journal article·2023-07Open access

Thickness of zero-strength layer in timber beam exposed to fuel-controlled parametric fires

Sabina Huč, Tomaž Hozjan, Robert Pečenko

Wood Science and Technology· Volume 57· Issue 4

Abstract

Abstract Fire resistance is one of the essential requirements to be fulfilled in the design of timber structures. For this purpose, a reduced cross-section method is given in the European standards, Eurocodes. The method is based on the assumption that an initial, rectangular timber cross-section exposed to fire conditions reduces to an effective cross-section, which has material properties as at a room temperature. The reduced part of the cross-section with no resistance is determined by a sum of two parameters, namely a charring depth and a thickness of zero-strength layer. Eurocodes give a value of the latter only for the standard fire exposure, which is only one of the fire curves proposed in the same standards. Therefore, the present paper examines the thickness of zero-strength layer in case of 46 different fuel-controlled parametric fire exposures applied to a timber beam from three sides. A four-phase numerical analysis is applied for this purpose that includes the use of a hygro-thermal model and a mechanical model to determine temperatures of timber over the cross-section and the mechanical resistance of timber beam in fire conditions, respectively. The results show that the thickness of zero-strength layer takes the values between 7.9 and 18.4 mm for the fuel-controlled parametric fire exposures. Since it is clearly dependent on the parameters describing the parametric fire curve, five equations are proposed that can be used for determination of the thickness of zero-strength layer in case of parametric fire exposures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Fire dynamics and safety research · Wood Treatment and Properties · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Brandon D, Just A, Lange D, Tiso M, (2017) Parametric fire design – zero-strength-layers and charring rates. In: 4th meeting of INTER – international network on timber engineering research, 28–31, 2017, Kyoto, Japan
2. Bratina S, Saje M, Planinc I (2004) On materially and geometrically non-linear analysis of reinforced concrete planar frames. Int J Solids Struct 41:7181–7207. https://doi.org/10.1016/j.ijsolstr.2004.06.00410.1016/j.ijsolstr.2004.06.004 ↗
3. Cengel YA (1998) Heat transfer: a practical approach. WCB/McGraw-Hill, New York
4. Di Blasi C (1998) Multi-phase moisture transfer in the high-temperature drying of wood particles. Chem Eng Sci 53:353–366. https://doi.org/10.1016/S0009-2509(97)00197-810.1016/S0009-2509(97)00197-8 ↗
5. EN 338: Structural timber – Strength classes, European committee for standardization, Brussels, 2016
6. EN 1991–1–2, Eurocode 1: actions on structures - Part 1–2: general actions – actions on structures exposed to fire, European committee for standardization, Brussels, 2002
7. EN 1995–1–2, Eurocode 5: design of timber structures - Part 1–2: General - structural fire design, european committee for standardization, Brussels, 2005
8. Frangi A, König J (2011) Effect of increased charring on the narrow side of rectangular timber cross-sections exposed to fire on three or four sides. Fire Mater 35:593–605. https://doi.org/10.1002/fam.107810.1002/fam.1078 ↗
9. Gernay T, Franssen J-M (2015) A performance indicator for structures under natural fire. Eng Struct 100:94–103. https://doi.org/10.1016/j.engstruct.2015.06.00510.1016/j.engstruct.2015.06.005 ↗
10. Huč S, Pečenko R, Hozjan T (2021) Predicting the thickness of zero-strength layer in timber beam exposed to parametric fires. Eng Struct 229:111608. https://doi.org/10.1016/j.engstruct.2020.11160810.1016/j.engstruct.2020.111608 ↗
11. König J (2006) Effective thermal actions and thermal properties of timber members in natural fires. Fire Mater 30:51–63. https://doi.org/10.1002/fam.89810.1002/fam.898 ↗
12. Lange D, Boström L, Schmid J, Albrektsson J (2015) The Reduced Cross Section Method Applied to Glulam Timber Exposed to Non-standard Fire Curves. Fire Technol 51:1311–1340. https://doi.org/10.1007/s10694-015-0485-y10.1007/s10694-015-0485-y ↗
13. Lucherini A, Jovanović B, Van Coile R, Merci B (2021) Background and limitations of the Eurocode parametric fire curves, including the decay phase. Applications of Structural Fire Engineering, 10–11 June 2021, Ljubljana, Slovenia
14. Pečenko R, Hozjan T (2021) A novel approach to determine charring of wood in natural fire implemented in a coupled heat-mass-pyrolysis model. Holzforschung 75:148–158. https://doi.org/10.1515/hf-2020-008110.1515/hf-2020-0081 ↗
15. Pečenko R, Svensson S, Hozjan T (2015) Modelling heat and moisture transfer in timber exposed to fire. Int J Heat Mass Transf 87:598–605. https://doi.org/10.1016/j.ijheatmasstransfer.2015.04.02410.1016/j.ijheatmasstransfer.2015.04.024 ↗
16. Pečenko R, Svensson S, Hozjan T (2016) Model evaluation of heat and mass transfer in wood exposed to fire. Wood Sci Technol 50:727–737. https://doi.org/10.1007/s00226-016-0813-510.1007/s00226-016-0813-5 ↗
17. Pečenko R, Planinc I, Svensson S, Hozjan T (2019) Implementing coupled heat and moisture transfer model in the fire analysis of timber beams. Fire Safety J 107:170–178. https://doi.org/10.1016/j.firesaf.2018.11.00710.1016/j.firesaf.2018.11.007 ↗
18. Pečenko R (2016) Mechanical response of curved timber beams with variable height under fire conditions. Dissertation, University of Ljubljana
19. Reissner E (1972) On one-dimensional finite-strain beam theory: the plane problem. J Appl Math Phys (ZAMP) 23:795–804. https://doi.org/10.1007/BF0160264510.1007/BF01602645 ↗
20. Schmid J, König J, Just A (2012) The reduced cross-section method for the design of timber structures exposed to fire — background, limitations and new developments. Struct Eng Int 22:514–522. https://doi.org/10.2749/101686612X1336392951757810.2749/101686612X13363929517578 ↗
21. Schmid J, Klippel M, Just A, Frangi A (2014) Review and analysis of fire resistance tests of timber members in bending, tension and compression with respect to the reduced cross-section method. Fire Safety J 68:81–99. https://doi.org/10.1016/j.firesaf.2014.05.00610.1016/j.firesaf.2014.05.006 ↗
22. Schmid J, Just A, Klippel M, Fragiacomo M (2015) The reduced cross-section method for evaluation of the fire resistance of timber members: discussion and determination of the zero-strength layer. Fire Technol 51:1285–1309. https://doi.org/10.1007/s10694-014-0421-610.1007/s10694-014-0421-6 ↗
23. Šulc S, Šmilauer V, Patzák B et al (2019) Linked simulation for fire-exposed elements using CFD and thermo-mechanical models. Adv Eng Softw 131:12–22. https://doi.org/10.1016/j.advengsoft.2019.02.00710.1016/j.advengsoft.2019.02.007 ↗
24. Thi VD, Khelifa M, Oudjene M et al (2017) Finite element analysis of heat transfer through timber elements exposed to fire. Eng Struct 143:11–21. https://doi.org/10.1016/j.engstruct.2017.04.01410.1016/j.engstruct.2017.04.014 ↗
25. Tiso M, Just A, Schmid J, Klippel M (2018) Effective cross-sectional method for timber frame assemblies-definition of coefficients and zero-strength layers. Fire Mater 42:897–913. https://doi.org/10.1002/fam.264510.1002/fam.2645 ↗
26. Tiso M, Just A, Schmid J et al (2019) Evaluation of zero-strength layer depths for timber members of floor assemblies with heat resistant cavity insulations. Fire Safety J 107:137–148. https://doi.org/10.1016/j.firesaf.2019.01.00110.1016/j.firesaf.2019.01.001 ↗
27. Wiesner F, Bisby LA, Bartlett AI et al (2019) Structural capacity in fire of laminated timber elements in compartments with exposed timber surfaces. Eng Struct 179:284–295. https://doi.org/10.1016/j.engstruct.2018.10.08410.1016/j.engstruct.2018.10.084 ↗
28. Zhang Y, Zhang L, Shan Z et al (2019) Thermal responses of woods exposed to high temperatures considering apparent thermo-physical properties. J Renew Mater 7:1093–1107. https://doi.org/10.32604/jrm.2019.0733510.32604/jrm.2019.07335 ↗