journal article·2019-11

Microwave-induced thermoacoustic imaging of wood: a first demonstration

Dan Zhang, Hang He, Chujing Zong, Yunfei Liu

Wood Science and Technology· Volume 53· Issue 6
Publisher page

Abstract

Hollow decay is the main problem that affects healthy tree growth and significantly reduces the subsequent practical value of wood. In this work, for the first time, an effective microwave-induced thermoacoustic imaging technology adopted for wood specimens is proposed. The thermoacoustic principle combines microwaves and ultrasonic waves and relies on the microwave penetrating ability and high spatial resolution to generate an ultrasonic excitation source from wood. Thermal ultrasonic imaging technology and high imaging precision present the detection results rapidly, allowing quick, effective, and easy evaluation. This also is the first demonstration of wood microwave-induced thermoacoustic imaging.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Thermography and Photoacoustic Techniques · Photoacoustic and Ultrasonic Imaging · Ultrasonics and Acoustic Wave Propagation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
1. Anderson BE, Griffa M, Ulrich TJ, Johnson PA (2007) Improving spatial resolution of a time-reversed focus using frequency-domain signal processing. J Acoust Soc Am 122:3072
2. Arfken GB, Weber HJ (1995) Mathematical methods for physicists. Academic Press, San Diego
3. Bauer DR, Wang X, Vollin J, Xin H, Witte RS (2012) Spectroscopic thermoacoustic imaging of water and fat composition. Appl Phys Lett 101:03370510.1063/1.4737414 ↗
4. Bell AG (1880) On the production and reproduction of sound by light. Am J Sci 20:305–32410.2475/ajs.s3-20.118.305 ↗
5. Blomgren P, Papanicolaou G, Zhao H (2002) Super-resolution in time-reversal acoustics. J Acoust Soc Am 111:230–24810.1121/1.1421342 ↗
6. Chambers H, Berryman JG (2004) Analysis of the time-reversal operator for a small spherical scatterer in an electromagnetic field. IEEE Trans Antennas Propag 52:1729–173810.1109/TAP.2004.831323 ↗
7. Chen GP, Zhao ZQ, Zheng WJ, Nie ZP, Liu QH (2009) Application of time reversal mirror technique in microwave-induced thermo-acoustic tomography system. Sci China Ser E Technol Sci 52:2087–209510.1007/s11431-009-0148-7 ↗
8. Chen GP, Zhao ZQ, Liu QH (2012) The computational study of microwave-induced thermo-acoustic tomography for biologic tissue imaging based on pseudo-spectrum time domain and time reversal mirror technique. Appl Mech Mater 195:353–35910.4028/www.scientific.net/AMM.195-196.353 ↗
9. Chen G, Wang X, Liu QH (2013) Microwave-induced thermo-acoustic tomography system using TRM-PSTD technique. Progr Electromagn Res B 48:43–5910.2528/PIERB12111503 ↗
10. Deng ZG, Deng RB (1998) Microwave detection of plate defects. For Mach Woodwork Equip 6:30–31
11. Derode A, Roux P, Fink M (1995) Robust acoustic time reversal with high-order multiple scattering. Phys Rev Lett 75:4206–420910.1103/PhysRevLett.75.4206 ↗
12. Devaney AJ (2000) Super-resolution processing of multi-static data using time reversal and music. Preprint, Department of Electrical Engineering, Northeastern University, Boston, MA
13. Gamier J, Fouque JP, Solna K (2006) Time reversal super resolution in randomly layered media. Wave Motion 43:646–66610.1016/j.wavemoti.2006.06.002 ↗
14. Guo TC, Guo WW, Larsen LE (1984) Microwave-Induced thermoacoustic effect in dielectrics and its coupling to external medium—a thermodynamical formulation. IEEE Trans Microw Theory Tech 32:835–84310.1109/TMTT.1984.1132780 ↗
15. Hristova Y (2009) Time reversal in thermoacoustic tomography—an error estimate. Inverse Probl 25:5500810.1088/0266-5611/25/5/055008 ↗
16. Kellnberger S, Hajiaboli A, Razansky D, Ntziachristos V (2011) Near-field thermoacoustic tomography of small animals. Phys Med Biol 56:3433–344410.1088/0031-9155/56/11/016 ↗
17. Kruger RA, Kiser WL, Reinecke DR, Kruger GA, Eisenhart RL (1999a) Thermoacoustic computed tomography of the breast at 434 MHz. IEEE MTT-S Int Microw Symp Dig 2:591–594
18. Kruger RA, Kopecky KK, Aisen AM, Reinecke DR, Kruger GA, Kiser WL Jr (1999b) Thermoacoustic CT with radio waves: a medical imaging paradigm. Radiology 211:275–27810.1148/radiology.211.1.r99ap05275 ↗
19. Ku G, Wang LV (2001) Scanning microwave-induced thermoacoustic tomography: signal, resolution, and contrast. Med Phys 28:4–1010.1118/1.1333409 ↗
20. Lehman SK, Devaney AJ (2003) Transmission mode time-reversal super-resolution imaging. J Acoust Soc Am 113:2742–275310.1121/1.1566975 ↗
21. Li X, Bond EJ, Van Veen BD, Hagness SC (2005) An overview of ultra-wideband microwave imaging via space-time beamforming for early-stage breast-cancer detection. IEEE Antennas Propag Mag 47:19–3410.1109/MAP.2005.1436217 ↗
22. Lin JC (1980) The microwave auditory phenomenon. Proc IEEE 68:67–7310.1109/PROC.1980.11583 ↗
23. Lin JC (2005) Microwave thermoelastic tomography and imaging. Springer, New York10.1007/0-387-24024-1_2 ↗
24. Liu DH, Krolik J, Carin L (2007) Electromagnetic target detection in uncertain media: time-reversal and minimum-variance algorithms. IEEE Trans Geosci Remote Sens 45:934–94410.1109/TGRS.2006.890411 ↗
25. Meaney PM, Goodwin D, Golnabi AH et al (2012) Clinical Microwave tomographic imaging of the calcaneus: a first-in-human case study of two subjects. IEEE Trans Biomed Eng 59:3304–331310.1109/TBME.2012.2209202 ↗
26. Morse PM, Feshbach H (1953) Methods of theoretical physics. McGraw-Hill, New York
27. Norton SJ, Linzer M (1981) Ultrasonic reflectivity imaging in three dimensions: exact inverse scattering solutions for plane, cylindrical, and spherical apertures. IEEE Trans Biomed Eng 28:202–22010.1109/TBME.1981.324791 ↗
28. Olivito RS (1996) Ultrasonic measurements in wood. Mater Eval 54:514–517
29. Ostadrahimi M, Zakaria A, Lovetri J, Shafai L (2013) A near-field dual polarized (TE-TM) microwave imaging system. IEEE Trans Microw Theory Tech 61:1376–138410.1109/TMTT.2012.2237181 ↗
30. Rayleigh B, Strum JW (1896) The theory of sound, vol 2. Macmillan, London
31. Rosenthal A, Jetzfellner T, Razansky D, Ntziachristos V (2012) Efficient framework for model-based tomographic image reconstruction using wavelet packets. IEEE Trans Med Imaging 31:1346–135710.1109/TMI.2012.2187917 ↗
32. Ross RJ, Pellerin RF (1988) NDE of wood-based composites withlongitudinal stress wave. For Prod J 38:39–45
33. Scherzer O (2011) Handbook of mathematical methods in imaging. Springer, New York10.1007/978-0-387-92920-0 ↗
34. Tam AC (1986) Application of photoacoustic sensing techniques. Rev Mod Phys 58:381–43110.1103/RevModPhys.58.381 ↗
35. Wang JG, Zhao ZQ, Song J, Nie ZP, Liu QH (2013) Reconstruction of microwave absorption of multiple tumors in heterogeneous tissue for microwave-induced thermo-acoustic tomography. Progr Electromagn Res M 32:57–7210.2528/PIERM13051903 ↗
36. Xie Y, Guo B, Li J, Ku G, Wang LV (2008) Adaptive and robust methods of reconstruction (ARMOR) for thermoacoustic tomography. IEEE Trans Biomed Eng 55:2741–275210.1109/TBME.2008.919112 ↗
37. Xu MH, Wang LV (2002) Time-domain reconstruction for thermoacoustic tomography in a spherical geometry. IEEE Trans Med Imaging 21:814–82210.1109/TMI.2002.801176 ↗
38. Xu MH, Ku G, Wang LV (2001) Microwave-induced thermoacoustic tomography using multi-sector scanning. Med Phys 28:1958–196310.1118/1.1395037 ↗
39. Xu Y, Feng D, Wang LV (2002a) Exact frequency-domain reconstruction for thermoacoustic tomography. I. Planar geometry. IEEE Trans Med Imaging 21:823–82810.1109/TMI.2002.801172 ↗
40. Xu Y, Xu MH, Wang LV (2002b) Exact frequency-domain reconstruction for thermoacoustic tomography. II. Cylindrical geometry. IEEE Trans Med Imaging 21:829–83310.1109/TMI.2002.801171 ↗
41. Zheng WJ, Zhao ZQ, Nie ZP, Liu QH (2009) Evaluation of TRM in the complex through wall environment. Prog Electromagn Res 90:235–25410.2528/PIER09011003 ↗