Determining pore size distribution in wet earlywood cell wall by solute exclusion using total organic carbon technique (TOC)
Source abstract
Abstract
Solute exclusion is a probe technique useful to determine the pore volume and pore size distribution of a cell wall network; however, accurate measuring of molecular probe concentration is critical. In this study, the concentration of polyethylene glycol (PEG) and glucose was measured by detection of their organic carbon using a total organic carbon (TOC) equipment. PEG and glucose concentration by TOC is based on the quantitative oxidation of the organic matter contained in the solution, and then, produced CO₂is stoichiometrically correlated with the TOC value. In this work on Pinus radiata earlywood cell wall, the fiber saturation point was 0.72 mL/g and it was reached by a molecular probe size with a radius of gyration Rg = 5.96 Å. Moreover, the mean pore size present in the wood samples has a size equivalent to a molecular probe with a radius of gyration of 3.77 Å. Since TOC is based on the quantitative oxidation of the organic matter contained in the solution, it is essential to wash and rinse the wood samples to prevent that other carbon sources as extractives modify PEG and glucose concentration. Finally, the accuracy of TOC to determine the pore size distribution in the wet wood cell wall is subject to limitations of the solute exclusion technique.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Advanced Cellulose Research Studies · Lignin and Wood Chemistry
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Cosgrove DJ (2005) Growth of the plant cell wall. Nat Rev Mol Cell Biol 6:850–86110.1038/nrm1746 ↗
2. Erko M, Findenegg H, Cade N, Michette A, Paris O (2011) Confinement-induced structural changes of water studied by Raman scattering. Phys. Rev. B 84(104205):8
3. Harting C, Witschel W, Spohr E (1998) Molecular dynamics study of the structure and dynamics of water in cylindrical pores. J. Phys. Chem. B 102:1241–124910.1021/jp973018d ↗
4. Holyst R, Bielejewska A, Szymanski J, Wilk A, Patkowski A, Gapinski J, Zywocinski A, Kalwarczyk T, Kalwarczyk E, Tabaka M, Ziebacz N, Wieczorek S (2009) Scaling form of viscosity at all length-scales in poly (ethylene glycol) solutions studied by fluorescence correlation spectroscopy and capillary electrophoresis. Phys Chem Chem Phys 11:9025–903210.1039/b908386c ↗
5. Kawahigashi M, Fujitake N, Yajima H, Sumida H (2011) Particle sizes of standard humic substances calculated as radii of gyration, maximum diameter and hydrodynamic radii. Humic Subst Res 8(1):13–18
6. Lei YC, Zhang SY (2004) Features and partial derivatives of Bartalanffy-Richards growth model in forestry. Nonlinear anal model control 9(1):65–7310.15388/NA.2004.9.1.15171 ↗
7. Lin J, Ladish M, Patterson J, Noller C (1987) Determining pore size distribution in wet cellulose by measuring solute exclusion using a differential refractometer. Biotechnol Bioeng 24:976–98110.1002/bit.260290809 ↗
8. Lucia L, Rojas O (2009) The nanoscience and technology of renewable biomaterials, 1 edn. Wiley, pp 36610.1002/9781444307474 ↗
9. Maloney T, Paulapuro H (1999) The formation of pore in the cell wall. J Pulp Pap Sci 25(12):430–436
10. Meyers P (1998) Sources of TOC in Deionized water. IWC-98- 37 PSM.doc
11. Rondeau-Mouro C, Defer D, Leboeuf E, Lahaye M (2008) Assessment of cell wall porosity in Arabidopsis thaliana by NMR spectroscopy. Int J Biol Macromol 42:83–9210.1016/j.ijbiomac.2007.09.020 ↗
12. Van Dyke B (1972) Enzymatic hydrolysis of cellulose—a kinetics study. Ph. D. Dissertation, MIT, Cambridge
13. Visco G, Campanella L, Nobili V (2005) Organic carbons and TOC in waters: an overview of the international norm for its measurements. Microchem J 79:185–19110.1016/j.microc.2004.10.018 ↗
14. Weatherwax R (1977) Collapse of cell wall pores during drying of cellulose. J Colloid Interface Sci 62(3):423–44610.1016/0021-9797(77)90094-7 ↗