journal article·2025-01-02

New reinforcements combining a steel plate and screws to enhance beam-column contact surfaces for prestressed timber joints

Yong Zhao, Jing Zhao, Hai-Rong Shi, Chun-Lin Wang

Publisher page

Abstract

The beam-column contact surface of joints in prestressed timber frames is one of the key factors determining structural performance. In this paper, a new reinforcement combining a steel plate and screws was proposed, and the effect of the reinforcements on the performance of joints was investigated by quasistatic tests for 5 beam-column edge joints. First, compared with the conventional joint, the joints reinforced by the steel plate and screws had an average increase in capacity of 25.8% and an average reduction in the degradation rate of the secant stiffness of 14.5%, which were beneficial for resisting repetitive loading. Then, the rate of the final prestressing loss and residual drift of the joint reinforced by the flat steel plate and screws were reduced by 20.5% and 85.7%, respectively, compared with those of the conventional joint. The enhancement effect of the reinforcement combining a U-shaped steel plate and screws was difficult to realize due to the susceptibility to the initial clearance. Finally, the mechanical mechanism of the new reinforcement was clarified, and a method for calculating the compression zone height of the beam in joints with the reinforcement was suggested, which improved the calculation accuracy by 13.7%.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Wood Treatment and Properties · Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Southeast University

Funding

Carbon Emission Peak and Carbon Neutrality Innovative Science Foundation of Jiangsu Province · National Natural Science Foundation of China

References (31)

Show source-provided references
1. American Society for Testing and Materials 2011. ASTM E2126-11 Standard test methods for cyclic (reversed) load test for shear resistance of vertical elements of the lateral force resisting systems for buildings United States.
2. Armstrong, T.W.N., 2015 Design of connections for post tensioned rocking timber frames. Canterbury: University of Canterbury.
3. 10.1016/j.engstruct.2016.11.06610.1016/j.engstruct.2016.11.066 ↗
4. Deutsches Institut für Bautechnik 2013. European Technical Approval ETA-11/0190 Germany.
5. 10.1080/1363246090285913610.1080/13632460902859136 ↗
6. European committee for standardization 2004. EN 1995-1-1 Eurocode 5: Design of Timber Structures - Part 1-1: General - Common rules and rules for buildings. Belgium.
7. He, M., et al., 2015. Effect of bolt row and self-tapping screw reinforcement on lateral performance of bolted timber connection. Journal of Tongji University (Natural Science), 43, 845–852.
8. 10.12989/eas.2016.10.2.40910.12989/eas.2016.10.2.409 ↗
9. Iqbal, M.A., 2011 Seismic response and design of subassemblies for multi-storey prestressed timber buildings. Canterbury: University of Canterbury.
10. Iqbal, A., Pampanin, S., and Buchanan, A., 2010. Seismic performance of prestressed timber beam-column sub-assemblies. New Zealand Society of Earthquake Engineering Conference.
11. 10.1016/j.compstruct.2021.11361210.1016/j.compstruct.2021.113612 ↗
12. Kurama, Y., et al., 1999. Lateral load behavior and seismic design of unbonded post-tensioned precast concrete walls. Structural Journal, 96, 622–632.
13. 10.1061/(ASCE)ST.1943-541X.000201210.1061/(ASCE)ST.1943-541X.0002012 ↗
14. Ministry of housing and urban-rural development of the people's republic of China, 2015. JGJ/T 101-2015 Specification for seismic test of buildings. Beijing: China Architecture & Building Press.
15. National Forestry and Grassland Administration, 2014. LY/T 2377-2014 test methods for the joint performance with dowel type fasteners used in wooden structural material. Beijing: China Architecture & Building Press.
16. Newcombe, M.P., et al., 2008a. Seismic design and numerical validation of post-tensioned timber frames. In: The 14th world conference on earthquake engineering .
17. 10.1080/1363246080192563210.1080/13632460801925632 ↗
18. Newcombe M.P. 2011 Seismic design of post-tensioned timber frame and wall buildings. University of Canterbury. Canterbury.
19. Newcombe, M.P., Pampanin, S., and Buchanan, A., 2010. Global response of a two storey Pres-Lam timber building. In: New Zealand society for earthquake engineering conference.
20. Palermo, A., et al., 2005. Seismic design of multi-storey buildings using laminated veneer lumber (LVL). In: New Zealand society of earthquake engineering conference.
21. Palermo, A., et al., 2006. Quasi-static cyclic tests on seismic-resistant beam-to-column and column-to-foundation subassemblies using Laminated Veneer Lumber (LVL). In: 19th Australasian conference on mechanics of structures and materials.
22. Palermo, A. and Pampanin, S., 2008. Analysis and simplified design of precast jointed ductile connections. In: The 14th world conference on earthquake engineering.
23. Pino, D., et al., 2010. Shake table response of multi-storey post-tensioned timber buildings. In: New Zealand society for earthquake engineering conference.
24. 10.15554/pcij.01011993.58.6910.15554/pcij.01011993.58.69 ↗
25. 10.1016/j.engstruct.2021.11276210.1016/j.engstruct.2021.112762 ↗
26. Smith T. 2014 Post-tensioned timber frames with supplemental damping devices. Canterbury: University of Canterbury.
27. 10.1016/j.engstruct.2015.01.04010.1016/j.engstruct.2015.01.040 ↗
28. Wang, M., et al., 2019. Bolted glulam beam-column connections under different combinations of shear and bending. Engineering Structures, 181, 281–292.10.1016/j.engstruct.2018.12.024 ↗
29. 10.1016/j.engstruct.2014.03.04210.1016/j.engstruct.2014.03.042 ↗
30. Wanninger, F. and Frangi, A., 2014b. Materials and joints in timber structures. Materials and Joints in Timber Structures, 9, 57–66.
31. 10.1016/j.engstruct.2016.01.02910.1016/j.engstruct.2016.01.029 ↗