Recent advances and directions in the development of bioresorbable metallic cardiovascular stents: Insights from recent human and in vivo studies
Source abstract
Abstract
Over the past two decades, significant advancements have been made regarding the material formulation, iterative design, and clinical translation of metallic bioresorbable stents. Currently, magnesium-based (Mg) stent devices have remained at the forefront of bioresorbable stent material development and use. Despite substantial advances, the process of developing novel absorbable stents and their clinical translation is time-consuming, expensive, and challenging. These challenges, coupled with the continuous refinement of alternative bioresorbable metallic bulk materials such as iron (Fe) and zinc (Zn), have intensified the search for an ideal absorbable metallic stent material. Here, we discuss the most recent pre-clinical and clinical evidence for the efficacy of bioresorbable metallic stents and material candidates. From this perspective, strategies to improve the clinical performance of bioresorbable metallic stents are considered and critically discussed, spanning material alloy development, surface manipulations, material processing techniques, and preclinical/biological testing considerations. STATEMENT OF SIGNIFICANCE: Recent efforts in using Mg, Fe, and Zn based materials for bioresorbable stents include elemental profile changes as well as surface modifications to improve each of the three classes of materials. Although a variety of alloys for absorbable metallic stents have been developed, the ideal absorbable stent material has not yet been discovered. This review focuses on the state of the art for bioresorbable metallic stent development. It covers the three bulk materials used for degradable stents (Mg, Fe, and Zn), and discusses their advances from a translational perspective. Strategies to improve the clinical performance of bioresorbable metallic stents are considered and critically discussed, spanning material alloy development, surface manipulations, material processing techniques, and preclinical/biological testing considerations.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Corrosion Behavior and Inhibition · Electrospun Nanofibers in Biomedical Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Heart disease and stroke statistics—2020 update: a report from the American Heart Association
2. Heart disease and stroke statistics—2018 update: a report from the American Heart Association10.1161/CIR.0000000000000558 ↗
3. Stent thrombosis: a clinical perspective
4. Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen10.1016/S0735-1097(99)00486-6 ↗
5. Controlled slow-release drug-eluting stents for the prevention of coronary restenosis: recent progress and future prospects10.1021/acsami.5b01993 ↗
6. Fully bioresorbable vascular scaffolds: lessons learned and future directions10.1038/s41569-018-0124-7 ↗
7. In-stent neoatherosclerosis: a final common pathway of late stent failure10.1016/j.jacc.2011.10.909 ↗
8. Bare metal stent thrombosis and in-stent neoatherosclerosis
9. Neoatherosclerosis: overview of histopathologic findings and implications for intravascular imaging assessment10.1093/eurheartj/ehv205 ↗
10. Bioresorbable scaffold: the emerging reality and future directions10.1161/CIRCRESAHA.117.310275 ↗
11. Evolution of metallic cardiovascular stent materials: a comparative study among stainless steel, magnesium and zinc10.1016/j.biomaterials.2019.119641 ↗
12. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
13. Current status and future direction of biodegradable metallic and polymeric vascular scaffolds for next-generation stents10.1016/j.actbio.2017.07.019 ↗
14. Bioresorbable metals in cardiovascular stents: material insights and progress
15. Zinc-based alloys for degradable vascular stent applications10.1016/j.actbio.2018.03.005 ↗
16. Towards revealing key factors in mechanical instability of bioabsorbable Zn-based alloys for intended vascular stenting10.1016/j.actbio.2020.01.028 ↗
17. Design of biodegradable, implantable devices towards clinical translation
18. Current status and outlook on the clinical translation of biodegradable metals10.1016/j.mattod.2018.05.018 ↗
19. Next-generation bioresorbable vascular scaffolds: when to get our hopes up?
20. Endogenous cell seeding: remnant endothelium after stenting enhances vascular repair10.1161/01.CIR.94.11.2909 ↗
21. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model10.1016/0735-1097(92)90476-4 ↗
22. Coronary artery stretch versus deep injury in the development of in-stent neointima10.1136/heart.88.4.401 ↗
23. The effects of stenting on coronary endothelium from a molecular biological view: time for improvement?10.1111/jcmm.13936 ↗
24. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial10.1161/01.CIR.103.23.2816 ↗
25. Endovascular stent design dictates experimental restenosis and thrombosis10.1161/01.CIR.91.12.2995 ↗
26. Hemodynamically driven stent strut design10.1007/s10439-009-9719-9 ↗
27. Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: frequency, predictors and clinical outcome10.1016/S0735-1097(96)00452-4 ↗
28. In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia10.1016/S0735-1097(97)00450-6 ↗
29. Inflammation and restenosis in the stent era10.1161/01.ATV.0000037100.44766.5B ↗
30. Inflammation in atherosclerosis10.1161/ATVBAHA.108.179705 ↗
31. Syndromes of accelerated atherosclerosis: role of vascular injury and smooth muscle cell proliferation10.1016/0735-1097(90)92845-S ↗
32. Levine · Circulation · 2016 · 134 · e12310.1161/CIR.0000000000000404 ↗
33. 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions
34. First biodegradable metal stent in a child with congenital heart disease: evaluation of macro and histopathology
35. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
36. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn
37. Early restenosis following biodegradable stent implantation in an aortopulmonary collateral of a patient with pulmonary atresia and hypoplastic pulmonary arteries
38. Preliminary results after application of absorbable metal stents in patients with critical limb ischemia10.1583/04-1349R.1 ↗
39. First clinical application of absorbable metal stents in the treatment of critical limb ischemia: 12-month results
40. AMS INSIGHT—Absorbable metal stent implantation for treatment of below-the-knee critical limb ischemia: 6-month analysis10.1007/s00270-008-9472-8 ↗
41. Biocorrodible metals for coronary revascularization: lessons from PROGRESS-AMS, BIOSOLVE-I, and BIOSOLVE-II10.5339/gcsp.2015.63 ↗
42. Clinical end points in coronary stent trials: a case for standardized definitions10.1161/CIRCULATIONAHA.106.685313 ↗
43. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial10.1016/S0140-6736(07)60853-8 ↗
44. Early-and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries
45. Safety and performance of the drug-eluting absorbable metal scaffold (DREAMS) in patients with de-novo coronary lesions: 12 month results of the prospective, multicentre, first-in-man BIOSOLVE-I trial10.1016/S0140-6736(12)61765-6 ↗
46. Safety and performance of the DRug-Eluting Absorbable Metal Scaffold (DREAMS) in patients with de novo coronary lesions: 3-year results of the prospective, multicentre, first-in-man BIOSOLVE-I trial10.4244/EIJ-D-15-00371 ↗
47. Safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de-novo coronary artery lesions (BIOSOLVE-II): 6 month results of a prospective, multicentre, non-randomised, first-in-man trial10.1016/S0140-6736(15)00447-X ↗
48. Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial10.1093/eurheartj/ehw196 ↗
49. In vivo serial invasive imaging of the second-generation drug-eluting absorbable metal scaffold (Magmaris—DREAMS 2G) in de novo coronary lesions: insights from the BIOSOLVE-II first-in-man trial10.1016/j.ijcard.2017.12.053 ↗
50. Safety and performance of the second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) in patients with de novo coronary lesions: three-year clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial10.4244/EIJ-D-18-01000 ↗
51. Safety and clinical performance of a drug eluting absorbable metal scaffold in the treatment of subjects with de novo lesions in native coronary arteries: pooled 12-month outcomes of BIOSOLVE-II and BIOSOLVE-III
52. Sustained safety and clinical performance of a drug-eluting absorbable metal scaffold up to 24 months: pooled outcomes of BIOSOLVE-II and BIOSOLVE-III10.4244/EIJ-D-17-00254 ↗
53. Drug-Eluting Resorbable Magnesium Scaffold Implantation in ST-Segment Elevation Myocardial Infarction: a Pilot Study
54. Magnesium-based resorbable scaffold versus permanent metallic sirolimus-eluting stent in patients with ST-segment elevation myocardial infarction: the MAGSTEMI randomized clinical trial10.1161/CIRCULATIONAHA.119.043467 ↗
55. BIOSOLVE-IV-registry: safety and performance of the Magmaris scaffold: 12-month outcomes of the first cohort of 1,075 patients
56. Sirolimus-eluting versus bare stents for bailout after suboptimal infrapopliteal angioplasty for critical limb ischemia: 6-month angiographic results from a nonrandomized prospective single-center study10.1583/05-1620MR.1 ↗
57. Comparison of sirolimus-eluting vs. bare-metal stents for the treatment of infrapopliteal obstructions
58. Initial evidence for the return of coronary vasoreactivity following the absorption of bioabsorbable magnesium alloy coronary stents10.4244/JV4I4A82 ↗
59. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization10.1056/NEJMoa012843 ↗
60. Enhanced efficacy of sirolimus-eluting bioabsorbable magnesium alloy stents in the prevention of restenosis10.1583/10-3353.1 ↗
61. Bioresorbable drug-eluting magnesium-alloy scaffold: design and feasibility in a porcine coronary model10.4244/EIJV8I12A218 ↗
62. Drug-eluting stent thrombosis in routine clinical practice: two-year outcomes and predictors from the TAXUS ARRIVE registries
63. Y.B. Juwana, S. Rasoul, J.P. Ottervanger, H. Suryapranata, Efficacy and safety of rapamycin as compared to paclitaxel-eluting stents: a meta-analysis, 2010.
64. Comparison of a novel biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: results of the randomized BIOFLOW-II trial
65. Mechanism of drug-eluting absorbable metal scaffold restenosis: a serial optical coherence tomography study
66. Comparison of clinical outcomes between Magmaris and Orsiro drug eluting stent at 12 months: pooled patient level analysis from BIOSOLVE II–III and BIOFLOW II trials10.1016/j.ijcard.2019.11.003 ↗
67. Bioresorbable scaffolds versus metallic stents in routine PCI10.1056/NEJMoa1614954 ↗
68. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimuseluting bioresorbable scaffold and an everolimus-eluting metallic stent: insights from the randomised ABSORB Japan trial10.4244/EIJY16M09_01 ↗
69. Randomised comparison of a bioresorbable everolimus-eluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions: the 2-year clinical outcomes of the ABSORB II trial10.4244/EIJY16M08_01 ↗
70. Device thrombosis with bioresorbable scaffolds
71. Sustained safety and performance of the second-generation sirolimus-eluting absorbable metal scaffold: pooled outcomes of the BIOSOLVE-II and-III trials at 3 years10.1016/j.carrev.2020.04.006 ↗
72. Second-generation drug-eluting resorbable magnesium scaffold: review of the clinical evidence10.1016/j.carrev.2019.10.012 ↗
73. Magmaris preliminary recommendation upon commercial launch: a consensus from the expert panel on 14 April 201610.4244/EIJV12I7A137 ↗
74. Comparison of clinical outcomes between magmaris (DREAMS 2G) and orsiro drug eluting stents: pooled patient level analysis from biosolve II-III and bioflow II trials10.1016/S0735-1097(18)31650-4 ↗
75. Serial invasive imaging follow-up of the first clinical experience with the Magmaris magnesium bioresorbable scaffold
76. Early restenosis of resorbable magnesium scaffolds: optical coherence tomography findings
77. Early collapse causing stenosis in a resorbable magnesium scaffold
78. MagmarisTM resorbable magnesium scaffold: state-of-art review10.2217/fca-2018-0081 ↗
79. High performance fine-grained biodegradable Mg-Zn-Ca alloys processed by severe plastic deformation10.3390/met9020186 ↗
80. Tailoring the mechanical and degradation performance of Mg-2.0Zn-0.5 Ca-0.4 Mn alloy through microstructure design
81. Microstructure and texture evolution of fine-grained Mg-Zn-Y-Nd alloy micro-tubes for biodegradable vascular stents processed by hot extrusion and rapid cooling10.1016/j.jma.2019.09.012 ↗
82. Enhanced plasticity of magnesium alloy micro-tubes for vascular stents by double extrusion with large plastic deformation10.1016/j.matlet.2019.02.114 ↗
83. Prospects and strategies for magnesium alloys as biodegradable implants from crystalline to bulk metallic glasses and composites—A review10.1016/j.actbio.2019.12.023 ↗
84. Laser microcutting of sheet metal for prototyping expandable stent-like structures in permanent and biodegradable alloys
85. Additive manufacturing of biodegradable metals: current research status and future perspectives10.1016/j.actbio.2019.04.046 ↗
86. Single track deposition study of biodegradable Mg-rare earth alloy by micro laser metal wire deposition
87. Selective laser melting of magnesium alloys, European congress and exhibition on powder metallurgy
88. Additive manufactured WE43 magnesium: a comparative study of the microstructure and mechanical properties with those of powder extruded and as-cast WE4310.1016/j.matchar.2018.11.011 ↗
89. Fundamentals and advances in magnesium alloy corrosion10.1016/j.pmatsci.2017.04.011 ↗
90. Mg-based bulk metallic glasses for biodegradable implant materials: a review on glass forming ability, mechanical properties, and biocompatibility10.1016/j.jnoncrysol.2015.07.018 ↗
91. Novel bioabsorbable polymer and polymer-free metallic drug-eluting stents10.1016/j.jjcc.2017.12.007 ↗
92. Coatings for biodegradable magnesium-based supports for therapy of vascular disease: a general view
93. Polymer-free drug-eluting stents: an overview of coating strategies and comparison with polymer-coated drug-eluting stents10.1021/acs.bioconjchem.5b00192 ↗
94. Some design considerations for polymer-free drug-eluting stents: a mathematical approach10.1016/j.actbio.2015.02.006 ↗
95. An asymmetric surface coating strategy for improved corrosion resistance and vascular compatibility of magnesium alloy stents10.1016/j.matdes.2020.109182 ↗
96. The blood compatibility challenge. Part 4: surface modification for hemocompatible materials: passive and active approaches to guide blood-material interactions10.1016/j.actbio.2019.06.019 ↗
97. Nano-micrometer surface roughness gradients reveal topographical influences on differentiating responses of vascular cells on biodegradable magnesium10.1016/j.bioactmat.2020.08.004 ↗
98. Strategies to develop endogenous stem cell-recruiting bioactive materials for tissue repair and regeneration10.1016/j.addr.2017.07.011 ↗
99. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal—Results 6–18 months after implantation into New Zealand white rabbits10.1136/heart.86.5.563 ↗
100. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗