washington, D.C.
31. Follesa M, Fragiacomo M, Casagrande D, Canetti D, Tomasi R, Piazza M, Vassallo D, Rossi S (2018) The new provisions for the seismic design of timber buildings in Europe. Engineering Structures, Special issue.10.1016/j.engstruct.2018.04.090 ↗
32. Follesa M, Fragiacomo M, Vassallo D, Piazza M, Tomasi R, Rossi S, Casagrande D (2015) A proposal for a new background document of chapter 8 of Eurocode 8, paper 48-7-3 in Proc. 2nd International Network on Timber Engineering Research (INTER), Sibenik, Croatia.
33. Gagnon S, Pirvu C (2012) Cross-laminated timber (CLT) handbook. FPInnovations, Vancouver, Canada. 594 pp.
34. Ganey R, Berman J, Akbas T, Loftus S, Daniel Dolan J, Sause R, Blomgren HE (2017) Experimental investigation of self-centering cross-laminated timber walls. J Struct Eng 143(10):04017135.10.1061/(asce)st.1943-541x.0001877 ↗
35. Gavric I, Fragiacomo M, Ceccotti A (2015) Cyclic behavior of CLT wall systems: Experimental tests and analytical prediction models. J Struct Eng 141(11):04015034.10.1061/(asce)st.1943-541x.0001246 ↗
36. GB 18306-2016 (2016) Seismic ground motion parameter zonation map of China. National Standard of the People's Republic of China, China Criterion Press, Beijing, China.
37. GB 50005 (2017) Code for design of timber structures. China Architecture and Building Press, Beijing, China.
38. GB 50011 (2001) Code for seismic design of buildings, National Standard of the People's Republic of China, China Building Industry Press, Beijing, China.
39. GB/T 51226 (2017) Multi-story and high rise timber buildings. China Architecture and Building Press, Beijing, China.
40. Giardini D, Woessner J, Danciu L, Cotton F, Crowley H, Grunthal G, Stucchi M (2013) Seismic Hazard Harmonization in Europe (SHARE): Online Data Resource. doi:10.12686/SED-00000001-SHARE.10.12686/SED-00000001-SHARE ↗
41. GNS Science (2018)Major faults in NewZealand. https://www.gns.cri.nz/Home/Learning/Science-Topics/Earthquakes/Major-Faults-in-New-Zealand (accessedNovember 2017).
42. Gonzalez P, Saavedra E, Perez E, Burgos C, Pi-a F, Wagner M (2014) Sistema constructivo en madera contralaminada para edificios. Servicios Forestales y de Exposiciones S.A., Santiago, Chile.
43. He M, Duo T, Zheng L (2016) State-of-the-art of research advances on multi-story timber and timber-hybrid structures. J Build Struct 37(10):1-9.
44. HERP (2017) Japanese Headquarters for Earthquake Research Promotion Report National Seismic Hazar Maps for Japan. www.jishin.go.jp/main/index-e.html (accessed November 2017).
45. HOWTEC (2016a) Guideline for 2016 CLT relative notifications. Japan Housing and Wood Technology Center, Tokyo, Japan.
46. HOWTEC (2016b) Design and construction manual for CLT buildings. Japan Housing and Wood Technology Center.
47. Hummel J (2017) Displacement-based seismic design for multi-storey cross-laminated timber buildings. PhD thesis, Kassel University Press, Kassel, Germany. 224 pp.
48. International Building Code (IBC) (2018) International Code Council, Washington, D.C.
49. Iqbal A (2015) Cross-laminated timber for building structures. SR336. BRANZ Report.
50. Kawai N, Miyake T, Yasumura M, Isoda H, Koshihara M, Nakajima S, Araki Y, Nakagawa T, Sato M (2016) Full scale shake table tests on five story and three story CLT building structures in Proc. 14th World Conference on Timber Engineering, August 22-25, 2016, Vienna, Austria.
51. Khazaradse G, Klotz J (2003) Short and long-term effects of GPS measured crustal deformation rates along the southcentral Andes. J Geophys Res 108(B6):1-15.
52. Johansen KW (1949) Theory of timber connections. Int Assoc Bridge Struct Eng 9:249-262.
53. Lauriola MP, SandhaasC(2006) Quasi-static and pseudo-dynamic tests onXLAMwalls and buildings in Proc. COST Action E29, International Workshop—Earthquake Engineering on Timber Structures, pages 119-133, Coimbra, Portugal.
54. Luco N, Ellingwood BR, Hamburger RO, Hooper JD, Kimball JK, Kircher CA (2007) Risk-targeted versus current seismic design maps for the conterminous United States in Proc. Structural Engineers Association of California Convention, Sacramento, CA.
55. Madariaga R (1998) Sismicidad de Chile. Fis Tierra 10:221-258.
56. Meyer A (1957) Die Tragfahigkeit von Nagelverbindungen bei statischer Belastung. Holz Roh Werkst 15(2):96-109.10.1007/BF02609174 ↗
57. Miyake T, Yasumura M, Kawai N, Isoda H, Koshihara M, Tsuchimoto T, Araki Y, Nakagawa T (2016) Structural possibility of CLT panel constructions in High seismic area in Proc. 14th World Conference on Timber Engineering, August 22-25, 2016, Vienna, Austria.
58. Moroder D, Smith T, Dunbar A, Pampanin S, Buchanan A (2018) Seismic testing of post-tensioned Pres-Lam core walls using cross laminated timber. Eng Struct 167:639-654.10.1016/j.engstruct.2018.02.075 ↗
59. NCh1198 (2007)Madera—Construcciones en madera—Calculo. Instituto Nacional de Normalizacion INN-Chile, Santiago de Chile.
60. NCh433 (1996) Diseno sismico de edificios. Instituto Nacional De Normalizacion, INN-Chile, Santiago de Chile.
61. NDS (2018) National design specification for wood construction. American National Standards Institute/American Wood Council (ANSI/AWC), Leesburg, VA.
62. NRC (2015) National building code of Canada 2015, Canadian commission on building and fire codes. National Research Council, Ottawa, Canada.
63. NRCAN (2016) Geological survey of Canada earthquake search (On-line Bulletin). Natural Resources Canada. http://earthquakescanada.nrcan.gc.ca/stndon/NEDB-BNDS/bull-eng.php.52 (accessed November 2017).
64. NZBC (2004) New Zealand building code. New Zealand Government, Wellington, New Zealand.
65. NZS (1993) 3603. Timber structures standard. Standard Association of New Zealand, Wellington, New Zealand.
66. NZS (2004) 1170.5. Structural design actions. Part 5: Earthquake actions—New Zealand. Standard Association of New Zealand, Wellington, New Zealand.
67. NZS (2006) 3101. Concrete structures standard Parts 1 & 2:The Design of concrete structures and commentary. Standard Association of New Zealand, Wellington, New Zealand.
68. NZS (2011) 3604. Timber framed buildings. Standard Association of New Zealand, Wellington, New Zealand.
69. Ottenhaus LM, Li M, Smith T, Quenneville P (2018) Overstrength of dowelled CLT connections under monotonic and cyclic loading. Bull Earthquake Eng 16(2):753-773.10.1007/s10518-017-0221-8 ↗
70. Parker J (2015) Timber takes on new forms. BRANZ, Build Magazine. Build 149.
71. Pei S, Lenon C, Kingsley G, Deng P (2017) Seismic design of cross-laminated timber platform buildings using a coupled shear wall concept. J Archit Eng 23(3):06017001.10.1061/(ASCE)AE.1943-5568.0000257 ↗
72. Pei S, van de Lindt JW, Popovski M (2013) Approximate R-factor for cross-laminated timber walls in multistory buildings. J Archit Eng 19(4):245-255.10.1061/(ASCE)AE.1943-5568.0000117 ↗
73. Pei S, van de Lindt JW, Popovski M, Berman JW, Dolan JD, Ricles JM, Sause R, Blomgren H-E, Rammer DR (2015) Cross laminated timber for seismic regions: Progress and challenges for research and implementation. J Struct Eng 142:E2514001.10.1061/(ASCE)ST.1943-541X.0001192 ↗
74. Perez E, Gonzalez P, Saavedra E, Tapia S, Torelli S, Orellana S (2017) Mechanical characterization and hysteretic behavior of CLT panels made of Chilean radiata pine in Proc. 16th World Conference on Earthquake Engineering, January 9-13, 2017, Santiago, Chile.
75. Pina F, Gonzalez P, Burgos C, Saavedra E (2015) Seismic design of amid-rise building inChile using radiate pine cross laminated timber in Proc. 11th Canadian Conference on Earthquake Engineering, July 21-24, 2015, BC, Canada.
76. Popovski M, Gavric I (2015) Performance of a 2-story CLT house subjected to lateral loads. J Struct Eng 142(4):E4015006.10.1061/(ASCE)ST.1943-541X.0001315 ↗
77. Popovski M, Schneider J, Schweinsteiger M (2010) Lateral load resistance of cross laminated wood panels. Pages 20-21, Curran Associates in Proc. 11thWorld Conference on Timber Engineering, June 20-24, 2010, Riva del Garda, Italy.
78. Priestley MJN, Calvi GM, KowalskyMJ (2007) Displacement based seismic design of structures. IUSS Press, Pavia, Italy.721 pp.
79. SDPWS (2015) ANSI/AWC Special design provisions for wind and seismic. AmericanWood Council, Leesburg, VA.
80. Shahnewaz M, Tannert T, Alam MS, Popovski M (2017) Inplane stiffness of cross-laminated timber panels with openings. Struct Eng Int 27(2):217-223.10.2749/101686617X14881932436131 ↗
81. Stirling M, McVerry G, Gerstenberger M, Litchfield N, Van Dissen R, Berryman K, Lamarche G (2012) National seismic hazard model for New Zealand: 2010 Update. Bull Seismol Soc Am 102(4):1514-1542.10.1785/0120110170 ↗
82. van de Lindt JW, Amini MO, Rammer D, Pei S, Line P, Popovski M (2016) Progress in developing seismic performance factors for cross laminated timber in the United States via the FEMA P695 methodology in Proc. ASCE Structures Congress, April 3-5, Boston, MA.
83. Woessner J, Laurentiu D, Giardini D, Crowley H, Cotton F, Grunthal G, Hiemer S (2015) The 2013 European seismic hazard model: key components and results. Bull Earthquake Eng 13(12):3553-3596.10.1007/s10518-015-9795-1 ↗
84. Xiong H, Ouyang L, Wu Y (2016a) State-of-the-art on research of tall wood buildings. J Tongji Univ 44(9):1297-1306. (Natural Science).
85. Xiong H, Ouyang L, Wu Y (2016b) Preliminary design of a novel hybrid tall building with concrete frame-tube and light wood boxes in Proc. World Conference on Timber Engineering, August 22-25, 2016, Vienna, Austria.
86. Yasumura M, Kobayashi K, Okabe M, Miyake T, Matsumoto K (2015) Full-scale tests and numerical analysis of low-rise CLT structures under lateral loading. J Struct Eng 142(4): E4015007.10.1061/(ASCE)ST.1943-541X.0001348 ↗
87. Zhang X, Yang G, Lu X, Li M, Yang Z (2009) Relation between the characteristics of strong earthquake activities in Chinese mainland and the Wenchuan earthquake. J Earth Sci 22:505-518.10.1007/s11589-009-0505-4 ↗