A new method for nondestructive evaluation of solid wood moisture content based on dual-energy X-ray absorptiometry
Source abstract
Abstract
This paper presents a new method to determine the moisture content of solid wood based on the principle of dual-energy X-ray absorptiometry. The study investigates the theoretical relationship between X-ray wavelength and mass attenuation coefficients of wood, water, and reference substance. In accordance with this relationship, a theoretically obtained equation is proposed to calculate the moisture content in wood. The proposed equation is compared to experimental results using small blocks of sugi wood, which showed that the change in mass attenuation coefficient of wood with X-ray tube voltage increased with increasing moisture content as expected from the theoretical equation. A regression equation for moisture content estimation was determined based on the experimental results, and the standard error of estimate in the 0–120 % dry-basis moisture content range using the regression equation was determined to be 21.9 % with the most appropriate pair of tube voltages, 15 and 40 kVp. The accuracy of the method will be improved by reducing the duration of X-ray radiography and by increasing the disparity between paired tube voltages. This method has the potential to determine moisture content of solid wood using X-ray without oven-drying or assuming oven-dry density.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Radiation Shielding Materials Analysis · Wood Treatment and Properties · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Hattori Y, Kanagawa Y (1985) Non-destructive measurement of moisture distribution in wood with a medical X-ray CT scanner I. Accuracy and influencing factors (in Japanese). Mokuzai Gakkaishi 31:974–982
2. Hultnäs M, Fernandez-Cano V (2012) Determination of the moisture content in wood chips of Scots pine and Norway spruce using Mantex Desktop Scanner based on dual energy X-ray absorptiometry. J Wood Sci 58:309–31410.1007/s10086-012-1260-z ↗
3. Ida T (2008) How to use powder diffraction method (2)—preparation of specimen—(in Japanese). J Flux Growth 3:2–6
4. Jackson DF, Hawkes DJ (1981) X-ray attenuation coefficients of elements and mixtures. Phys Rep 70:169–23310.1016/0370-1573(81)90014-4 ↗
5. Kato H (2010) X-ray spectrum (in Japanese). Jpn J Radiol Technol 66:238–24510.6009/jjrt.66.238 ↗
6. Kullenberg R, Hultnäs M, Fernandez V, Nylinder M, Toft S, Danielsson F (2010) Dual-energy X-ray absorptiometry analysis for the determination of moisture content in biomass. J Biobased Mater Bioenergy 4:363–36610.1166/jbmb.2010.1101 ↗
7. Lindgren LO (1991a) Medical CAT-scanning: X-ray absorption coefficients, CT-numbers and their relation to wood density. Wood Sci Technol 25:341–349
8. Lindgren LO (1991b) The accuracy of medical CAT-scan images for non-destructive density measurements in small volume elements within solid wood. Wood Sci Technol 25:425–432
9. Mazess RB, Barden HS, Bisek JP, Hanson J (1990) Dual-energy X-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition. Am J Clin Nutr 51:1106–111210.1093/ajcn/51.6.1106 ↗
10. Migita N (1968) Mokuzai no sosei (in Japanese). In: Migita N, Yonezawa Y, Kondo T (eds) Mokuzaikagaku. Kyoritsu Shuppan Co. Ltd., Tokyo, p 65
11. National Astronomical Observatory of Japan (2010) Chronological scientific tables 2011 (in Japanese). Maruzen Co. Ltd., Tokyo, p 446
12. Sartoris DJ, Resnick D (1989) Dual-energy radiographic absorptiometry for bone densitometry: current status and perspective. Am J Roentgenol 152:241–24610.2214/ajr.152.2.241 ↗
13. Tanaka T, Avramidis S, Shida S (2009) Evaluation of moisture content distribution in wood by soft X-ray imaging. J Wood Sci 55:69–7310.1007/s10086-008-0997-x ↗
14. Tawara Y (1999) X-ray tubes (in Japanese). In: Namioka T, Yamashita K (eds) X-ray imaging optics. Baifukan Co Ltd, Tokyo, pp 23–25
15. Watanabe K, Saito Y, Avramidis S, Shida S (2008) Non-destructive measurement of moisture distribution in wood during drying using digital X-ray microscopy. Dry Technol 26:590–59510.1080/07373930801944796 ↗