journal article·2025-01-02

Experimental evaluation of combustion performance in the three main anatomical sections of poplar wood

Fangya Pan, Zhilin Chen, Yuxiang Huang, Jiulong Xie, Hongyu Jia, Peng Jiang

Publisher page

Abstract

The interrelationship and organization between the axial and transversal systems gives rise to three main views, namely cross, radial and tangential sections. This study investigated the differences in combustion properties of the three main anatomical sections of poplar wood and explains the reasons for the differences regarding wood microstructure, pore structure, heat conduction, and microstructure after heat treatment. The thermal conductivity of poplar wood in the cross-section (Wood-CS) was 0.1864 W/m. K, exceeding those of the radial (Wood-RS) and tangential sections (Wood-TS) by 47% and 38%, respectively. In the cone calorimeter test (CC), the peak heat-release rate (pHRR) of Wood-CS samples was 92% and 73% higher than those of the Wood-RS and Wood-TS samples, respectively. This is attributed to the differences in microstructures and the occurrence of macropores in different anatomical sections. This study explored the combustion performance and mechanisms of wood samples in the three main sections, providing crucial theoretical insights for flame retardant impregnation levels in treating wood and aiding in the selection of fire-resistant wood-based building materials.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Fire effects on ecosystems · Lignin and Wood Chemistry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Research Institute of Wood Industry

Nanjing Forestry University

Sichuan Agricultural University

Funding

National Natural Science Foundation of China · the National Natural Science Foundation of China · Technology -based SME Innovation Capability Project

References (31)

Show source-provided references
1. 10.1002/fam.294710.1002/fam.2947 ↗
2. ASTM, 2017. E1354-17 standard test method for heat and visible smoke release rates for materials and products using an oxygen consumption calorimeter. West Conshohocken, PA: ASTM International.
3. 10.32604/jrm.2022.02045910.32604/jrm.2022.020459 ↗
4. 10.1021/acsapm.1c0171210.1021/acsapm.1c01712 ↗
5. 10.1080/17480272.2021.192356710.1080/17480272.2021.1923567 ↗
6. ISO 22007-2 2015. Plastics - determination of thermal conductivity and thermal diffusivity Part 2: transient plane heat source (hot disc) method.
7. 10.3732/ajb.080024810.3732/ajb.0800248 ↗
8. 10.1021/acssuschemeng.7b0351810.1021/acssuschemeng.7b03518 ↗
9. 10.1007/s13196-022-00289-510.1007/s13196-022-00289-5 ↗
10. 10.1021/acsomega.0c0577810.1021/acsomega.0c05778 ↗
11. 10.1016/j.porgcoat.2022.10684810.1016/j.porgcoat.2022.106848 ↗
12. 10.1007/s10853-007-1781-910.1007/s10853-007-1781-9 ↗
13. 10.3390/ma1320447810.3390/ma13204478 ↗
14. Liu, Y.X., and Zhao, G.J., 2004. Wood resource materials science. Bei Jing: China Forestry Publishing House.
15. 10.1080/17480272.2014.97057410.1080/17480272.2014.970574 ↗
16. 10.1515/hf-2015-022810.1515/hf-2015-0228 ↗
17. 10.1007/s00107-019-01401-210.1007/s00107-019-01401-2 ↗
18. 10.1007/s00107-010-0504-010.1007/s00107-010-0504-0 ↗
19. Qian, L.J., 2021. Modern flame retardant materials and technology. Bei Jing: Chemical Industry Press.
20. 10.19531/j.issn1001-5299.20200600210.19531/j.issn1001-5299.202006002 ↗
21. Tang Y. 2007. Study on the formaldehyde-free flame retardant wood particleboard and its adhesive. Dissertation Sichuan University.
22. 10.3390/ma1203041610.3390/ma12030416 ↗
23. 10.1080/02773813.2010.48646310.1080/02773813.2010.486463 ↗
24. 10.1007/s10570-021-04238-210.1007/s10570-021-04238-2 ↗
25. 10.1016/j.foreco.2021.11933010.1016/j.foreco.2021.119330 ↗
26. 10.1007/s00226-014-0671-y10.1007/s00226-014-0671-y ↗
27. 10.1002/pat.516510.1002/pat.5165 ↗
28. 10.1016/j.indcrop.2021.11436110.1016/j.indcrop.2021.114361 ↗
29. Zhang, X.T., et al., 2015. Synthesis of N-P fire retardant modified with MH and flame retardance and smoke suppression of poplar impregnated by it. New Chemical Materials, 43, 126–129.
30. 10.1016/j.conbuildmat.2023.13247010.1016/j.conbuildmat.2023.132470 ↗
31. 10.1155/2014/86710610.1155/2014/867106 ↗