Electrochemical and surface analyses of nanostructured Ti–24Nb–4Zr–8Sn alloys in simulated body solution
Source abstract
Abstract
The use of nanostructuring to improve the stability of passive thin films on biomaterials can enhance their effectiveness in corrosion resistance and reduce the release of ions. The thickness of the ultrathin films that cover Ti and Ti alloys (only several nanometers) has prevented researchers from establishing systematic methods for their characterization. This study employed a multifunctional biomedical titanium alloy Ti-24Nb-4Zr-8Sn (wt.%) as a model material. Coarse-grained (CG) and nanostructured (NS) alloys were analyzed in 0.9% NaCl solution at 37°C. To reveal the details of the passive film, a method of sample preparation producing a passive layer suitable for transmission electron microscope analysis was developed. Electrochemical corrosion behavior was evaluated by potentiodynamic polarization tests and Mott-Schottky measurements. Surface depth chemical profile and morphology evolution were performed by X-ray photoelectron spectroscopy and in situ atomic force microscopy, respectively. A mechanism was proposed on the basis of the point defect model to compare the corrosion resistance of the passive film on NS and CG alloys. Results showed that the protective amorphous film on NS alloy is thicker, denser and more homogeneous with fewer defects than that on CG alloy. The film on NS alloy contains more oxygen and corrosion-resistant elements (Ti and Nb), as well as their suboxides, compared with the film on CG alloy. These characteristics can be attributed to the rapid, uniform growth of the passive film facilitated by nanostructuring.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (61)
Show source-provided references
1. Corrosion fatigue of biomedical metallic alloys: mechanisms and mitigation10.1016/j.actbio.2011.09.012 ↗
2. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review10.1016/j.pmatsci.2008.06.004 ↗
3. Corrosion behavior of Ti–13Nb–13Zr alloy used as a biomaterial10.1016/j.jallcom.2008.09.026 ↗
4. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
5. In situ surface electrochemical characterizations of Ti and Ti–6Al–4V alloy cultured with osteoblast-like cells10.1016/j.bbrc.2003.12.173 ↗
6. Mechanical behavior of nanocrystalline metals and alloys10.1016/j.actamat.2003.08.032 ↗
7. The effects of grain size and porosity on the elastic modulus of nanocrystalline materials10.1016/S0965-9773(99)00052-5 ↗
8. The effect of SMAT-induced grain refinement and dislocations on the corrosion behavior of Ti–25Nb–3Mo–3Zr–2Sn alloy10.1016/j.msec.2013.01.068 ↗
9. Effect of equal channel angular extrusion on wear and corrosion behavior of the orthopedic Ti–13Nb–13Zr alloy in simulated body fluid10.1016/j.msec.2012.01.022 ↗
10. Effect of nanocrystalline phase on the electrochemical behavior of the alloy Ti60Ni4010.1016/j.jallcom.2012.06.007 ↗
11. Effect of surface nanocrystallization on the corrosion behavior of Ti–6Al–4V titanium alloy10.1016/j.surfcoat.2013.02.052 ↗
12. Enhanced osteoblast response to an equal channel angular pressing-processed pure titanium substrate with microrough surface topography10.1016/j.actbio.2009.04.038 ↗
13. Nanocrystalline beta-Ti alloy with high hardness, low Young’s modulus and excellent in vitro biocompatibility for biomedical applications10.1016/j.msec.2013.04.044 ↗
14. Elemental ion release from four different fixed prosthodontic materials10.1016/j.dental.2009.02.004 ↗
15. Point defect model and corrosion of anodic oxide coatings on Ti–6Al–4V10.1016/j.corsci.2008.02.023 ↗
16. The electrochemical behavior and passivity of titanium10.1149/1.2427492 ↗
17. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy10.1016/S0142-9612(00)00145-9 ↗
18. Surface characterization of passive film on NiCr-based dental casting alloys10.1016/S0142-9612(02)00544-6 ↗
19. In situ impedance spectroscopy study of the electrochemical corrosion of Ti and Ti–6Al–4V in simulated body fluid at 25°C and 37°C10.1016/j.corsci.2009.06.035 ↗
20. Properties of passive film formed on CP titanium, Ti–6Al–4V and Ti–13.4Al–29Nb alloys in simulated human body conditions10.1016/j.intermet.2004.10.001 ↗
21. Electrolytic breakdown crystallization of anodic oxide films on Al, Ta and Ti10.1016/0013-4686(70)80064-0 ↗
22. Transmission electron microscopy (TEM) on oxide layers formed on D9 stainless steel in lead bismuth eutectic (LBE)10.1016/j.corsci.2012.09.019 ↗
23. Super-elastic titanium alloy with unstable plastic deformation10.1063/1.2037192 ↗
24. Elastic deformation behaviour of Ti-24Nb–4Zr–7.9Sn for biomedical applications10.1016/j.actbio.2006.11.002 ↗
25. Early effect of Ti–24Nb–4Zr–7.9Sn intramedullary nails on fractured bone10.1016/j.msec.2008.08.019 ↗
26. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E ↗
27. The bone tissue compatibility of a new Ti–Nb–Sn alloy with a low Young’s modulus10.1016/j.actbio.2011.02.008 ↗
28. Effects of alloying elements on the cytotoxic response of titanium alloys10.1016/j.msec.2010.12.013 ↗
29. Ductile titanium alloy with low poisson’s ratio10.1103/PhysRevLett.98.216405 ↗
30. Effect of heat treatment and Sn content on superelasticity in biocompatible TiNbSn alloys10.2320/matertrans.43.2978 ↗
31. Effect of Zr and Sn on Young’s modulus and superelasticity of Ti–Nb-based alloys10.1016/j.msea.2006.09.051 ↗
32. Thermal stability and mechanical properties of nanostructured Ti–24Nb–4Zr–7.9Sn alloy10.1016/j.msea.2007.06.070 ↗
33. Phase stability and elastic modulus of Ti alloys containing Nb, Zr, and/or Sn from first-principles calculations10.1063/1.2988270 ↗
34. Effect of grain refinement on fibroblast adhesion and proliferation to Ti–24Nb–4Zr–7.9Sn alloy
35. Investigation on passivity of titanium under steady-state conditions in acidic solutions10.1016/j.matchemphys.2010.12.028 ↗
36. Electrochemical and passive characterization of a beta type Ti45Zr38Al17 cast rod in nitric acid medium10.1016/j.electacta.2012.08.047 ↗
37. High dielectric constant oxides10.1051/epjap:2004206 ↗
38. Corrosion behaviour of nanocrystalline 304 stainless steel prepared by equal channel angular pressing10.1016/j.corsci.2011.08.049 ↗
39. Nanocrystalline structure and nanopore formation in modified thermal TiO2 films10.1016/j.ijhydene.2006.09.025 ↗
40. The influence of growth-rate on the properties of anodic oxide-films on Titanium10.1016/0013-4686(89)87033-1 ↗
41. The influence of the growth rate on the semiconductive properties of titanium anodic oxide films10.1016/S0010-938X(98)00032-8 ↗
42. XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank’s physiological solution10.1016/j.electacta.2007.12.041 ↗
43. Reducibility of oxides and sulfides in metallurgical processes
44. Representation of mixed reactive gases on free energy (Ellingham–Richardson) diagrams10.1007/BF02915078 ↗
45. Influence of nanocrystallization on pitting corrosion behavior of an austenitic stainless steel by stochastic approach and in situ AFM analysis10.1016/j.electacta.2009.11.088 ↗
46. Passive film growth mechanism of nanocrystalline 304 stainless steel prepared by magnetron sputtering and deep rolling techniques10.1016/j.electacta.2011.05.106 ↗
47. Impact of amorphous titanium oxide film on the device stability of Al/TiO2/Al resistive memory10.1007/s00339-011-6278-3 ↗
48. Enhanced mechanical properties and in vitro corrosion behavior of amorphous and devitrified Ti40Zr10Cu38Pd12 metallic glass10.1016/j.jmbbm.2011.05.028 ↗
49. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution10.1016/S0142-9612(03)00252-7 ↗
50. Electrochemical corrosion of metallic biomaterials10.1016/0142-9612(84)90046-2 ↗
51. Effects of Nb and Zr alloying additions on the activation behavior of Ti in hydrochloric acid10.1149/1.1392655 ↗
52. Corrosion and passivity of Ti–13% Nb–13% Zr in comparison to other biomedical implant alloys10.5006/1.3290281 ↗
53. The corrosion behavior of Fe–10Cr nanocrystalline coating10.1016/j.electacta.2005.12.015 ↗
54. The improvement of the corrosion resistance of 309 stainless steel in the transpassive region by nano-crystallization10.1016/j.electacta.2008.08.073 ↗
55. Enhanced in vitro biocompatibility of ultrafine-grained biomedical NiTi alloy with microporous surface10.1016/j.apsusc.2011.05.105 ↗
56. Corrosion resistance and biocompatibility of Ti–Ta alloys for biomedical applications10.1016/j.msea.2005.03.032 ↗
57. Electrochemical corrosion behavior of nanocrystalline Co coatings explained by higher grain boundary density10.1016/j.electacta.2006.12.009 ↗
58. Grain size effects on the corrosion behavior of Ni50.5Ti49.5 and Ni45.6Ti49.3Al5.1 films10.1016/j.jelechem.2008.02.020 ↗
59. Effective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application10.1016/j.actbio.2011.10.018 ↗
60. Passivity – the key to our metals-based civilization10.1351/pac199971060951 ↗
61. The history of the point defect model for the passive state: a brief review of film growth aspects10.1016/j.electacta.2010.11.005 ↗