Embedment strength and foundation modulus at an angle to the grain for fully threaded bolts
Source abstract
Abstract
As the main parameter, embedment strength is used to assess the load-carrying capacity of timber joints with dowel-type fasteners and foundation modulus is used to assess their stiffness. The embedment properties, i.e. embedment strength and foundation modulus, are system properties, which depend not only upon the material properties but also upon the load-to-grain angle and surface conditions of fasteners. The formulae for the embedment strengths of dowels and bolts in the design standards of timber structures are almost exclusively derived from the embedment tests on smooth dowels, with the surface conditions different from those of alternative fully threaded bolts in timber structures. Moreover, there are hardly any formulae for determining the foundation modulus. In this study, the embedment tests at different angles to the grain were carried out using the fully threaded bolts with different diameters in oversized holes as they would be used in practice. The load-to-grain angle had statistically significant effects on these embedment properties. The empirical formulae for the embedment strength and foundation modulus were derived. The embedment tests on fully threaded bolts and smooth dowels in tight-fitting holes were also performed to explore the effects of bolt hole sizes and surface conditions.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Geotechnical and Geomechanical Engineering · Engineering Structural Analysis Methods · Soil Mechanics and Vehicle Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian, People’s Republic of China
Department of Civil Engineering and Environmental Management, School of Computing, Engineering and Built Environment, Glasgow Caledonian University, Glasgow, UK
Funding
Natural Science Foundation of Liaoning Province
References (27)
Show source-provided references
1. ASTM, 2017. ASTM D2395-17 standard test methods for density and specific gravity (relative density) of wood and wood-based materials. West Conshohocken, PA: American Society for Testing and Materials (ASTM).
2. ASTM, 2018. ASTM D5764-97a standard test method for evaluating dowel-bearing strength of wood and wood-based products. West Conshohocken, PA: American Society for Testing and Materials (ASTM).
3. AWC, 2018. The national design specification (NDS) for wood construction with commentary. Leesburg, VA: American Wood Council (AWC).
4. Bleron, L. and Duchanois, G., 2006. Angle to the grain embedding strength concerning dowel type fasteners. Forest Products Journal, 56 (3), 44–50.
5. Bodig, J. and Jayne, B.A., 1982. Mechanics of wood and wood composites. New York: Van Nostrand Reinhold Company.
6. CEN, 2004. EN 1995-1-1 Eurocode 5 design of timber structures part 1-1: general rules and rules for buildings. Brussels: European Committee for Standardization (CEN).
7. CEN, 2007. EN 383 timber structures-test methods-determination of embedment strength and foundation values for dowel type fasteners. Brussels: European Committee for Standardization (CEN).
8. 10.1680/stbu.2010.163.4.25710.1680/stbu.2010.163.4.257 ↗
9. Ehlbeck J. and Werner H. 1992. Softwood and hardwood embedding strength for dowel type fasteners. In: CIB-W18 meeting 25 24–27 August 1992 Åhus Sweden.
10. Franke S. and Magnière N. 2014a. Discussion of testing and evaluation methods for the embedment behaviour of connections. In: INTER meeting 47 1–4 September 2014 Bath UK.
11. 10.1007/978-94-007-7811-5_2110.1007/978-94-007-7811-5_21 ↗
12. Glisovic, I., Stevanovic, B., and Kocetov-Misulic, T., 2012. Embedment test of wood for dowel-type fasteners. Wood Research, 57 (4), 639–650.
13. Hübner U. Bogensperger T. and Schickhofer G. 2008. Embedding strength of European hardwoods. In: CIB-W18 meeting 41 24–28 August 2008 St. Andrews Canada.
14. Johansen, K.W., 1949. Theory of timber connections. International Association of Bridge and Structural Engineering, 9, 249–262.
15. 10.1007/s00107-013-0718-z10.1007/s00107-013-0718-z ↗
16. 10.1111/j.1475-1305.2008.00570.x10.1111/j.1475-1305.2008.00570.x ↗
17. 10.1007/BF0076729110.1007/BF00767291 ↗
18. 10.1016/j.conbuildmat.2017.06.01510.1016/j.conbuildmat.2017.06.015 ↗
19. 10.1016/j.conbuildmat.2016.09.05110.1016/j.conbuildmat.2016.09.051 ↗
20. Schweigler M. et al. 2019. Embedment test analysis and data in the context of phenomenological modeling for dowelled timber joint design. In: INTER meeting 52 26–29 August 2019 Tacoma WA USA.
21. Serrano E. and Sjödin J. 2007. Dowel type joints – influence of moisture changes and dowel surface smoothness. In: COST action E55 4–5 October 2007 Eindhoven Netherlands.
22. 10.1007/s00107-008-0267-z10.1007/s00107-008-0267-z ↗
23. Whale L.R.J. Smith I. and Larsen H.J. 1987. Design of nailed and bolted joints proposals for the revision of existing formulae in draft Eurocode 5 and the CIB code. In: CIB-W18 meeting 20 September 1987 Dublin Ireland.
24. Wilkinson, T.L., 1991. Dowel bearing strength. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
25. 10.1007/s00107-022-01901-810.1007/s00107-022-01901-8 ↗
26. 10.1061/(ASCE)MT.1943-5533.000359910.1061/(ASCE)MT.1943-5533.0003599 ↗
27. 10.1002/pse.21310.1002/pse.213 ↗