journal article·2026-03-04Open access

Cross-laminated timber: a state-of-the-art review of moisture, fire, acoustics, and energy-related aspects

Fredrik Ljunggren, Maria Fredriksson, Nils Johansson, Angela Sasic Kalagasidis

Abstract

The increasing use of cross-laminated timber (CLT) in construction has encouraged research on moisture, fire, acoustics, and energy performance. These areas are crucial for CLT buildings’ functionality and durability and are typically addressed together during design. This study reviewed current knowledge, identifies gaps and explores synergies and conflicts among these areas, while briefly addressing the environmental impact of CLT buildings. Key findings include that airtightness is critical but often overlooked, making field and lab measurements essential. Junctions between CLT elements pose challenges in modeling sound and vibration transfer, and water absorption and removal, necessitating further research on junction robustness. More attention should be given to CLT's limited thermal mass and its impact on overheating risks, cooling demands, and fire development. Enhanced ventilation has a limited impact on off-gassing of volatile organic compounds. Covering CLT panels may be beneficial for energy efficiency, fire safety, and acoustics. Environmental impact assessments of buildings are complex and often neglect operational technical aspects. The aspects identified here are crucial for extending the service life of CLT buildings and enabling the reuse of CLT elements in circular economy value chains. Methodological innovations are needed to enhance evaluation flexibility across entire value chains.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Natural Fiber Reinforced Composites · Hygrothermal properties of building materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Luleå University of Technology

Lund University

Chalmers University of Technology

Funding

Swedish Universities of the Built Environment

References (100+)

Show source-provided references
1. Aguanno, M., Hadjisophocleous, G., and Craft, S., 2013. Fire resistance tests on cross-laminated timber floor panels. In: Fire and materials 2013 - 13th International Conference and Exhibition. San Francisco, USA, 197–208.
2. 10.3390/ma1622715310.3390/ma16227153 ↗
3. 10.1016/j.rser.2016.09.05810.1016/j.rser.2016.09.058 ↗
4. ANSI/APA American National Standard 2018. Standard for performance-rated cross-laminated timber.
5. 10.1002/ieam.173510.1002/ieam.1735 ↗
6. 10.1080/17480272.2020.180183510.1080/17480272.2020.1801835 ↗
7. 10.1016/j.jobe.2021.10373110.1016/j.jobe.2021.103731 ↗
8. 10.1186/s10086-022-02041-610.1186/s10086-022-02041-6 ↗
9. 10.1016/j.buildenv.2021.10811210.1016/j.buildenv.2021.108112 ↗
10. Barber, D., et al., 2021. Medium scale fire testing of cross laminated timber with non-delaminating adhesive. Santiago, Chile: WCTE 2021 World Conference on Timber Engineering.
11. Barber, D., Crielaard, R., and Li, X., 2016. Towards fire safe design of exposed timber in tall timber buildings. In: WCTE 2016 - World Conference on Timber Engineering. Vienna, Austria, 3936–3945.
12. Bartlett A. et al. 2015a. Fire-induced delamination of cross-laminated timber. 1st European Workshop Fire Safety of Green Buildings p. 17–20.
13. Bartlett, A.I., et al., 2015b. Analysis of cross-laminated timber charring rates upon exposure to nonstandard heating conditions. In: Fire and materials 2015 - 14th international conference and exhibition, proceedings. San Francisco, USA, 667–681.
14. Beresford T. and Chen J. 2019. Floor airborne and impact sound insulation performance of cross laminated timber vs. timber joist and concrete systems. Australian Acoustical Society Annual Conference AAS 2018:122–30.
15. 10.3390/app1113593810.3390/app11135938 ↗
16. 10.1016/j.firesaf.2023.10398610.1016/j.firesaf.2023.103986 ↗
17. 10.1016/j.firesaf.2023.10386910.1016/j.firesaf.2023.103869 ↗
18. 10.1007/s00107-015-0999-510.1007/s00107-015-0999-5 ↗
19. Brandon, D. and Dagenais, C., 2018. Fire safety challenges of tall wood buildings – Phase 2: Task 5 – Experimental study of delamination of cross laminated timber (CLT) in fire. Quincy, USA: National Fire Protection Association (NFPA), Report number: FPRF-2018-05.
20. Brandon, D. and Östman, B., 2016. Fire safety challenges of tall wood buildings – Phase 2: Task 1 - Literature review. Quincy, USA: National Fire Protection Association (NFPA).
21. 10.1016/j.jobe.2023.10809710.1016/j.jobe.2023.108097 ↗
22. 10.1007/s00253-020-10479-110.1007/s00253-020-10479-1 ↗
23. 10.1016/j.apenergy.2018.12.03510.1016/j.apenergy.2018.12.035 ↗
24. 10.1016/j.matdes.2023.11196710.1016/j.matdes.2023.111967 ↗
25. 10.3390/ma1408184810.3390/ma14081848 ↗
26. Calderón A.F.B. 2022. Fire resilience of cross laminated timber in residential buildings. MSc thesis. Politecnico di Torino.
27. 10.1016/J.CONBUILDMAT.2021.12630310.1016/J.CONBUILDMAT.2021.126303 ↗
28. 10.18154/rwth-conv-23983110.18154/rwth-conv-239831 ↗
29. 10.1080/17480272.2020.172080410.1080/17480272.2020.1720804 ↗
30. Cato O. 2022. Fire resistance test of cross laminated timber joints. BSc thesis. Luleå University of Technology.
31. CEN, 2004. Eurocode 5: Design of timber structures - Part 1–2: General - structural fire design. Brussels: European Committee for Standardization.
32. 10.1016/j.buildenv.2019.10650210.1016/j.buildenv.2019.106502 ↗
33. 10.1016/j.conbuildmat.2019.04.00910.1016/j.conbuildmat.2019.04.009 ↗
34. 10.3390/su1211470810.3390/su12114708 ↗
35. 10.1016/j.conbuildmat.2019.08.01310.1016/j.conbuildmat.2019.08.013 ↗
36. 10.1016/j.enbuild.2019.07.04610.1016/j.enbuild.2019.07.046 ↗
37. 10.1016/j.jclepro.2019.05.19710.1016/j.jclepro.2019.05.197 ↗
38. 10.52202/069179-023610.52202/069179-0236 ↗
39. 10.1016/j.apacoust.2023.10927710.1016/j.apacoust.2023.109277 ↗
40. 10.1038/s41893-019-0462-410.1038/s41893-019-0462-4 ↗
41. 10.13140/rg.2.2.10704.8448010.13140/rg.2.2.10704.84480 ↗
42. 10.14264/a067f6310.14264/a067f63 ↗
43. 10.1201/9780429343292-11910.1201/9780429343292-119 ↗
44. Craft, S., et al., 2018. Test methods to evaluate the adhesive performance in CLT when exposed to fire. Seoul, South Korea: WCTE.
45. 10.1016/j.firesaf.2019.01.00810.1016/j.firesaf.2019.01.008 ↗
46. 10.1016/j.firesaf.2023.10393710.1016/j.firesaf.2023.103937 ↗
47. Dagenais C. 2015. Fire performance of cross-laminated timber panel-to-panel joints.
48. Dagenais C. 2016. Assessing the fire integrity performance of cross-laminated timber floor panel-to-panel joints. PhD thesis. Carleton University.
49. 10.3390/buildings1207097910.3390/buildings12070979 ↗
50. 10.1016/j.jsv.2022.11685110.1016/j.jsv.2022.116851 ↗
51. Di Bella A. et al. 2019. Flanking transmission in CLT buildings: Comparison between vibration reduction index measurements for different mounting conditions. Internoise SOCIEDAD ESPANOLA DE ACUSTICA - Spanish Acoustical Society SEA.
52. 10.3390/su1214561210.3390/su12145612 ↗
53. Di Nocco, F., et al., 2020. Use of the ISO 12354 standard for the prediction of the sound insulation of timber buildings: Application to three case studies. Building Simulation Applications, 2020-June, 141–147.
54. 10.1016/J.BUILDENV.2023.11033710.1016/J.BUILDENV.2023.110337 ↗
55. 10.1021/acs.est.3c0981510.1021/acs.est.3c09815 ↗
56. 10.3390/app905085810.3390/app9050858 ↗
57. 10.1016/j.enbuild.2025.11561010.1016/j.enbuild.2025.115610 ↗
58. 10.1002/978111997546510.1002/9781119975465 ↗
59. 10.1016/j.buildenv.2022.10932010.1016/j.buildenv.2022.109320 ↗
60. Emberley R. 2017. Fundamentals for the fire design of cross laminated timber buildings. PhD thesis. The University of Queensland.
61. 10.1016/j.firesaf.2017.03.00810.1016/j.firesaf.2017.03.008 ↗
62. 10.1016/j.firesaf.2017.03.02410.1016/j.firesaf.2017.03.024 ↗
63. Espinoza, O., et al., 2016. Cross-Laminated Timber: Status and Research Needs in Europe. Bioresources, 11, 281–295.
64. 10.1016/j.enbuild.2023.11355710.1016/j.enbuild.2023.113557 ↗
65. FPInnovations, 2019. Canadian CLT Handbook. vol. 1. Pointe-Claire, QC: FPInnovations.
66. 10.1016/j.firesaf.2009.07.00710.1016/j.firesaf.2009.07.007 ↗
67. 10.1016/J.ENGSTRUCT.2023.11666910.1016/J.ENGSTRUCT.2023.116669 ↗
68. 10.1002/fam.311010.1002/fam.3110 ↗
69. Global Alliance for Buildings and Construction 2019. 2019 Global status report for buildings and construction: Towards a zero-emission efficient and resilient buildings and construction sector.
70. Gorska C. Hidalgo J.P. and Torero J.L. 2017. An experimental study of medium-scale compartment fire tests with exposed cross laminated timber. International Fire Safety Symposium Proceedings of 2nd International Fire Safety Symposium p. 773–80.
71. 10.1016/J.FIRESAF.2020.10309810.1016/J.FIRESAF.2020.103098 ↗
72. Gorska Putynska, C., Law, A., and Torero-Cullen, J., 2017. An investigation into the effect of exposed timber on thermal load. Mechanics of Structures and Materials, XXIV, 939–944.
73. 10.3390/app1207323310.3390/app12073233 ↗
74. 10.3390/BUILDINGS1308193510.3390/BUILDINGS13081935 ↗
75. 10.3390/su902029210.3390/su9020292 ↗
76. 10.3390/en1323630510.3390/en13236305 ↗
77. 10.3390/app1005158210.3390/app10051582 ↗
78. 10.1016/j.firesaf.2017.03.07410.1016/j.firesaf.2017.03.074 ↗
79. 10.1016/j.jclepro.2017.04.05210.1016/j.jclepro.2017.04.052 ↗
80. Hameury S. 2006. The hygrothermal inertia of massive timber connstructions.
81. 10.1111/jiec.1313910.1111/jiec.13139 ↗
82. 10.1016/j.enbuild.2023.11346210.1016/j.enbuild.2023.113462 ↗
83. 10.1051/e3sconf/202017210.1051/e3sconf/2020172 ↗
84. Heselden, A.J., 1961. Some fires in a single compartment with independent variation of fuel surface area and thickness. Fire Research Note, 469. Boreham Wood, UK: Fire Research Station.
85. Hiramitsu, A., Tsuchimoto, T., and Kurumada, S., 2019. Influence of floor finish structure on floor impact sound insulation in CLT model building. Madrid, Spain: Internoise, SOCIEDAD ESPANOLA DE ACUSTICA - Spanish Acoustical Society, SEA.
86. Hoehler, M.S., et al., 2018. Fire safety challenges of tall wood buildings: Large-scale cross-laminated timber compartment fire tests. Belfast, UK: SiF, p. 396.
87. 10.1177/1351010X1668296610.1177/1351010X16682966 ↗
88. 10.3390/fire502003910.3390/fire5020039 ↗
89. 10.52202/069179-024210.52202/069179-0242 ↗
90. Hu, L., et al., 2020. Key parameters for impact and airborne noise control in wood buildings. Internoise, Korean Society of Noise and Vibration Engineering.
91. 10.1080/17480272.2020.171274010.1080/17480272.2020.1712740 ↗
92. 10.3390/fire609035210.3390/fire6090352 ↗
93. 10.3390/F1501003110.3390/F15010031 ↗
94. 10.1617/s11527-012-9965-410.1617/s11527-012-9965-4 ↗
95. ISO 12354-1:2017 2017a. Building Acoustics—Estimation of Acoustic Performance of Buildings from the Performance of Elements—Part 1: Airborne Sound Insulation Between Rooms.
96. ISO 12354-2:2017 2017b. Building Acoustics—Estimation of Acoustic Performance of Buildings from the Performance of Elements—Part 2: Impact Sound Insulation Between Rooms.
97. 10.3390/en1602058610.3390/en16020586 ↗
98. 10.1080/24751448.2020.180476310.1080/24751448.2020.1804763 ↗
99. 10.1016/J.CONBUILDMAT.2024.13849610.1016/J.CONBUILDMAT.2024.138496 ↗
100. 10.1007/s00107-023-02033-310.1007/s00107-023-02033-3 ↗