journal article·2024-01

The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure

Agnieszka Chmielewska, David Dean

Acta Biomaterialia· Volume 173
Publisher page

Abstract

It is well documented that overly stiff skeletal replacement and fixation devices may fail and require revision surgery. Recent attempts to better support healing and sustain healed bone have looked at stiffness-matching of these devices to the desired role of limiting the stress on fractured or engrafted bone to compressive loads and, after the reconstructed bone has healed, to ensure that reconstructive medical devices (implants) interrupt the normal loading pattern as little as possible. The mechanical performance of these devices can be optimized by adjusting their location, integration/fastening, material(s), geometry (external and internal), and surface properties. This review highlights recent research that focuses on the optimal design of skeletal reconstruction devices to perform during and after healing as the mechanical regime changes. Previous studies have considered auxetic materials, homogeneous or gradient (i.e., adaptive) porosity, surface modification to enhance device/bone integration, and choosing the device's attachment location to ensure good osseointegration and resilient load transduction. By combining some or all of these factors, device designers work hard to avoid problems brought about by unsustainable stress shielding or stress concentrations as a means of creating sustainable stress-strain relationships that best repair and sustain a surgically reconstructed skeletal site. STATEMENT OF SIGNIFICANCE: Although standard-of-care skeletal reconstruction devices will usually allow normal healing and improved comfort for the patient during normal activities, there may be significant disadvantages during long-term use. Stress shielding and stress concentration are amongst the most common causes of failure of a metallic device. This review highlights recent developments in devices for skeletal reconstruction that match the stiffness, while not interrupting the normal loading pattern of a healthy bone, and help to combat stress shielding and stress concentration. This review summarises various approaches to achieve stiffness-matching: application of materials with modulus close to that of the bone; adaptation of geometry with pre-defined mechanical properties; and/or surface modification that ensures good integration and proper load transfer to the bone.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Cellular and Composite Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. 2018
2. 2022
3. Biomaterial types, properties, medical applications, and other factors: a recent review10.1631/jzus.A2200403 ↗
4. Titanium spinal-fixation implants
5. The chemistry of inorganic biomaterials
6. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications10.1016/j.msec.2019.04.064 ↗
7. Surface modified NiTi smart biomaterials: surface engineering and biological compatibility
8. Metals for bone implants: safety, design, and efficacy10.1007/s40898-016-0001-2 ↗
9. Orthopedic implants and devices for bone fractures and defects: past, present and perspective
10. Re-thinking the bone remodeling cycle mechanism and the origin of bone loss10.1016/j.bone.2020.115628 ↗
11. When the total hip replacement fails: a review on the stress-shielding effect10.3390/pr10030612 ↗
12. On fatigue failure prediction of prosthetic devices through XFEM analysis10.1016/j.ijfatigue.2021.106160 ↗
13. Reducing stress concentration on the cup rim of hip implants under edge loading10.1002/cnm.3149 ↗
14. Influence of sagittal root positions on the stress distribution around custom-made root-analogue implants: a three-dimensional finite element analysis10.1186/s12903-021-01809-4 ↗
15. Host response to orthopedic implants (Metals and Plastics)
16. Repair of skeletal tissues
17. Bone anatomy, physiology and adaptation to mechanical loading
18. Failure mechanisms in joint replacement
19. Conception of osseointegration in development of orthopedic implant industry
20. Metals for bone implants. Part 1. Powder metallurgy and implant rendering10.1016/j.actbio.2014.06.025 ↗
21. Stress shielding in periprosthetic bone following a total knee replacement: effects of implant material, design and alignment10.1016/j.medengphy.2016.09.018 ↗
22. Porous architected biomaterial for a tibial-knee implant with minimum bone resorption and bone-implant interface micromotion10.1016/j.jmbbm.2017.11.041 ↗
23. Medial tibial stress shielding: a limitation of cobalt chromium tibial baseplates10.1016/j.arth.2016.07.027 ↗
24. Stress shielding and bone resorption in shoulder arthroplasty10.1067/mse.2003.22 ↗
25. The effect of spinal implant rigidity on vertebral10.1097/00007632-199106001-00003 ↗
26. Long-term implant fixation and stress-shielding in total hip replacement10.1016/j.jbiomech.2014.12.021 ↗
27. Benefits of hardware removal after plating10.1016/S0020-1383(18)30311-5 ↗
28. Plate failure by bending following tibial fracture stabilisation in 10 cats10.1111/jsap.12532 ↗
29. Reconstruction using a free vascularized fibular graft after frozen autograft reconstruction for osteosarcoma of the distal tibia: a case report10.4236/mps.2013.31009 ↗
30. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
31. Functionally graded materials for orthopedic applications – an update on design and manufacturing10.1016/j.biotechadv.2015.12.013 ↗
32. Achieving biocompatible stiffness in NiTi through additive manufacturing10.1177/1045389X16641199 ↗
33. Risk factors for refracture after plate removal for midshaft clavicle fracture after bone union10.1186/s13018-019-1516-z ↗
34. Removal of symptomatic craniofacial titanium hardware following craniotomy: case series and review10.1016/j.inat.2015.04.002 ↗
35. Numerical simulation of callus healing for optimization of fracture fixation stiffness10.1371/journal.pone.0101370 ↗
36. Isolated and modulated effects of topology and material type on the mechanical properties of additively manufactured porous biomaterials10.1016/j.jmbbm.2017.12.029 ↗
37. Variable fixation promotes callus formation: an experimental study on transverse tibial osteotomies stabilized with locking plates10.1186/s12891-020-03781-6 ↗
38. Shear movement at the fracture site delays healing in a diaphyseal fracture model10.1016/S0736-0266(03)00098-6 ↗
39. Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: a new approach?10.1016/j.jcms.2017.01.025 ↗
40. Fatigue performance of additively manufactured meta-biomaterials: the effects of topology and material type10.1016/j.actbio.2017.11.014 ↗
41. Effect of interfragmentary gap on the mechanical behavior of mandibular angle fracture with three fixation designs: a finite element analysis10.1016/j.bjps.2016.10.026 ↗
42. Topology optimization of mandible fracture plate
43. The design of additively manufactured lattices to increase the functionality of medical implants10.1016/j.msec.2018.10.052 ↗
44. Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: a review10.1016/j.biomaterials.2016.01.012 ↗
45. Implementation of advanced design and additive manufacturing techniques for the development of medical-relevant devices
46. Mechanical evaluation of the SLM fabricated, stiffness-matched, mandibular bone fixation plates
47. Design, modeling, additive manufacturing, and polishing of stiffness-modulated porous nitinol bone fixation plates followed by thermomechanical and composition analysis10.3390/met10010151 ↗
48. Fixation release and the bone bandaid: a new bone fixation device paradigm10.3390/bioengineering4010005 ↗
49. Three dimensional printing of stiffness-tuned, nitinol skeletal fixation hardware with an example of mandibular segmental defect repair10.1016/j.procir.2015.07.027 ↗
50. Mechanical regulation of bone remodeling10.1038/s41413-022-00190-4 ↗
51. Workflow for robotic point-of-care manufacturing of personalized maxillofacial graft fixation hardware10.1007/s40192-023-00298-3 ↗
52. Effect of the material's stiffness on stress-shielding in osseointegrated implants for bone-anchored prostheses: a numerical analysis and initial benchmark data10.37190/ABB-01543-2020-02 ↗
53. Assessment of compression and strength of divergent screws mounted on miniplates and dynamic compression plate in fixation of mandibular body fractures: an in vitro study10.1016/j.bjoms.2020.07.021 ↗
54. The biologic effects of implant materials10.1002/jor.1100090516 ↗
55. Yahia · 2000
56. An overview of nitinol medical applications10.1016/S0921-5093(99)00294-4 ↗
57. Microstructure and mechanical properties of a novel β titanium metallic composite by selective laser melting10.1016/j.actamat.2014.01.018 ↗
58. Chenlin · 2002 · 6409852
59. Bone formation at the surface of low modulus Ti-7.5Mo implants in rabbit femur10.1016/j.biomaterials.2007.02.005 ↗
60. New developments of ti-based alloys for biomedical applications10.3390/ma7031709 ↗
61. 2013
62. 2008
63. Selective laser melting of Ti-45Nb alloy10.3390/met5020686 ↗
64. Enhancement of mechanical properties of biocompatible Ti-45Nb alloy by hydrostatic extrusion10.1007/s10853-014-8397-7 ↗
65. Processing a biocompatible Ti-35Nb-7Zr-5Ta alloy by selective laser melting10.1557/jmr.2020.90 ↗
66. Characterization of Ti-35Nb-7Zr-5Ta alloy produced by powder metallurgy10.4028/www.scientific.net/MSF.498-499.34 ↗
67. Super multifunctional alloy “GUM METAL”
68. Multifunctional alloys obtained via a dislocation-free plastic deformation mechanism
69. Compositional variability in gum metal10.1016/j.scriptamat.2009.02.044 ↗
70. A review on NiTi alloys for biomedical applications and their biocompatibility
71. Nanocavitation of stainless steel improves its corrosion resistance and minimizes toxic effects on MC3T3-E1 osteogenic cells10.1016/j.surfcoat.2019.125225 ↗
72. Vanadium ionic species from degradation of Ti-6Al-4V metallic implants: in vitro cytotoxicity and seciation evaluation10.1016/j.msec.2018.11.090 ↗
73. Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening - current concepts10.1002/jbm.a.32625 ↗
74. S.-F. Ou, B.-Y. Peng, Y.-C. Chen, M.-H. Tsai, Manufacturing and characterization of NiTi alloy with functional properties by selective laser melting, Metals. 8 (2018) 342. 10.3390/met8050342.10.3390/met8050342 ↗
75. The story of nitinol: the serendipitous discovery of the memory metal and its applications10.1007/s000897970155a ↗
76. History and current situation of shape memory alloys devices for minimally invasive surgery10.2174/1875181401002020024 ↗
77. Nitinol: from historical milestones to functional properties and biomedical applications10.1177/09544119221123176 ↗
78. Improved osteogenic activity of NiTi orthopedic implant by HAp-Nb2O5 composite coatings: materials and biological points of view10.1016/j.bioadv.2023.213435 ↗
79. Additive manufacturing: an opportunity for the fabrication of near-net-shape NiTi implants
80. Chemical polishing of additively manufactured, porous, nickel–titanium skeletal fixation plates
81. The biocompatibility of dense and porous Nickel-Titanium produced by selective laser melting10.1016/j.msec.2012.09.008 ↗
82. Biocompatibility of NiTi
83. Improving corrosion resistance of additively manufactured nickel–titanium biomedical devices by micro-arc oxidation process10.1007/s10853-019-03375-1 ↗
84. Biological and corrosion evaluation of in situ alloyed NiTi fabricated through laser powder bed fusion (LPBF)10.3390/ijms222413209 ↗
85. Biocompatibility of a novel heat-treated and ceramic-coated magnesium alloy (Mg-1.2Zn-0.5Ca-0.5Mn) for resorbable skeletal fixation devices10.1557/mrc.2020.46 ↗
86. Corrosion and biocompatibility assessment of magnesium alloys10.4236/jbnb.2012.31002 ↗
87. Microstructural, mechanical and corrosion characteristics of heat-treated Mg-1.2Zn-0.5Ca (wt%) alloy for use as resorbable bone fixation material10.1016/j.jmbbm.2017.01.005 ↗
88. Resorbable bone fixation alloys, forming, and post-fabrication treatments10.1016/j.msec.2016.09.069 ↗
89. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review10.1016/j.pmatsci.2008.06.004 ↗
90. Recent developments in coatings for orthopedic metallic implants
91. Titanium for orthopedic applications: an overview of surface modification to improve biocompatibility and prevent bacterial biofilm formation10.1016/j.isci.2020.101745 ↗
92. Microstructure, mechanical and corrosion properties of biodegradable powder metallurgical Fe-2 wt% X (X = Pd, Ag and C) alloys10.1016/j.matchemphys.2016.06.087 ↗
93. Biodegradable Fe-based alloys for use in osteosynthesis: outcome of an in vivo study after 52 weeks10.1016/j.actbio.2014.04.007 ↗
94. Study of corrosion in biocompatible metals for implants: a review10.1016/j.jallcom.2017.01.196 ↗
95. Ultra-high-molecular-weight-polyethylene (UHMWPE) as a promising polymer material for biomedical applications: a concise review10.3390/polym12020323 ↗
96. Bulge micro-textures influence on tribological performance of Ultra-High-Molecular-Weight-Polyethylene (UHMWPE) under Phosphatidylcholine (Lipid) and Bovine Serum Albumin (BSA) solutions10.1088/2057-1976/ab0e94 ↗
97. Influence of laser processing conditions for texturing on ultra-high-molecular-weight-polyethylene (UHMWPE) surface10.1016/j.csite.2019.100491 ↗
98. Development and characterization of zirconia–alumina composites for orthopedic implants10.1016/j.ceramint.2016.09.216 ↗
99. Zirconia-alumina composite for orthopedic implant application
100. Osteoblast adhesion on biomaterials10.1016/S0142-9612(99)00242-2 ↗