journal article·2011-11

Mechanical behaviour of synthetic surgical meshes: Finite element simulation of the herniated abdominal wall

B. Hernández-Gascón, E. Peña, H. Melero, G. Pascual, M. Doblaré, M.P. Ginebra, J.M. Bellón, B. Calvo

Acta Biomaterialia· Volume 7· Issue 11
Publisher page

Abstract

The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Hernia repair and management · Pelvic and Acetabular Injuries · Elasticity and Material Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Ambulatory outpatient hernia surgery including a new concept introducing tension-free repair
2. The tension-free hernioplasty10.1016/0002-9610(89)90526-6 ↗
3. Elasticity of the anterior abdominal wall and impact for reparation of incisional hernia using mesh implants
4. Anisotropy of human linea alba: a biomechanical study10.1016/j.jss.2004.10.010 ↗
5. Mechanical and histological characterization of the abdominal muscle: a previous step to model hernia surgery10.1016/j.jmbbm.2010.11.012 ↗
6. The lightweight and large porous mesh concept for hernia repair10.1586/17434440.2.1.103 ↗
7. Experimental comparison of monofile light and heavy polypropylene meshes: less weight does not mean less biological response10.1007/s00268-006-0670-8 ↗
8. Textile analysis of heavy-weight, mid-weight and light-weight polypropylene mesh in a porcine ventral hernia model10.1016/j.jss.2006.05.022 ↗
9. Mechanical properties of polypropylene mesh used in pelvic floor repair10.1007/s00192-007-0446-1 ↗
10. Early tissue incorporation and collagen deposition in lightweight polypropylene meshes: bioassay in an experimental model of ventral hernia10.1016/j.surg.2008.04.005 ↗
11. Role of the new lightweight prostheses in improving hernia repair10.1016/j.ciresp.2009.01.012 ↗
12. A new technique for the repair of inguinal and incisional hernias10.1001/archsurg.1960.01300050169030 ↗
13. The single-staged approach to the surgical management of abdominal wall hernias in contaminated fields10.1007/s10029-006-0164-5 ↗
14. Impact of polymer pore size on the interface scar formation in a rat model10.1006/jsre.2002.6358 ↗
15. Individual inflammatory response of human blood monocyte to mesh biomaterials10.1002/bjs.4023 ↗
16. Anisotropic evaluation of synthetic surgical meshes
17. Comparing the behavior of different polypropylene meshes (heavy and lightweight) in an experimental model of ventral hernia repair10.1002/jbm.b.31234 ↗
18. Normal intraabdominal pressure in healthy adults10.1016/j.jss.2005.06.015 ↗
19. Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery10.1007/s00464-005-0676-6 ↗
20. Functional and morphological evaluation of a low-weight monofilament polypropylene mesh for hernia repair10.1002/jbm.10119 ↗
21. Theory of invariants
22. Finite element implementation of incompressible transversely isotropic hyperelasticity10.1016/0045-7825(96)01035-3 ↗
23. A new constitutive framework for arterial wall mechanics and a comparative study of material models10.1023/A:1010835316564 ↗
24. Computational modelling of diarthrodial joints. Physiological, pathological and pos-surgery simulations,10.1007/s11831-006-9001-3 ↗
25. Holzapfel · 2000
26. A stress–strain relation for a rat abdominal aorta10.1016/0021-9290(88)90143-1 ↗
27. Using finite strain 3D-material models in beam and shell elements10.1108/02644400210450341 ↗
28. An algorithm for least-squares estimation of nonlinear parameters10.1137/0111030 ↗
29. Conze · 1999