Fatigue performance of auxetic meta-biomaterials

H.M.A. Kolken, A. Fontecha Garcia, A. Du Plessis, C. Rans, M.J. Mirzaali, A.A. Zadpoor

Acta Biomaterialia· Volume 126

Abstract

Meta-biomaterials offer a promising route towards the development of life-lasting implants. The concept aims to achieve solutions that are ordinarily impossible, by offering a unique combination of mechanical, mass transport, and biological properties through the optimization of their small-scale geometrical and topological designs. In this study, we primarily focus on auxetic meta-biomaterials that have the extraordinary ability to expand in response to axial tension. This could potentially improve the longstanding problem of implant loosening, if their performance can be guaranteed in cyclically loaded conditions. The high-cycle fatigue performance of additively manufactured (AM) auxetic meta-biomaterials made from commercially pure titanium (CP-Ti) was therefore studied. Small variations in the geometry of the re-entrant hexagonal honeycomb unit cell and its relative density resulted in twelve different designs (relative density: ~5–45%, re-entrant angle = 10–25°, Poisson's ratio = -0.076 to -0.504). Micro-computed tomography, scanning electron microscopy and mechanical testing were used to respectively measure the morphological and quasi-static properties of the specimens before proceeding with compression-compression fatigue testing. These auxetic meta-biomaterials exhibited morphological and mechanical properties that are deemed appropriate for bone implant applications (elastic modulus = 66.3–5648 MPa, yield strength = 1.4–46.7 MPa, pore size = 1.3–2.7 mm). With an average maximum stress level of 0.47 σy at 106 cycles (range: 0.35 σyσy- 0.82 σyσy), the auxetic structures characterized here are superior to many other non-auxetic meta-biomaterials made from the same material. The optimization of the printing process and the potential application of post-processing treatments could improve their performance in cyclically loaded settings even further. Auxetic meta-biomaterials have a negative Poisson's ratio and, therefore, expand laterally in response to axial tension. Recently, they have been found to restore bone-implant contact along the lateral side of a hip stem. As a result, the bone will be compressed along both of the implant's contact lines, thereby actively reducing the risk of implant failure. In this case the material will be subjected to cyclic loading, for which no experimental data has been reported yet. Here, we present the first ever study of the fatigue performance of additively manufactured auxetic meta-biomaterials based on the re-entrant hexagonal honeycomb. These results will advance the adoption of auxetic meta-biomaterials in load-bearing applications, such as the hip stem, to potentially improve implant longevity.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Cellular and Composite Structures · Bone Tissue Engineering Materials · High-Velocity Impact and Material Behavior

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (79)

Show source-provided references
1. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 203010.1007/s11999-009-0834-6 ↗
2. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 203010.2106/00004623-200704000-00012 ↗
3. Additively manufactured metallic porous biomaterials based on minimal surfaces: a unique combination of topological, mechanical, and mass transport properties10.1016/j.actbio.2017.02.024 ↗
4. Mechanical meta-materials10.1039/C6MH00065G ↗
5. Rationally designed meta-implants: a combination of auxetic and conventional meta-biomaterials10.1039/C7MH00699C ↗
6. Auxetic mechanical metamaterials10.1039/C6RA27333E ↗
7. Das gesetz der transformation der knochen
8. Architected cellular materials: a review on their mechanical properties towards fatigue-tolerant design and fabrication10.1016/j.mser.2021.100606 ↗
9. Low-cycle fatigue behavior of 3D-printed metallic auxetic structure
10. Low fatigue dynamic auxetic lattices with 3D printable, multistable, and tuneable unit cells10.3389/fmats.2018.00045 ↗
11. Fatigue life of auxetic Re-entrant honeycomb structure
12. Mechanical behaviour of conventional and negative Poisson's ratio thermoplastic polyurethane foams under compressive cyclic loading10.1016/j.ijfatigue.2006.07.015 ↗
13. Dynamic properties of high structural integrity auxetic open cell foam10.1088/0964-1726/13/1/006 ↗
14. Mechanical performance of auxetic meta-biomaterials10.1016/j.jmbbm.2020.103658 ↗
15. Helsen · 2010
16. Biologically and mechanically biocompatible titanium alloys10.2320/matertrans.L-MRA2008828 ↗
17. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing10.1016/j.msec.2015.05.001 ↗
18. Effects of applied stress ratio on the fatigue behavior of additively manufactured porous biomaterials under compressive loading10.1016/j.jmbbm.2016.11.022 ↗
19. Mechanical performance of additively manufactured meta-biomaterials10.1016/j.actbio.2018.12.038 ↗
20. Fatigue behavior of porous biomaterials manufactured using selective laser melting10.1016/j.msec.2013.08.006 ↗
21. Relationship between unit cell type and porosity and the fatigue behavior of selective laser melted meta-biomaterials10.1016/j.jmbbm.2014.12.015 ↗
22. Fatigue performance of additively manufactured meta-biomaterials: the effects of topology and material type10.1016/j.actbio.2017.11.014 ↗
23. Hedayati · 2020
24. 3DSystems, Laserform ti gr1 (A), 2017.
25. X-ray microcomputed tomography in additive manufacturing: a review of the current technology and applications10.1089/3dp.2018.0060 ↗
26. A new method for the model-independent assessment of thickness in three-dimensional images10.1046/j.1365-2818.1997.1340694.x ↗
27. Numerical comparison of lattice unit cell designs for medical implants by additive manufacturing10.1080/17452759.2018.1491713 ↗
28. Accurate characterization of machine compliance for simple compression testing10.1007/BF02317861 ↗
29. I. Standard, ISO 13314: 2011 (E) (2011) Mechanical testing of metals—ductility testing—compression test for porous and cellular metals, Ref number ISO 13314(13314) 1-7.
30. Isolated and modulated effects of topology and material type on the mechanical properties of additively manufactured porous biomaterials10.1016/j.jmbbm.2017.12.029 ↗
31. Compression fatigue of a cellular Al alloy10.1016/S0921-5093(99)00147-1 ↗
32. Selective laser melting of lattice structures: a statistical approach to manufacturability and mechanical behavior10.1016/j.rcim.2017.06.006 ↗
33. Micro-CT-based improvement of geometrical and mechanical controllability of selective laser melted Ti6Al4V porous structures10.1016/j.msea.2011.06.045 ↗
34. Effects of build orientation and heat treatment on the microstructure and mechanical properties of selective laser melted Ti6Al4V lattice structures10.1016/j.addma.2014.12.008 ↗
35. Effect of process parameters on the surface roughness of overhanging structures in laser powder bed fusion additive manufacturing10.1016/j.procir.2016.02.347 ↗
36. Determination of geometrical factors in layerwise laser melting using optical process monitoring10.1016/j.optlaseng.2011.06.016 ↗
37. Surface roughness effects on the fatigue strength of additively manufactured Ti-6Al-4V10.1016/j.ijfatigue.2018.07.013 ↗
38. From microstructural design to surface engineering: a tailored approach for improving fatigue life of additively manufactured meta-biomaterials10.1016/j.actbio.2018.10.043 ↗
39. Improving the fatigue performance of porous metallic biomaterials produced by Selective Laser Melting10.1016/j.actbio.2016.10.005 ↗
40. Surface post-treatments for metal additive manufacturing: progress, challenges, and opportunities
41. Application of mechanical surface finishing processes for roughness reduction and fatigue improvement of additively manufactured Ti-6Al-4V parts10.1016/j.ijfatigue.2017.05.008 ↗
42. The influence of porosity on fatigue crack initiation in additively manufactured titanium components10.1038/s41598-017-06504-5 ↗
43. The effects of microporosity in struts of gyroid lattice structures produced by laser powder bed fusion10.1016/j.matdes.2020.108899 ↗
44. Material defects as the basis of fatigue design10.1016/j.ijfatigue.2011.12.001 ↗
45. Gibson · 1999
46. Non-auxetic mechanical metamaterials10.3390/ma12040635 ↗
47. Additively manufactured space-filling meta-implants10.1016/j.actbio.2021.02.020 ↗
48. Foam topology: bending versus stretching dominated architectures10.1016/S1359-6454(00)00379-7 ↗
49. A parametric class of composites with a large achievable range of effective elastic properties10.1016/j.jmps.2018.05.018 ↗
50. The influence of cell morphology on the compressive fatigue behavior of Ti-6Al-4V meshes fabricated by electron beam melting10.1016/j.jmbbm.2016.01.034 ↗
51. Compression fatigue behavior of Ti–6Al–4V mesh arrays fabricated by electron beam melting10.1016/j.actamat.2011.10.051 ↗
52. Schijve · 2001
53. Enhanced fatigue characteristics of a topology-optimized porous titanium structure produced by selective laser melting
54. Effect of pore geometry on the fatigue properties and cell affinity of porous titanium scaffolds fabricated by selective laser melting10.1016/j.jmbbm.2018.08.048 ↗
55. Porosity of 3D biomaterial scaffolds and osteogenesis10.1016/j.biomaterials.2005.02.002 ↗
56. Bone tissue regeneration: the role of scaffold geometry10.1039/C4BM00291A ↗
57. Porous scaffolds for bone regeneration
58. High-strength porous biomaterials for bone replacement: a strategy to assess the interplay between cell morphology, mechanical properties, bone ingrowth and manufacturing constraints10.1016/j.actbio.2015.10.048 ↗
59. The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds10.1016/j.actbio.2012.04.001 ↗
60. Mechanical properties and in vitro behavior of additively manufactured and functionally graded Ti6Al4V porous scaffolds10.3390/met8040200 ↗
61. The effect of pore size and porosity on mechanical properties and biological response of porous titanium scaffolds10.1016/j.msec.2017.03.249 ↗
62. Architectural design of 3D printed scaffolds controls the volume and functionality of newly formed bone10.1002/adhm.201801353 ↗
63. On osseointegration in relation to implant surfaces10.1111/cid.12742 ↗
64. Role of implants surface modification in osseointegration: a systematic review10.1002/jbm.a.36829 ↗
65. Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells10.1002/(SICI)1097-4636(199609)32:1<55::AID-JBM7>3.0.CO;2-O ↗
66. Effects of build orientation on surface morphology and bone cell activity of additively manufactured Ti6Al4V specimens10.3390/ma11060915 ↗
67. Effects of bio-functionalizing surface treatments on the mechanical behavior of open porous titanium biomaterials10.1016/j.jmbbm.2014.04.010 ↗
68. Corrosion and surface modification on biocompatible metals: a review10.1016/j.msec.2017.04.102 ↗
69. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials
70. Producing and avoiding stress shielding: laboratory and clinical observations of noncemented total hip arthroplasty
71. How does tissue regeneration influence the mechanical behavior of additively manufactured porous biomaterials?10.1016/j.jmbbm.2016.10.003 ↗
72. Fabrication, pore structure and compressive behavior of anisotropic porous titanium for human trabecular bone implant applications10.1016/j.jmbbm.2015.02.023 ↗
73. S.A. Goldstein, The mechanical properties of trabecular bone: dependence on anatomic location and function, (1987).10.1016/0021-9290(87)90023-6 ↗
74. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
75. Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity10.1054/arth.2002.32699 ↗
76. The influence of osteoporosis in femoral fracture healing time10.1016/j.injury.2008.10.035 ↗
77. Compressive and fatigue behavior of beta-type titanium porous structures fabricated by electron beam melting10.1016/j.actamat.2016.12.052 ↗
78. Tuning the poisson's ratio of biomaterials for investigating cellular response10.1002/adfm.201202666 ↗
79. MG-63 osteoblast-like cell proliferation on auxetic PLGA scaffold with mechanical stimulation for bone tissue regeneration10.1186/s40824-016-0080-4 ↗