The mechanical and electrical properties of polycaprolactone fumarate-polypyrrole (PCLF-PPy) scaffolds were studied under physiological conditions to evaluate their ability to maintain the material properties necessary for application as conductive nerve conduits. PC12 cells cultured on PCLF-PPy scaffolds were stimulated with regimens of 10 μA of either a constant or a 20 Hz frequency current passed through the scaffolds for 1h per day. PC12 cellular morphologies were analyzed by fluorescence microscopy after 48 h. PCLF-PPy scaffolds exhibited excellent mechanical properties at 37 °C which would allow suturing and flexibility. The surface resistivity of the scaffolds was 2 kΩ and the scaffolds were electrically stable during the application of electrical stimulation (ES). In vitro studies showed significant increases in the percentage of neurite bearing cells, number of neurites per cell and neurite length in the presence of ES compared with no ES. Additionally, extending neurites were observed to align in the direction of the applied current. This study shows that electrically conductive PCLF-PPy scaffolds possess the material properties necessary for application as nerve conduits. Additionally, the capability to significantly enhance and direct neurite extension by passing an electrical current through PCLF-PPy scaffolds renders them even more promising as future therapeutic treatments for severe nerve injuries.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Conducting polymers and applications · Neuroscience and Neural Engineering · Advanced Sensor and Energy Harvesting Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (62)

Show source-provided references
1. Treatment of acute peripheral nerve injuries: current concepts10.1016/j.jhsa.2009.12.009 ↗
2. Brief electrical stimulation promotes the speed and accuracy of motor axonal regeneration10.1523/JNEUROSCI.20-07-02602.2000 ↗
4. Polyester based nerve guidance conduit design10.1016/j.biomaterials.2009.11.013 ↗
5. Chiono V, Vozzi G, Vozzi F, Salvadori C, Dini F, Carlucci F, et al. Melt-extruded guides for peripheral nerve regeneration. Part I. Poly(epsilon-caprolactone). Biomed Microdevices 2009;May:Epub.10.1007/s10544-009-9321-9 ↗
6. Collagen nerve conduits promote enhanced axonal regeneration, Schwann cell association, and neovascularization compared to silicone conduits10.1089/ten.tea.2008.0338 ↗
7. Methods for in vitro characterization of multichannel nerve tubes
8. Accuracy of motor axon regeneration across autograft, single-lumen, and multichannel poly(lactic–co-glycolic acid) nerve tubes10.1227/01.NEU.0000319521.28683.75 ↗
9. Misdirection of regenerating motor axons after nerve injury and repair in the rat sciatic nerve model10.1016/j.expneurol.2007.12.023 ↗
10. Multiple-channel scaffolds to promote spinal cord axon regeneration10.1016/j.biomaterials.2005.07.045 ↗
11. Photo-crosslinked poly(ε-caprolactone fumarate) networks for guided peripheral nerve regeneration: material properties and preliminary biological evaluations10.1016/j.actbio.2008.12.015 ↗
12. Synthesis and characterizations of biodegradable and crosslinkable poly(ε-caprolactone fumarate), poly(ethylene glycol fumarate), and their amphiphilic copolymer10.1016/j.biomaterials.2005.07.013 ↗
13. Characteristics of PLGA–gelatin complex as potential artificial nerve scaffold10.1016/j.colsurfb.2007.02.010 ↗
14. In vitro and in vivo testing of novel ultrathin PCL and PCL/PLA blend films as peripheral nerve conduit10.1002/jbm.a.32681 ↗
15. Collagen nerve conduits releasing the neurotrophic factors GDNF and NGF10.1016/j.jconrel.2009.12.017 ↗
16. Trophically and topographically functionalized silk fibroin nerve conduits for guided peripheral nerve regeneration10.1016/j.biomaterials.2009.11.073 ↗
17. Variations in glial cell line-derived neurotrophic factor release from biodegradable nerve conduits modify the rate of functional motor recovery after rat primary nerve repairs10.1111/j.1460-9568.2007.05748.x ↗
18. Electrical stimulation promotes motoneuron regeneration without increasing its speed or conditioning the neuron10.1523/JNEUROSCI.22-15-06631.2002 ↗
19. Brief electrical stimulation accelerates axon regeneration in the peripheral nervous system and promotes sensory axon regeneration in the central nervous system10.1123/mcj.13.4.412 ↗
20. Electrical stimulation promotes sensory neuron regeneration and growth-associated gene expression10.1016/j.expneurol.2007.01.040 ↗
21. Polypyrrole-based conducting polymers and interactions with biological tissues10.1098/rsif.2006.0141 ↗
22. Template synthesis of the polypyrrole tube and its bridging in vivo sciatic nerve regeneration10.1023/A:1026799415199 ↗
23. Micropatterned polypyrrole: a combination of electrical and topographical characteristics for the stimulation of cells10.1002/adfm.200600669 ↗
24. Nerve growth factor-immobilized polypyrrole: bioactive electrically conducting polymer for enhanced neurite extension10.1002/jbm.a.31047 ↗
25. Carboxylic acid-functionalized conductive polypyrrole as a bioactive platform for cell adhesion10.1021/bm060220q ↗
26. Carboxy-endcapped conductive polypyrrole: biomimetic conducting polymer for cell scaffolds and electrodes10.1021/la062129d ↗
27. New biocompatible polypyrrole-based films with good blood compatibility and high electrical conductivity10.1016/j.colsurfb.2008.07.012 ↗
28. Structure and degradation behavior of polypyrrole doped with sulfonate anions and different sizes subject to undoping–redoping cycles10.1021/cm950312e ↗
29. Tissue spinal cord response in rats after implants of polypyrrole and polyethylene glycol obtained by plasma10.1007/s10856-007-3080-z ↗
30. The regulation of cell functions electrically using biodegradable polypyrrole–polylactide conductors10.1016/j.biomaterials.2008.06.010 ↗
31. A novel electrochemically synthesized biodegradable thin film of polypyrrole–polyethyleneglycol–polylactic acid nanoparticles10.1039/B611700G ↗
32. Evaluation of biocompatibility of polypyrrole in vitro and in vivo
33. Polypyrrole-coated electrospun PLGA nanofibers for neural tissue applications10.1016/j.biomaterials.2009.04.042 ↗
34. A novel electrically conductive and biodegradable composite made of polypyrrole nanoparticles and polylactide10.1016/j.biomaterials.2003.09.032 ↗
35. Multiwall carbon nanotube scaffolds for tissue engineering purposes10.1016/j.biomaterials.2007.09.021 ↗
36. Tubular micro-scale multiwalled carbon nanotube-based scaffolds for tissue engineering10.1016/j.biomaterials.2008.12.031 ↗
37. Electrical pulsed stimulation of surfaces homogeneously coated with gold nanoparticles to induce neurite outgrowth of PC12 cells10.1021/la8025683 ↗
38. Conducting polymers in biomedical engineering10.1016/j.progpolymsci.2007.05.012 ↗
39. The development of electrically conductive polycaprolactone fumarate–polypyrrole composite materials for nerve regeneration10.1016/j.biomaterials.2010.04.012 ↗
40. Novel Degradable co-polymers of polypyrrole support cell proliferation and enhance neurite out-growth with electrical stimulation10.1163/092050609X12481751806330 ↗
41. Electrical regulation of Schwann cells using conductive polypyrrole/chitosan polymers10.1002/jbm.a.32511 ↗
42. Effect of functionalized micropatterned PLGA on guided neurite growth10.1016/j.actbio.2008.09.002 ↗
43. Photo-cross-linked hybrid polymer networks consisting of poly(propylene fumarate) and poly(caprolactone fumarate): controlled physical properties and regulated bone and nerve cell responses10.1021/bm7012313 ↗
44. Neurite outgrowth and branching of PC12 cells on very soft substrates sharply decreases below a threshold of substrate rigidity10.1088/1741-2560/4/2/003 ↗
45. Photo-crosslinked poly(ε-caprolactone fumarate) networks: roles of crystallinity and crosslinking density in determining mechanical properties10.1016/j.polymer.2008.10.021 ↗
46. Designing ideal conduits for peripheral nerve repair10.3171/FOC.2009.26.2.E5 ↗
47. Biological performance of a degradable poly(lactic acid–epsilon-caprolactone) nerve guide: influence of tube dimensions10.1002/jbm.820290612 ↗
48. Electrically conductive biodegradable polymer composite for nerve regeneration: electricity-stimulated neurite outgrowth and axon regeneration10.1111/j.1525-1594.2007.00335.x ↗
49. Augmenting nerve regeneration with electrical stimulation10.1179/174313208X362488 ↗
50. Accelerating axon growth to overcome limitations in functional recovery after peripheral nerve injury10.1227/01.NEU.0000335650.09473.D3 ↗
51. One hour electrical stimulation accelerates functional recovery after femoral nerve repair10.1016/j.expneurol.2007.08.005 ↗
52. Stimulation of neurite outgrowth using an electrically conductive polymer10.1073/pnas.94.17.8948 ↗
53. Electrical stimulation alters protein adsorption and nerve cell interactions with electrically conducting biomaterials10.1016/S0142-9612(00)00344-6 ↗
54. Perturbation of the direction of neurite growth by pulsed and focal electric fields10.1523/JNEUROSCI.04-12-02939.1984 ↗
55. Orientation of neurite growth by extracellular electric fields10.1523/JNEUROSCI.02-04-00483.1982 ↗
56. Enhanced neurite alignment on micro-patterned poly-l-lactic acid films10.1002/jbm.a.31814 ↗
57. The influence of microchannels on neurite growth and architecture10.1016/j.biomaterials.2004.03.015 ↗
58. Aligned electrospun nanofibers specify the direction of dorsal root ganglia neurite growth10.1002/jbm.a.31285 ↗
59. Guidance of glial cell migration and axonal growth on electrospun nanofibers of poly-epsilon-caprolactone and a collagen/poly-epsilon-caprolactone blend10.1016/j.biomaterials.2007.03.009 ↗
60. Growth cone neurotransmitter receptor activation modulates electric field-guided nerve growth10.1006/dbio.1995.1285 ↗
61. Hippocampal growth cone responses to focally applied electric fields10.1002/neu.480240108 ↗
62. The growth of PC12 neurites is biased towards the anode of an applied electrical field10.1002/neu.480251204 ↗